Transcription of D9412GV4 Control Panel
1 Intrusion Alarm Systems | D9412GV4 Control PanelD9412GV4 Control Panel uFully integrated intrusion, fire , and access controlallows users to interface with one system instead ofthreeuConettix IP based communication options providehigh speed, secure alarm transport and controlthrough connection of wired and/or cellular networkinterfacesuUp to 32 programmable areas, each supportingperimeter and interior points with your choice oftouch screen, ATM style, or LED keypadsu246 hardwired, addressable or wireless points withflexible configuration options to meet multipleinstallation requirementsuOPTIONAL GV4 version firmware upgradeavailableGV4 panels are the premier commercial Control panelline from Bosch.
2 GV4 panels integrate intrusion, fireand access Control providing one simple user interfacefor all systems. With the ability to adapt to large andsmall applications, the D9412GV4 provides up to 246individually identified points that can be split into 32areas. The Control Panel includes a communicator thatsends events to selected public switched telephonenetwork (PSTN), IP network, or cellular networkdestinations through four programmable route the D9412GV4 you can: Monitor alarm points for intruder or fire alarms whileoperating keypads and other outputs Program all system functions local or remote usingRemote Programming Software (RPS) or by usingbasic programming through the keypad.
3 Add up to eight doors of access Control using theoptional D9210C Access Control Interface outputs 2 A alarm power at 12 VDC A auxiliary power at 12 VDC Four alarm output patterns Programmable bell testSystem response High-performance micro controller providesindustry leading system response High-speed device bus 31 custom point indexes, including fire supervisory Selectable point response time Cross point capability fire alarm verification fire inspector s local test Watch mode Scheduled events (SKEDS) arm, disarm, bypass andunbypass points, Control relays, Control authoritylevels, and Control door accessUser interface Supervision of up to 16 keypads (up to 32unsupervised keypads can be used) Remote Programming Software (RPS)
4 Allows endusers to perform Control Panel management tasks Add/Delete/Change user passcodes and authorities,view and print the Panel history event log Custom keypad text is fully programmable, includingremote programming Full function command menu including CustomFunctions Authority by area and 16 character name for eachuser 14 custom authority levels Control user s authority tochange, add, or delete passcodes or access controlcredentials; to disarm or bypass points; and to startsystem testsArea configurationsArea programming offers a wide selection of differentsystem configurations. Each area is assigned anaccount number to define annunciation, Control , andreporting functions.
5 Multiple areas can be linked to ashared area which is automatically controlled (hallwayor lobby). Area arming can be conditional on otherareas (master or associate). Any area can beconfigured for perimeter and interior arming, notrequiring a separate area for this functionsFor added convenience, Custom Functions can beprogrammed to eliminate keystrokes for users allowingthe installer to program an easy command for acomplicate function. For example, a custom functioncan be written to bypass a group of points and armthe system, allowing the user to perform this functionwith one easy command. This can be used to Control aparticular room, or even a single door allowingcustomized access.
6 In additions, Custom Functionscan be activated with a token or card, or automaticallyas a scheduled event (SKED) providing furtherflexibility and ease of custom functionA custom function activates when user credentials arepresented to a B901 or D9210C access controlmodule s door controller's reader. The customfunction behaves as though the user performed afunction at the keypad associated with the securityFor high security applications, GV4 can be configuredfor several different passcode options. Dual Authentication requires a user to enter theirpasscode and also use a token or card. Two-Man Rule - Requires two people with two uniquepasscodes to be present at the time of opening.
7 Early Ambush - Allows users to verify that the facilityis safe by requiring two passcode entries at differentkeypads within the same area, sending a duress eventif the user does not enter the passcode a second timeafter inspecting the Exit controlThe Control Panel changes from one armed state toanother armed state without disarming. For example,if you change the state from Perimeter Arm to MasterArm, the Control Panel complies and reports thechange. Easy Exit Control reduces the number ofkeystrokes, simplifying system passcode-controlled Menu ListThe system prompts users to enter a passcode prior toviewing the keypad menu. The keypad display showsthe user the menu options allowed according to theuser s authority level.
8 Passcode-controlled menusprovide users only with the options and informationpertinent to them, simplifying system controlThe system provides the flexibility to select addedconvenience or high security. For example, you canrestrict passcode arming and disarming to a keypad'simmediate local area, even if the user has access toother areas. This is particularly useful for high securityareas, where a user may have access to the area, butwould prefer to only disarm the area individually ratherthan with the rest of the system. Another option is toprogram the system to disarm all areas the user canaccess from any walk testA menu item allows the user to test invisible 24-hourpoints within the scope of the keypad without sendinga report to the central usersThe system supports up to 1000 users, each can havea passcode, an access token and a wireless passcodes contain three to six digits.
9 Passcodescan be assigned to one of 14 customized authoritylevels in each area, and can be restricted to operateonly during certain formatsThe Control Panel prioritizes and sends reports inContact ID or Modem IIIa2 communications formats tofour route groups. Each group has a programmableprimary and backup Control Panel provides flexible communications formost central stations with reporting capabilities suchas: Individual point numbers Opening or closing reports by user and area number Remote programming attempts Diagnostic reportsIP communicationThe Control Panel uses the B426/B420 ConnetixEthernet Communication Module, DX4020 and/or theITS DX4020 G Cellular Communicator to communicatewith the Conettix D6600 and D6100i CommunicationsReceiver/Gateways.
10 Using Conettix IP communicationoffers a secure path that includes anti-replay/anti-2 | D9412GV4 Control Panelsubstitution features and provides enhanced securitywith encryption. The B420, DX4020 and ITS DX4020 Gcan all be used for remote is the first Security Control Panel to support DNS(Domain Name System) for both remote programmingand central station communication. DNS provides easeof use, eliminating the need to use static IP addressesas your reporting destination and accommodates asimple solution for central station disaster Setup is available via the installer keypad menusand the remote programming software, eliminating theneed to use complicated internet programming toolssuch as ARP and pathsThe Control Panel accommodates up to four separatedestinations for primary, alternate, and backupreceivers for automatic test resetting alarms or arming or disarming asystem.