SPECIFICATION DATA. Multispectrum IR Flame Detector X3301 . Shown with Q9033A. Aluminum Mounting Arm DESCRIPTION HIGHLIGHTS . Y E A R The X3301 is a multispectrum infrared (MIR) flame X3301 TECHNOLOGY FEATURES. 5. detector. It provides unsurpassed detection of fires Complies with FM 3260. from light to heavy hydrocarbon fuels combined EN54 certified with the highest degree of false alarm rejection. Certified SIL 2 capable The detector has Division and Zone explosion- ATEX Directive compliant WARRANTY. proof ratings and is suitable for use in indoor and Certified performance to multiple fuel types and fire sizes outdoor applications. EQP models available Long detection range to carbonaceous fires The X3301 contains three IR sensors with their associated signal HART models available processing circuitry.

The X3301 is a multispectrum infrared (MIR) flame . detector. It provides unsurpassed detection of fires from light to heavy hydrocarbon fuels combined

Tags:

  Highlights, Year, Descriptions, Description highlights year x3301, X3301

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of DESCRIPTION HIGHLIGHTS YEAR X3301 - Det-Tronics

1 SPECIFICATION DATA. Multispectrum IR Flame Detector X3301 . Shown with Q9033A. Aluminum Mounting Arm DESCRIPTION HIGHLIGHTS . Y E A R The X3301 is a multispectrum infrared (MIR) flame X3301 TECHNOLOGY FEATURES. 5. detector. It provides unsurpassed detection of fires Complies with FM 3260. from light to heavy hydrocarbon fuels combined EN54 certified with the highest degree of false alarm rejection. Certified SIL 2 capable The detector has Division and Zone explosion- ATEX Directive compliant WARRANTY. proof ratings and is suitable for use in indoor and Certified performance to multiple fuel types and fire sizes outdoor applications. EQP models available Long detection range to carbonaceous fires The X3301 contains three IR sensors with their associated signal HART models available processing circuitry.

2 The standard output configuration includes FDT/DTM capable fire alarm, fault and auxiliary relays, with an isolated 0 to 20 mA output Multiple sensitivity levels model with optional HART communication. Maximum false alarm rejection Reliable flame detection with modulated IR background The detector provides superior performance in applications that Microprocessor controlled heated optics are at the extremes, and where background infrared radiation is a Calibrated automatic optical check for each sensor eliminates normal condition: need for testing with external test lamp RFI and EMC Directive compliant Hangars Event logging with time and date stamp Offshore production platforms Offshore production ships Integral wiring compartment for ease of installation Refineries Operates under adverse weather conditions and in dirty environments Production facilities Loading racks BENEFITS.

3 Compressor stations Single detector for multiple hydrocarbon fuels Turbine enclosures Airport water curtains Low cost of coverage Automotive Painting Ability to detect smaller fires earlier LNG/LPG Solid cone of vision to 125 feet for methane Gas Separation Plants Better detection zoning capability Warehousing Best combination of flame detection and false alarm rejection Marine Low maintenance costs Reliable fault diagnostics Suitable for heavy industrial applications Explosion/flame proof (Ex d) or increased safety installations (Ex d e) in hazardous locations 10/15 90-1218. SPECIFICATIONS. Operating Voltage 24 Vdc nominal (18 Vdc minimum, 30 Vdc Shipping Weight Aluminum: 7 lbs. ( kg). maximum). Maximum ripple is 2 volts peak-to-peak.

4 (Approximate) Stainless Steel: lbs. ( kg). Power Consumption 4 watts minimum (without heater), 17 watts at 30 Vdc Field of View 90 horizontal by 75 vertical, at a minimum of 70%. with EOL resistor installed and heater on maximum. of the on-axis detection distance. Relays Contacts rated 5 amperes at 30 Vdc. Certification Fire Alarm: Form C (NO and NC contacts). normally de-energized . latching/non-latching. Class I, Div. 1, Groups B, C DEMKO 01 ATEX 130204X. Fault: Form A (NO contacts). Class II, Div 1, Groups E, F Increased Safety Model normally energized Class I, Div. 2 , Groups A, B, C II 2 G. latching/non-latching. 0539. Class II, Div 2. Groupd F II 2 D. Auxiliary: Form C (NO and NC contacts) Class III.

5 Normally energized/de-energized Ex d e IIC Gb Enclosure NEMA/Type 4X. latching/non-latching. Ex tb IIIC T130 C. For FM and CSA Zone approval information, T6 (Tamb 50 C to +60 C). Current Output 0 20 mA ( mA), with a maximum loop refer to the X3301 instruction manual T5 (Tamb 50 C to +75 C). (Optional) resistance of 500 ohms from 18 (95-8704). IP66/IP67. Vdc, 600 ohms from 20 30 Vdc. Flameproof Model Temperature Range Operating: 40 F to +167 F ( 40 C to +75 C). II 2 G. Storage: 67 F to +185 F ( 55 C to +85 C). 0539 II 2 D. Hazardous location ratings from 55 C to +125 C. IEC 61508 Ex d IIC Gb Certified SIL 2 Capable. Ex tb IIIC T130 C. Humidity Range 0 to 95% relative humidity, can withstand 100% Applies to specific models T6 (Tamb 55 C to +60 C).

6 Condensing humidity for short periods of time. Refer to the SIL 2 Certified T5 (Tamb 55 C to +75 C). X3301 Safety manual (95-8720). T4 (Tamb 55 C to +125 C). Wiring 16 AWG or mm2 shielded cable is recommended. IP66/IP67. Enclosure Material Copper-free aluminum (painted) or stainless steel RUSSIA & KAZAKHSTAN. (316/CF8M Cast). Conduit Entry Size 3/4 inch NPT or M25. VNIIFTRI. TP TC 012/2011 IECEx Certificate of Conformity Warranty 5 years. IECEx ULD TC RU C-US. ГБ Response Characteristics 2 ExdeIICT6/T5 IP66 Ex d e IIC Gb T6 (Tamb = 50 C to +60 C) Ex tb IIIC T130 C Distance Ft Average Response T5 (Tamb = 50 C to +75 C) T6 (Tamb = 50 C to +60 C) Fuel Size (m) Time (seconds)**. Ex tb IIIC T130 C Db. T5 (Tamb = 50 C to +75 C) n-Heptane 1 x 1 foot 265 ( )* 22 OR IP66/IP67.

7 N-Heptane 1 x 1 foot 250 ( ) 17. 1 ExdIICT6/T5/T4 IP66 OR . n-Heptane 1 x 1 foot 100 ( ) 3. T6 (Tamb = 55 C to +60 C) Ex d IIC Gb n-Heptane 6 in. x 6 in. 100 ( ) 7. T5 (Tamb = 55 C to +75 C) Ex tb IIIC T130 C. Very High Sensitivity Isopropanol 6 in. x 6 in. 70 ( ) 6. T4 (Tamb = 55 C to +125 C) T6 (Tamb = 55 C to +60 C). Diesel 1 x 1 foot 175 ( ) 6** T5 (Tamb = 55 C to +75 C). Ethanol 1 x 1 foot 210 (64) 11 Ex tb IIIC T130 C Db. T4 (Tamb = 55 C to +125 C). Methanol 6 in. x 6 in. 40 ( ) 3 IP66/IP67. RUSSIA. Methanol 1 x 1 foot 150 ( ) 7. Methanol 1 x 1 foot 150 ( ) 5**. Methane 32 inch plume 125 ( ) 5. Propane 32 inch plume 125 ( ) 5 VNIIPO. Jet A 1 x 1 foot 150 ( ) 4** CERTIFICATE OF CONFORMITY TO. JP-5 2 x 2 feet 235 ( ) 3**.

8 TECHNICAL REGULATIONS, UL-BR JP-8 1 x 1 foot 150 ( ) 5**. GOST R 53325-2012 Ex d e IIC T6-T5 Gb IP66/IP67. Class A 12 in. x 7 in. 150 ( ) 3** Ex tb IIIC T130 C. C-US.ПБ n-Heptane 1 x 1 foot 100 ( ) 7 T6 (Tamb = 50 C to +60 C). n-Heptane 1 x 1 foot 50 ( ) <2 T5 (Tamb = 50 C to +75 C). VdS. Medium Sensitivity Diesel 1 x 1 foot 70 ( ) 4** OR . Ethanol 1 x 1 foot 85 ( ) 7 Ex d IIC T6-T4 Gb IP66/IP67. Methanol 1 x 1 foot 70 ( ) 6 Approvals to EN54-10. See instruction Ex tb IIIC T130 C. Methane 32 inch plume 70 ( ) 6. manual for details. T6 (Tamb = 55 C to +60 C). Methane 32 inch plume 55 ( ) 4 T5 (Tamb = 55 C to +75 C). Propane 32 inch plume 75 ( ) <5 T4 (Tamb = 55 C to +125 C). JP-5 2 x 2 feet 150 ( ) 3**. Class A 12 in.

9 X 7 in. 50 ( ) 4** US Coast Guard * Outdoor test condition. Coast Guard Approval No. ** 10 second pre-burn from ignition. ** Add 2 seconds for EQP Model. DNV. Diameter Type Approval Certificate Number A-13995. NOTE: Refer to the X3301 instruction manual (95-8704) for additional sensitivity levels. DNV Certificate Number MED-B-9427. Corporate Office 6901 West 110th Street | Minneapolis, MN 55438 USA. Specifications subject to change without notice. Operator: or All trademarks are the property of their respective owners. Customer Service: or 2015 Detector Electronics Corporation. All rights reserved. | Email.