Product Description Features, Functions, Benefits

April 20083-58 For more information visit: Contactors & Starters3 Advantage Full Voltage ControlProduct Family OverviewCatalog Number ECH2211 FADP roduct DescriptionSetting the Standard in Motor ControlEaton s Cutler-Hammer Advantage Motor Starters have extended operat-ing life in a physical space require-ment one half the size of conventional motor motor overcurrent protection accurate to 2% at maximum FLC, Advantage also maintains constant coil power regardless of varying con-trol circuit conditions, eliminating coil burnout, contact chatter and welding due to low voltage of fluttering control is designed with a full complement of features that make it the most versatile motor starter in the industry.

April 2008 PG03300001E For more information visit: www.eaton.com NEMA Contactors & Starters 3-59 3 Advantage Full Voltage Control Product Family Overview Improved Protection and Motor

Tags:

  Descriptions, Eaton

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of Product Description Features, Functions, Benefits

1 April 20083-58 For more information visit: Contactors & Starters3 Advantage Full Voltage ControlProduct Family OverviewCatalog Number ECH2211 FADP roduct DescriptionSetting the Standard in Motor ControlEaton s Cutler-Hammer Advantage Motor Starters have extended operat-ing life in a physical space require-ment one half the size of conventional motor motor overcurrent protection accurate to 2% at maximum FLC, Advantage also maintains constant coil power regardless of varying con-trol circuit conditions, eliminating coil burnout, contact chatter and welding due to low voltage of fluttering control is designed with a full complement of features that make it the most versatile motor starter in the industry.

2 Multifunction overload protection options provide application flexibility while reducing inventory. Communication capability extends benefits, allowing Advantage to be interactively linked to higher order control systems for monitoring, troubleshooting and advances incorporated in the Advantage design, such as pre-start diagnostics, increased accuracy and the ability to communicate with other systems, are benefits not realized in traditional motor , Functions, BenefitsAdvantage BreakthroughsTo achieve the level of benefits envi-sioned for Advantage controls at a competitive price.

3 It was discovered early in the development process that simply improving existing design concepts would fall short of the mark. A new approach involving a higher level of technology was required. The result was the incorporation of three technical breakthroughs new current sensing monitoring, an energy-balanced contact closure system that increased life by decreasing electrical and mechanical wear and an intelligent coil controller optimizing the contact closing process based on varying control circuit condi-tions. Coordinating these break-throughs to provide enhanced motor control performance is concentrated in the SURE uses the right combination of brains and brawn in effecting a motor start.

4 The power circuit of the contactor employs heavy-duty silver alloy contacts scientifically designed for long life. The addition of a uniquely developed application-specific micro-processor chip, regulates power sup-plied to the operating coil. The regulated closing profile is tailored to existing control circuit conditions. This results in an energy balanced system which reduces armature/magnet crash and contact bounce, extending mechanical and electrical 2008PG03300001 EFor more information visit: Contactors & Starters3 Advantage Full Voltage ControlProduct Family OverviewImproved Protection and Motor UtilizationThe motor circuit monitoring and over-load protection functions of Advan-tage starters are provided by three current sensors closely monitored by the microprocessor.

5 This sensor/microprocessor combination yields a protection scheme closely paralleling that of the motor heating damage boundary expressed in terms of currentand time. Accurate to 2%, Advantage allows full utilization of motor capability without motor damage or nuisance Heaters, Small SizeAdvantage starters eliminate the need for costly heater elements and their associated installation expense. Stan-dard overload protection functions include phase loss and unbalance protection, selectable trip class, automatic/manual reset and ground current Communications Capabilities Provide Two-Way ControlAdvantage also offers low cost communication capability.

6 ON-OFF commands, status and motor data can be linked to automated control systems without the addition of costly sensors, I/O modules and transducers, in a language compatible with many computer-based software systems in use by 22 patents and proven in many years of operating experience in harsh industrial applications, Advan-tage motor starters and contactors offer the user unprecedented value at a price competitive with traditional and CertificationsNote:SeePage 18-2 for additional informa-tion on Standards and Certifications that apply to all Cutler-Hammer Enclosed Control products.

7 UL Listed cUL Listed (indicates appropriate CSA Standard investigation) ABS Type ApprovedApril 20083-60 For more information visit: Contactors & Starters3 Advantage Full Voltage ControlProduct Family OverviewCatalog Number Selection Table 3-46. Advantage Line Enclosed Control Catalog Numbering System Contact eaton for more information. Use with Sizes L 3, HMCP 600V applications 3-47. Magnet Coil Codes (System Voltage) When control power transformer modification codes (C1 C11) are used or when starter class includes CPT ( ECN07, 18), see Table 3-48for system voltage 3-48.

8 Control Power Transformer Codes (System Voltage) E C A2 221 AAF-DesignA = Advantage NEMAC lassTable01 =02 =05 =06 =07=16 =17 =18 =22 =23 =24 =33 =34 =35 =36 =37 =38 =39 =40 =41 =42 =43 =44 =45 =46 =47 =48 =49 =50 =51 =52 =53 =54 =55 =62 =63 =64 =65 =68 =69 =70 =ContactorsReversing ContactorsNon-combination Non-reversing StarterNon-combination Reversing StarterNon-combination Non-reversing Starter, with CPTC ombination Non-reversing Starter Fusible DisconnectCombination Reversing Starterwith Disconnect SwitchCombination Reversing Starter Fusible/Non-fusible Disconnect with CPTC ombination Non-reversing Starter Circuit BreakerReversing, Combination with HMCP/ECombination with HMCP/E with CPTM ultispeed 2S2W Non-combinationMultispeed 2S1W CT or VT Non-combinationMultispeed 2S1W CH Non-combinationMultispeed with Disconnect Switch, 2S2 WMultispeed with Disconnect Switch, 2S1W CT or VTMultispeed with Disconnect Switch, 2S1W CHMultispeed with HMCP/E.

9 2S2 WMultispeed with HMCP/E, 2S1W CT or VTMultispeed with HMCP/E, 2S1W CHAutotransformer, Non-combinationAutotransformer, with Disconnect SwitchAutotransformer, with HMCP/EPart-Winding, Non-combinationPart-Winding, with Disconnect SwitchPart-Winding, with HMCP/EY-D, Open Transition, Non-combinationY-D, Open Transition, with Disconnect SwitchY-D, Open Transition, with HMCP/EY-D, Closed Transition, Non-combinationY-D, Closed Transition, with Disconnect SwitchY-D, Closed Transition, with HMCP/EStd Width Pump Panel, with Disconnect SwitchStd Width Pump Panel, with HMCP/EAutotransformer Pump Panel, Disconnect SwitchAutotransformer Pump Panel, HMCP/EPart-Winding Pump Panel, DisconnectPart-Winding Pump Panel, Circuit BreakerDuplex, Non-combinationDuplex, with Disconnect SwitchDuplex.

10 With HMCP/E 3-50 3-51 3-523-53 NEMA SizeL =1 =2 =3 =Lower 1 Size 1 Size 2 Size 34 =5 =6 =Size 4 Size 5 Size 6 Modification CodesSee Page 16-40 Coil Voltage and/or Control TransformersSeeTables 3-47 and 3-48 Disconnect Fuse Clip RatingsA =B =C =D =E =F =None30A/250V R30A/600V R60A/250V R60A/600V R100A/250V RG =H =J =K =L =M =100A/600V R200A/250V R200A/600V R400A/250V R400A/600V R600A/250V RN =P =Q =R =S =T =600A/600V R800A/600V R1200A/600V R1600A/600V R2000A/600V Rby DescriptionHMCP/E or Breaker RatingsA =B =C =D =E =F =W =G =None3A7A15A30A50A70A100AH =J =K =L =M =N =P =Q =150A250A400A600A800A1000A1200A2000AR =T =5 =6 =7 =8 =9 =I =3000 Aby Description3A 7A 15A 30A 50A 100A Enclosure Type1 =2 =3 =4 =5 =6 =7 =8 =9 =Type 1 General PurposeType 3R RainproofType 4 Watertight (Painted Steel)Type 4X Watertight (304-Grade Stainless Steel)Type 4X Corrosion (Nonmetallic)