Example: biology

DESCRIPTION SPECIFICATION FEATURES - …

MetaluxSPECIFICATION FEATURESC onstruction5-5/8" deep, para-contoured housing, die formed code gauge, prime cold rolled steel. Die embossed housing has full length die formed stiffeners for added strength. Ballast/ wireway cover easily removed without tools. Die formed captive lampholder bracket fully encloses lamp-holder wiring permitting easy lampholder replacement. Heavy endplates are securely attached with interlocking tabs and screws. Four auxiliary fixture end suspension points provided. KOs for continuous row wiring. Endplates have integral Grid-Lock feature for safety and *Ballasts are CBM/ETL Class P and are positively secured by mounting bolts. Pressure lock lampholders. UL/CUL listed. Suitable for damp locations.**FinishMultistage, iron phosphate pretreatment ensures maximum bonding and rust inhibitor.

Metalu SPECIFICATION FEATURES Construction 5-5/8" deep, para-contoured housing, die formed code gauge, prime cold rolled steel. Die embossed housing has full length

Tags:

  Feature, Specification, Descriptions, Specification features, Description specification features

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of DESCRIPTION SPECIFICATION FEATURES - …

1 MetaluxSPECIFICATION FEATURESC onstruction5-5/8" deep, para-contoured housing, die formed code gauge, prime cold rolled steel. Die embossed housing has full length die formed stiffeners for added strength. Ballast/ wireway cover easily removed without tools. Die formed captive lampholder bracket fully encloses lamp-holder wiring permitting easy lampholder replacement. Heavy endplates are securely attached with interlocking tabs and screws. Four auxiliary fixture end suspension points provided. KOs for continuous row wiring. Endplates have integral Grid-Lock feature for safety and *Ballasts are CBM/ETL Class P and are positively secured by mounting bolts. Pressure lock lampholders. UL/CUL listed. Suitable for damp locations.**FinishMultistage, iron phosphate pretreatment ensures maximum bonding and rust inhibitor.

2 Lighting grade, baked white enamel Cam latch with baked enamel finish. Safety-lock T-hinges allow hinging and latching either extruded aluminum door with reinforced mitered corners and baked white enamel finish. Quadrasealed to prevent light spillage. Light stabilized 100% virgin acrylic prismatic shielding. Standard #15 pattern. Optional shielding Light ballast options areoffered for both 0-10V continuousdimming and DALI with energy-savingproducts like occupancy sensors,daylighting controls, and lightingrelay panels from Cooper Controls( ) to maximizeGC128T8, 228T8328T8132, 232, 3321' X 4' TROFFER1, 2 OR 3 T8 LAMPSS pecification Deep TrofferADF0906022016-03-01 10:50:22 The GC Series FEATURES a deep para-contoured fixture housing, high reflectivity and optimum lamp to lens spacing.

3 The series produces total uniformity of light in the luminous area and is compatible with all of today s popular ceiling systems and is available with a number of options and accessories for application SPECIFICATION luminaire is designed to offer maximum efficiency and performance for today s unique interior specifications. The GC Series is an excellent choice for commercial office spaces, schools, hospitals or retail merchandising DATA Input Watts:EB Ballast & STD Lamps128T8 (27), 228T8 (48), 328T8 (67)132 (30), 232 (55), 332 (81)Luminaire Efficacy RatingLER = FL-54 Catalog Number: GC-132 AYearly Cost of 1000 lumens,3000 hrs at .08 KWH = $ Efficacy RatingLER = FL-56 Catalog Number: GC-232 AYearly Cost of 1000 lumens,3000 hrs at .08 KWH = $ *Reference the lamp/ballast data in the Technical Section for specific lamp/ballast requirements.

4 **Consult Pre Sales Technical "[143mm]11 -3/4" [298mm]LAMPS CONTAIN MERCURY. DISPOSE ACCORDINGTO LOCAL, STATE OR FEDERAL LAWSSafe and convenient means ofdisconnecting # Type Date Project Comments Prepared by 11 -3/4"[298mm]48" [1219mm]Access Plate7/8" [22mm] (2)1-1/2" [38mm]5-1/4" [133mm]6-1/4" [159mm]3-1/2" [89mm]7/8" [22mm] (2)MOUNTING DATA5-5/8"[143mm]11 -3/4"[298mm]1 LAMP5-5/8"[143mm]11 -3/4"[298mm]X X=3-1/4" [83mm]2 LAMP5-5/8"[143mm]11 -3/4"[298mm]X X=3-1/4" [83mm]3 LAMPLAMP CONFIGURATIONSGCGCFAGCRAFlat , White Flat, Extruded Deep, Regressed,SteelWhite AluminumExtruded White AluminumDOOR FRAMESGGrid/Lay-inStandardGConcealed TGSlot GridFAluminum Flange Tr imWith SupportingSwing GatesMZModular Tr imWith SupportingSwing GatesCeilingTrimTypeTypeExposed GridGConcealed TGSlot GridGFlangeFConcealed T or Z MZMetal PanMZ(Verify compatibility/ consultPre Sales Te chnical Support.)

5 CEILING COMPATIBILITYS pecifications and dimensions subject to change without 1121 Highway 74 SouthPeachtree City, GA 30269P: of U tilizationEffective floor cavity reflectance20%rc80%70%50%30%10%0%rw70503 010705030105030105030105030100 RCR012345678910 Typical VCP PercentagesHeight AlongHeight AcrossRoom Size (Ft.) 20 x 2030 x 3030 x 6060 x 3060 x 60 Zonal Lumen SummaryZoneLumens%Lamp%Fixture0-300-400- 600-900-180 CandelaAngleAlong II45 Across 051015202530354045505560657075808590GC-2 32 AElectronic BallastF32T8/35K Lamps2800 LumensSpacing criterion:(II) 1. 2 x mountingheight, ( ) 1. 2 xmounting heightEfficiency = FL-56 Yearly Cost of 1000lumens, 3000 hrs KWH = $ 72119311 of UtilizationEffective floor cavity reflectance20%rc80%70%50%30%10%0%rw70503 010705030105030105030105030100 RCR012345678910 Typical VCP PercentagesHeight AlongHeight AcrossRoom Size (Ft.)

6 20 x 2030 x 3030 x 6060 x 3060 x 60 Zonal Lumen SummaryZoneLumens%Lamp%Fixture0-300-400- 600-900-180 CandelaAngleAlong II45 Across 051015202530354045505560657075808590GC-1 32 AElectronic BallastF32T8/35K Lamps2800 LumensSpacing criterion:(II) x mountingheight, ( ) xmounting heightEfficiency = FL-54 Yearly Cost of 1000lumens, 3000 hrsat .08 KWH = $ `766766766762766767752763769737755770714 7427676817237566376947305836496805205785 9044149147235138636127728026921519219516 012714611 T8 1 ' X 4 'ADF0906022016-03-01 10:50:22 Specifications and dimensions subject to change without 1121 Highway 74 SouthPeachtree City, GA 30269P: NUMBER: GC-132A-UNV-EB81-UNumber ofLamps(2)1, 2or 3lampsSeriesC= SPECIFICATION Deep TrofferTrim TypeG=Grid/Lay-in Standard(1)G=Concealed TG=Slot GridF=Aluminum Flange Trim(5)MZ=Modular TrimEMZ=Modular Trim(Extended Swing Arm)DoorframesStandard=Flat White Steel Door(Leave Blank)FA=Flush White ExtrudedAluminum c/w Spring LatchRA=Regressed White ExtrudedAluminum (3/8")FAN=Flush Natural AnodizedExtruded AluminumRAN=Regressed Natural AnodizedExtruded Aluminum (3/8")FAB=Flush Black ExtrudedAluminumRAB=Regressed Black ExtrudedAluminum (3/8")ShieldingA=#12 Pattern AcrylicA125=#12 Pattern Acrylic(.)

7 125" Thickness)A19/156=#19 PatternAcrylic (.156" Thickness)DA=Dropped Dish MatteWhite AcrylicIMA48=Injection MoldedAcrylic (.150" Thickness)WidthBlank=1' WidthOptionsGL=Single Element FuseGM=Double ElementFuseFlex=Flex Installed(Reference Flex orderinginformation)EL=Emergency InstalledLamps InstalledBlank=No Lamps InstalledL8835=T8 Lamp, 28W and32W, 3500K(6)L8841=T8 Lamp, 28W and32W, 4100K(6)L8835HL=T8 Lamp, 32W,3500K, 3100 LumensL8841HL=T8 Lamp, 32W,4100K, 3100 LumensOptionsPAF=Painted After Fabrication 20GA/REP=20 Gauge RivetedEndplates. For use in New York City. RLS=Rotor-Lock Socket (T8 Lamps Only)(See options & accessories )PackagingU=Unit PackPAL=Job Pack,out of cartonPALC=JobPack, in cartonWattage (Length)28T8=28W T8 (48") 32=32W T8 (48")Voltage(3)120V=120 Volt277V=277 Volt347V=347 VoltUNV=UniversalVoltage 120-277(4)NOTES: (1)An EQ Grid Clip is recommended for all 9/16" ceiling systems.

8 Four required per fixture. (2)Standard off-centerballast compartment on 3-lamp fixtures. (3)Products also available in non-US voltages and frequencies for internationalmarkets. (4)Not available when specifying emergencies, voltage must be specific. (5)Specify row configuration, type incatalog number when ordering complete fixture. (6)When utilizing 28W T8 lamps, HPT8 Ballast must be speficied. (7)For acomplete listing of Fifthlight Te chnology products and other solutions from Cooper Controls, visit (8)0-10V ballast do not include DALI feature . Please select DALI ballast for use with Fifth Light system. (9) SPECIFICATION grade 0-10 Vdimming ballast are NEMA premium and CEE listed. They are compatible with low mercury and energy saving lamps.(10) SPECIFICATION Grade 0-10V ballast not offered in 3 or 4-lamp complete product data, reference the Fluorescent SPECIFICATION binder.

9 Specifications & dimensions subject to changewithout notice. Consult your Cooper Lighting Representative for availability and ordering YorkCity RatedATW-SW4=ChicagoRatedOption Aluminum Flange Trim(5)Blank=SW (Single White)TypeColor S Single N Natural R In Row W White E End of RowA CCESSORIESEQ-CLIP-U=T-BAR SafetyEarthquake Clips(1)Ballast TypeEB8 =T8 Electronic Start. To tal Harmonic Distortion < 10%EB8 /PLUS=T8 Electronic Start. To tal Harmonic Distortion < 10%. High Ballast Factor > =T8 Electronic Program Rapid Start. To tal Harmonic Distortion < 10%High Performance T8 BallastsHB8 =T8 Electronic Instant Start. To tal Harmonic Distortion < 10%. Standard Ballast Factor .86 .88HB8 L=T8 Electronic Instant Start. To tal Harmonic Distortion < 10%.

10 Low Ballast Factor .77 .82HB8 N=T8 Electronic Instant Start. To tal Harmonic Distortion < 10%. Normal Ballast Factor H=T8 Electronic Instant Start. To tal Harmonic Distortion < 10%. High Ballast Factor 1. 15 T8 Electronic Program Rapid Start. To tal Harmonic Distortion < 10%. Standard Ballast Factor .86 .88HR8 DIM=T8 Electronic Program Rapid Start. To tal Harmonic Distortion < 10%. Step Dimming. Ballast Factor .88HR8 L=T8 Electronic Program Rapid Start. To tal Harmonic Distortion < 10%. Low Ballast Factor .71 .79HR8 H=T8 Electronic Program Rapid Start. To tal Harmonic Distortion < 10%. High Ballast Factor Dimming Ballasts(8)5 LTV8 =T8 0-10V Program Rapid Start. To tal Harmonic Distortion < 10%. Ballast Factor =T8 0-10V Spec Grade Program Rapid Start.


Related search queries