DATA SHT - Trojan Battery

T-105 data SHEETOPERATIONAL DATAO perating TemperatureSelf Discharge-4 F to 113 F (-20 C to +45 C). At temperatures below 32 F (0 C) maintain a state of charge greater than 60%.5 15% per month depending on storage temperature TEMPERATURE volt per cell for every 1 C below 25 volt per cell for every 1 F below 77 volt per cell for every 1 C above 25 C volt per cell for every 1 F above 77 F STATE OF CHARGE MEASURE OF OPEN-CIRCUIT VOLTAGEP ercentage ChargeSpecific GravityCell6 INSTRUCTIONSC harger Voltage Settings (at 77 F/25 C)System Voltage6V12V24V36V48 VBulk not install or charge batteries in a sealed or non-ventilated compartment. Constant under or overcharging will damage the Battery and shorten its life as with any in compliance with applicable BCI, DIN, BS and IEC in compliance to BCI and IEC with Bayonet CapVOLTAGE6 MATERIALP olypropyleneDIMENSIONSI nches (mm)BATTERYDeep-Cycle Flooded/Wet Lead-Acid BatteryCOLORM aroonWATERINGH ydroLink Watering SystemELECTRICAL SPECIFICATIONSC ranking Performance Capacity A Minutes Capacity B Amp-Hours (AH)Energy (kWh)Internal Resistance (m )Short Circuit Current (amps) @ 0 F (-18 C) @ 32 F (0 C)@ 25 Amps@ 75 Amps5-Hr10-Hr20-Hr100-Hr100-Hr + PHYSICAL SPECIFICATIONSBCI Group SizeTypeVoltageCell(s)Terminal Type GDimensions C Inch

DATA SHT T-105 PATIAL DATA Operating Temperature Self Discharge-4 113 (-20C 45C). A temperatur 32 (0C) stat eat 60. 5 15 or temperatur onditions.

Tags:

  Data, T 105

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of DATA SHT - Trojan Battery

1 T-105 data SHEETOPERATIONAL DATAO perating TemperatureSelf Discharge-4 F to 113 F (-20 C to +45 C). At temperatures below 32 F (0 C) maintain a state of charge greater than 60%.5 15% per month depending on storage temperature TEMPERATURE volt per cell for every 1 C below 25 volt per cell for every 1 F below 77 volt per cell for every 1 C above 25 C volt per cell for every 1 F above 77 F STATE OF CHARGE MEASURE OF OPEN-CIRCUIT VOLTAGEP ercentage ChargeSpecific GravityCell6 INSTRUCTIONSC harger Voltage Settings (at 77 F/25 C)System Voltage6V12V24V36V48 VBulk not install or charge batteries in a sealed or non-ventilated compartment. Constant under or overcharging will damage the Battery and shorten its life as with any in compliance with applicable BCI, DIN, BS and IEC in compliance to BCI and IEC with Bayonet CapVOLTAGE6 MATERIALP olypropyleneDIMENSIONSI nches (mm)BATTERYDeep-Cycle Flooded/Wet Lead-Acid BatteryCOLORM aroonWATERINGH ydroLink Watering SystemELECTRICAL SPECIFICATIONSC ranking Performance Capacity A Minutes Capacity B Amp-Hours (AH)Energy (kWh)Internal Resistance (m )Short Circuit Current (amps) @ 0 F (-18 C) @ 32 F (0 C)@ 25 Amps@ 75 Amps5-Hr10-Hr20-Hr100-Hr100-Hr + PHYSICAL SPECIFICATIONSBCI Group SizeTypeVoltageCell(s)Terminal Type GDimensions C Inches (mm)Weight Lbs.

2 (kg)LengthWidthHeight FGC2T-105631, 2, 3, (262) (181) (283)62 (28)2 EHPTE mbedded High Profile TerminalTerminal Height Inches (mm) (38)Torque Values in-lb (Nm) 95 105 (11 12)Bolt 5/16 246 259 (262) 283 177 181 WIDTHTROJAN T-105 PERFORMANCEPERCENT CAPACITY VS. TEMPERATURE20%0%40%60%80%100%120%020-20- 404060801001201400-20-10-30-401020304050 60 Temperature (C)Percent of Available CapacityTemperature (F)110100100010100100010000100000 Estimation Purposes OnlyBATTERY DIMENSIONS (shown with EHPT) / + / 2016 Trojan Battery Company, LLC. All rights reserved. Trojan Battery Company is not liable for damages that may result from any information provided in or omitted from this publication, under any circumstances. Trojan Battery Company reserves the right to make adjustments to this publication at any time, without notice or The number of minutes a Battery can deliver when discharged at a constant rate at 80 F (27 C) and maintain a voltage above V/cell.

3 Capacities are based on peak The amount of amp-hours (AH) a Battery can deliver when discharged at a constant rate at 80 F (27 C) and maintain a voltage above V/cell. Capacities are based on peak performance. C. Dimensions may vary depending on type of handle or terminal. Batteries should be mounted with inches ( mm) spacing (Cold Cranking Amps) - the discharge load in amperes which a new, fully charged Battery can maintain for 30 seconds at 0 F (-18 C) at a voltage above (Cranking Amps) - the discharge load in amperes which a new, fully charged Battery can maintain for 30 seconds at 32 F (0 C) at a voltage above V/cell. This is sometimes referred to as marine cranking amps @ 32 F or @ 32 F. F. Height taken from bottom of the Battery to the highest point on the Battery . Heights may vary depending on type of terminal. G. Terminal images are representative 2016_0701 TERMINAL CONFIGURATIONSG1 ELPTE mbedded Low Profile TerminalTerminal Height Inches (mm) (31)Torque Values in-lb (Nm) 95 105 (11 12)Bolt 5/16 3 EAPTE mbedded Automotive Post TerminalTerminal Height Inches (mm) (24)Torque Values in-lb (Nm) 50 70 ( )4 EUTE mbedded Universal TerminalTerminal Height Inches (mm) (28)Torque Values in-lb (Nm) 95 105 (11 12)Bolt 5/16 Discharge Current (amps)Time (mins)