Dunphy COMBUSTION LTD. Queensway Rochdale England OL11 2SL. data SHEET . Model: TG3 Revision Date: September 2015. Output: 200 2950 kW Revision Number: All models approved to current British and European Standards. All burners in the range are of the fan assisted, nozzle mix type and operation is fully automatic. All models have been independently tested to the European Standard BS EN676 Automatic forced draught burners for gaseous fuels.' (Natural Gas, LPG, Biogas, Hydrogen & Waste Gases ETC). CE approval numbers for the TG3 Series burners are: TG35 CE 86/AQ/269.

1 DUNPHY COMBUSTION LTD. Queensway Rochdale England OL11 2SL DATA SHEET Model: TG3 Revision Date: September 2015 Output: 200 – …

Tags:

  Sheet, Data, Data sheet

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of DATA SHEET - Dunphy

1 Dunphy COMBUSTION LTD. Queensway Rochdale England OL11 2SL. data SHEET . Model: TG3 Revision Date: September 2015. Output: 200 2950 kW Revision Number: All models approved to current British and European Standards. All burners in the range are of the fan assisted, nozzle mix type and operation is fully automatic. All models have been independently tested to the European Standard BS EN676 Automatic forced draught burners for gaseous fuels.' (Natural Gas, LPG, Biogas, Hydrogen & Waste Gases ETC). CE approval numbers for the TG3 Series burners are: TG35 CE 86/AQ/269.

2 TG37 CE 86/AQ/270. TG310 CE 86/AQ/271. 1. BURNER DIMENSIONS - HIGH / LOW & ELECTRO / PNEUMATIC. MODULATION - VGD40. GAS VALVE. All dimensions in mm unless otherwise stated. The minimum standard dimension for 'PROJ' is 230mm. However, it can be varied to suit application. Requirements should be stated when unit is ordered. Dimension E' is the average swing radius; this can vary on non-standard burners. Burner shown is right-hand hinge; left-hand hinge is an available option. Please check the issue number to ensure validity.

3 BURNER DIMENSIONS - HIGH / LOW. & ELECTRO / PNEUMATIC. MODULATION - GAS. VALVE. All dimensions in mm unless otherwise stated. 2. The minimum standard dimension for 'PROJ' is 230mm. However, it can be varied to suit application. Requirements should be stated when unit is ordered. Dimension E' is the average swing radius; this can vary on non-standard burners. Burner shown is right-hand hinge; left-hand hinge is an available option. Please check the issue number to ensure validity. 3. BURNER DIMENSIONS - ELECTRONIC MODULATION.

4 All dimensions in mm unless otherwise stated. The minimum standard dimension for 'PROJ' is 230mm. However, it can be varied to suit application. Requirements should be stated when unit is ordered. Dimension E' is the average swing radius; this can vary on non-standard burners. Burner shown is right-hand hinge; left-hand hinge is an available option. Please check the issue number to ensure validity. 4. BURNER RATING GRAPH. 5. BURNER SCHEMATICS - HIGH / LOW & PNEUMATIC MODULATING. Typical Gas Line Schematic for High / Low & Pneumatic Modulating Burners with Gas Pilot Line Typical Gas Line Schematic for High / Low & Pneumatic Modulating Burners without Gas Pilot Line BURNER SCHEMATICS - ELECTRICAL MODULATING.

5 Typical Gas Line Schematic for Electronic Modulating Burners 6. without Gas Pilot Line Typical Gas Line Schematic for Electronic Modulating Burners with Gas Pilot Line (Single Valve). Typical Gas Line Schematic for Electronic Modulating Burners with Gas Pilot Line (Twin Valve). 7. Typical Gas Line Schematic for Electronic Modulating Burners with Gas Pilot Line (Twin Valve) and Optional LPG / Propane Connection 8. STANDARD SPECIFICATION data . GAS VOLUME. Firing Rate kW FIRING MODE OPTIONS. (m3/HR) *1. BURNER Running Starting Electronic Motor kW Voltage Hz Ph TYPE Electro / Pneumatic Electronic Current Current MIN *3 MAX MIN *3 MAX High / Low Modulation with Modulation Modulation*2.

6 VSD. TG35Z 200 2000 184 380-420 50 3 9 Amp 53 Amp TG37Z 220 2200 203 380-420 50 3 11 Amp 79 Amp TG310Y 295 2950 272 380-420 50 3 16 Amp 36 Amp *1 Based on Nat. Gas kWh/m3. *2 - Fitted with a Ratiotronic 6000 system *3 Based on 10:1 turn down fitted with VSD. COMBUSTION HEAD ULTRA LOW NOx BURNERS. The Dunphy dual fuel combustion head incorporates a All Dunphy T-Series burners are fitted with low NOx two-stage fuel/air mixing system which eliminates low combustion heads as standard equipment. frequency resonance and allows maximum combustion efficiency with minimum emission levels.

7 As an optional extra all burners in this range can be fitted with an internal flue gas recirculation system to achieve This system combined with smooth ignition and extreme ultra low NOx emissions. reliability make Dunphy combustion equipment the most sensible choice for all heating and process applications. Dunphy Combustion Ltd have a policy of continuous development and reserve the right to change prices and specifications without prior notice. Dunphy Combustion Ltd. has a policy of continuous development and reserve the right to change prices and specifications without prior notice 9.