Devthane - AkzoNobel
Feb 05, 2015 · Cure at least 30 days. pH must be 10.0 or lower before painting. Acid etch or abrasive blast slick, glazed concrete or concrete with laitance. Prime using: Devran 220, Bar-Rust 231, Bar-Rust 233H, Bar-Rust 235, Tru-Glaze-WB 4030 or Pre-Prime 167 Drywall: Prime with a premium acrylic latex vapor barrier primer sealer. Previously Painted Surfaces:
Tags:
Information
Domain:
Source:
Link to this page:
Please notify us if you found a problem with this document:
Documents from same domain
Epoxy - AkzoNobel
international.brand.akzonobel.comJun 27, 2017 · A two component epoxy anti-corrosive primer pigmented with zinc phosphate. PRODUCT DESCRIPTION For use on properly prepared surfaces in both new construction situations and as an industrial maintenance primer for a wide range of anti-corrosive coatings systems for use in the offshore, petrochemical, chemical, pulp and paper and bridge industries.
Epoxy Zinc-Rich
international.brand.akzonobel.comMay 16, 2017 · A two component, metallic zinc rich epoxy primer which complies with the composition and performance requirements of SSPC Paint 20. PRODUCT DESCRIPTION As a high performance primer to give maximum protection as part of any anti-corrosive coating system for aggressive environments including those found on offshore structures, petrochemical
Rapid Recoat Epoxy - AkzoNobel
international.brand.akzonobel.comSep 22, 2015 · A two component epoxy zinc phosphate/micaceous iron oxide primer, formulated on proprietary polymer technology, which provides rapid cure and overcoating even under low temperature conditions. A high solids, low VOC product. PRODUCT DESCRIPTION As a primer for steelwork intended for use in a wide range of aggressive environments, including
Intercure 200HS - AkzoNobel
international.brand.akzonobel.comSep 22, 2015 · This product is intended for use only by professional applicators in industrial situations in accordance with the advice given on this sheet, the Material Safety Data Sheet and the container(s), and should not be used without reference to the Material Safety Data Sheet (MSDS) which International Protective Coatings has provided to its customers.
Interzone 954 - AkzoNobel
international.brand.akzonobel.comAug 21, 2017 · Interzone 954 may be applied to suitably sealed or primed concrete; contact International Protective Coatings for further advice on specification and primers. Interzone 954 can be used as a non-skid deck system by modification with addition of GMA132 (crushed flint) aggregate. Application should then be to a suitably primed surface.
Interline 984 - AkzoNobel
international.brand.akzonobel.comA two component, solvent free chemically resistant heavy duty epoxy phenolic tank lining. DESCRIPTION PRODUCT Interline 984 is intended as a lining for the protection of ferrous and non-ferrous substrates (including concrete).
Chartek 1709 - AkzoNobel
international.brand.akzonobel.comNov 20, 2017 · Airless Spray Airless Spray Thinner Cleaner Work Stoppages Clean Up Trowel Suitable Typically thinned by up to 5% solvent 15°C (59°F) 25°C (77°F) The above figures are for trowel application. Working pot life is not applicable for plural airless spray application as the product is only mixed at the spray gun, at the point of application.
ISO12944 - AkzoNobel
international.brand.akzonobel.comISO12944 is the industry standard for corrosion protection of steel structures by protective paint systems. Originally released in 1998, the standard is put together by representatives from key countries and companies ... All offshore systems must continue to go through 4,200 hours of cycling testing, which equates to 25 weeks.
Chartek 7 - AkzoNobel
international.brand.akzonobel.comMay 19, 2015 · Chartek 7 is a high performance epoxy intumescent fire protection coating system. DESCRIPTION The product is a high build, two pack material providing excellent durability and combined corrosion and fire protection. Tested and certified by Lloyd's Register (LR) and Det Norske Veritas (DNV) for structural and divisional fire protection. PRODUCT
Interzinc - AkzoNobel
international.brand.akzonobel.comNov 23, 2016 · Inorganic Zinc-Rich Silicate Prior to overcoating, Interzinc 22 must be clean, dry and free from both soluble salts and excessive zinc corrosion products. Surface temperature must always be a minimum of 5°F (3°C) above dew point. When applying Interzinc 22 in confined spaces, ensure adequate ventilation.
Related documents
Single Stage Polyurethane Enamel ESSS - Ned's Auto Body …
www.nedsautobodysupply.comWash and Etch primers must be sealed before applying topcoat for optimum performance. Total Solids By Weight (RTS) 51.0% - 69.9% Total Solids By Volume (RTS) 47.0% - 53.0% Application Guide RTS Combinations: ESSS color ESSS : ESH200 : ESX5X0 Volume Ratio: Package (as is) 6 : 1 : 1 Applicable Use Category Single-Stage Ctg Single-Stage Ctg
Tech, Single, Stage, Enamel, Polyurethane, Esss, Single stage polyurethane enamel esss