Transcription of DATA SHEET - Trojan Battery
1 RECYCLE RESPONSIBLY12V FloodedPHYSICAL SPECIFICATIONSBCI MODEL NAMEVOLTAGECELL(S)TERMINAL TYPE GDIMENSIONS C INCHES (mm)WEIGHT H LBS. (kg)GC12T-12751261, 2 LENGTHWIDTHHEIGHT F85 (39) (329) (18 1) (2 8 3)ELECTRICAL SPECIFICATIONSCRANKING PERFORMANCE CAPACITY A MINUTES CAPACITY B AMP-HOURS (Ah)ENERGY (kWh)INTERNAL RESISTANCE (m )SHORT CIRCUIT CURRENT (amps) @ 0 F (-18 C) @ 32 F (0 C)@ 25 Amps@ 56 Amps@ 75 Amps5-Hr10-Hr20-Hr100-Hr100-Hr TEMPERATURE volt per cell for every 1 C below 25 volt per cell for every 1 F below 77 volt per cell for every 1 C above 25 C volt per cell for every 1 F above 77 F OPERATIONAL DATAOPERATING TEMPERATURESELF DISCHARGE-4 F to 113 F (-20 C to +45 C).
2 At temperatures below 32 F (0 C) maintain a state of charge greater than 60%.5 15% per month depending on storage temperature SHEETMODELT-1275 with Master VentVOLTAGE12 MATERIALP olypropyleneDIMENSIONSI nches (mm)BATTERYDeep-Cycle Flooded/Wet Lead-Acid BatteryCOLORM aroonWATERINGH ydroLink Watering System MOTIVE T-127512 VOLTCHARGING INSTRUCTIONSCHARGER VOLTAGE SETTINGS (AT 77 F/25 C)SYSTEM VOLTAGE12V24V36V48 VBulk not install or charge batteries in a sealed or non-ventilated compartment. Constant under or overcharging will damage the Battery and shorten its life as with any OF CHARGE MEASURE OF OPEN-CIRCUIT VOLTAGEPERCENTAGE CHARGESPECIFIC GRAVITYCELL12 BATTERYCOMPANY WITHQUALITY SYSTEMCERTIFIED BY DNV= ISO 9001:2015 =PERCENT CAPACITY VS.
3 TEMPERATURE20%0%40%60%80%100%120%020-20- 404060801001201400-20-10-30-401020304050 60 Percent of Available CapacityTemperature (F)Temperature (C) (181) (283) (177) (329) (326) (246)Discharge Current (amps)Time (mins) Trojan T-1275 PERFORMANCE110100100010100100010000 Estimation Purposes OnlyTemperature (C)Percent of Available CapacityTemperature (F)Designed in compliance with applicable BCI, DIN, BS and IEC in compliance to BCI and IEC standards. 2019 Trojan Battery Company, LLC. All rights reserved. Trojan Battery Company is not liable for damages that may result from any information provided in or omitted from this publication, under any circumstances.
4 Trojan Battery Company reserves the right to make adjustments to this publication at any time, without notice or / + / DS 020819 Battery DIMENSIONS (shown with EHPT)TERMINAL CONFIGURATIONSG1 ELPTEMBEDDED LOW PROFILE TERMINAL2 EHPTEMBEDDED HIGH PROFILE TERMINALT erminal Height Inches (mm) (31)Torque Values in-lb (Nm) 95 105 (11 12)Bolt 5/16 Terminal Height Inches (mm) (38)Torque Values in-lb (Nm) 95 105 (11 12) Bolt 5/16 A. The number of minutes a Battery can deliver when discharged at a constant rate at 80 F (27 C) and maintain a voltage above V/cell. Capacities are based on peak The amount of amp-hours (Ah) a Battery can deliver when discharged at a constant rate at 80 F (27 C) and maintain a voltage above V/cell.
5 Capacities are based on peak performance. C. Dimensions may vary depending on type of handle or terminal. Batteries should be mounted with inches ( mm) spacing (Cold Cranking Amps) - the discharge load in amperes which a new, fully charged Battery can maintain for 30 seconds at 0 F (-18 C) at a voltage above (Cranking Amps) - the discharge load in amperes which a new, fully charged Battery can maintain for 30 seconds at 32 F (0 C) at a voltage above V/cell. This is sometimes referred to as marine cranking amps @ 32 F or @ 32 F. F. Height taken from bottom of the Battery to the highest point on the Battery .
6 Heights may vary depending on type of terminal. G. Terminal images are representative Weight may vary.