Dexter Panel SystemInstallation Guide Product Description Universal Flashing Kit Supplemental Guide for VM Pro-Zinc Traininginnovativesolutionscladdingdesig nTo enroll in a VM PRO-ZINC Training Course contact:UMICORE BUILDING PRODUCTS USA, Highwoods Blvd, Suite 104 Raleigh, NC, 27604 Phone: 919 874 7173 Fax: 919 874 Date: Please consult for current revision and drawingsPanel Dims:3'- 4" x 1'- 4 1/4" x 1 1/2" panels per box:6 panels Vertical32 7/8" Per sq ft Horizontal15 3/4" Per sq ft Radius:ConvexPer lb N/APer box38 lb Panel Dims:1'- 11 1/2" x 1'- 4 1/4" x 1 1/2" panels per box:6 panels Vertical16 1/2" Per sq ft Horizontal15 3/4" Per sq ft Radius:ConvexPer panel4 lb N/APer box25 lb HALF VM Dexter ZINC*On Center:Coverage:ConcaveWeight:N/A *Half Dexter is not to be used as a

Dexter Panel System. Installation Guide Product Description Universal Flashing Kit Supplemental Guide for VM Pro-Zinc Training. innovative cladding

Tags:

  System, Panels, Dexter, Dexter panel system

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Advertisement

Transcription of Dexter Panel System - VMZinc

1 Dexter Panel SystemInstallation Guide Product Description Universal Flashing Kit Supplemental Guide for VM Pro-Zinc Traininginnovativesolutionscladdingdesig nTo enroll in a VM PRO-ZINC Training Course contact:UMICORE BUILDING PRODUCTS USA, Highwoods Blvd, Suite 104 Raleigh, NC, 27604 Phone: 919 874 7173 Fax: 919 874 Date: Please consult for current revision and drawingsPanel Dims:3'- 4" x 1'- 4 1/4" x 1 1/2" panels per box:6 panels Vertical32 7/8" Per sq ft Horizontal15 3/4" Per sq ft Radius:ConvexPer lb N/APer box38 lb Panel Dims:1'- 11 1/2" x 1'- 4 1/4" x 1 1/2" panels per box:6 panels Vertical16 1/2" Per sq ft Horizontal15 3/4" Per sq ft Radius:ConvexPer panel4 lb N/APer box25 lb HALF VM Dexter ZINC*On Center:Coverage:ConcaveWeight:N/A *Half Dexter is not to be used as a complete System , only as starter panels for the Dexter systemVM Dexter ZINCOn Center:Coverage:ConcaveWeight:N/A Dexter Panel SystemSpecification and TolerancesWall Panel substrate and framing designs can vary greatly.

2 The Architect should consult model building code, Umicore Building Products USA s literature, or a building envelope consultant for additional information on appropriate wall designs. Consult Umicore Building Products USA, Inc. for assistance in editing the specific Notes: Verify product compatibility if products other than those listed in this guide are to be specified and installed in conjunction with the metal wall ASSURANCEVM ZINC Dexter is a factory-formed, zinc-alloy, metal wall Panel System . Zinc Alloy: percent electrolytic high-grade zinc with alloy additives of copper ( percent to percent), titanium ( percent to percent), and aluminum ( percent).

3 Thickness: .025 ( mm).Dimensional Tolerances:a. Coverage: Plus or minus 1/16 ( mm).b. Flatness at Maximum Deflection: 5/64 on 36 (2 mm on 914 mm).c. Curvature: 1/32 ( ).Installer s Qualifications: Engage an experienced installer who has completed metal wall Panel System installation similar in material, design, forming method, and extent to that indicated for this Project and with a record of successful in-service performance. Successful completion of VM PRO-ZINC Training , STORAGE, AND HANDLINGD elivery: Inspect delivered materials on arrival.

4 Report damaged materials to Umicore BP within 5 days. Deliver materials to site in Umicore BP s original, unopened containers and packaging, with labels clearly identifying product name. Deliver materials so as not to be damaged or deformed. Package metal wall panels for protection during transportation and handling. Leave protective UV-resistant film on metal wall panels ; Remove within 90 days after and Handling: Store materials in clean areas in accordance with Umicore BP s instructions. Unload, store, and erect metal wall panels in a manner to prevent bending, warping, twisting, and surface and Trim: Field-fabricated from zinc-alloy sheets.

5 Thickness: [.031 ( mm)] [.039 ( mm)]. Seal against weather. Provide finished appearance. Provide pull-out resistance and flatness. Finish: Same zinc-alloy finish as adjacent metal wall Panel System . Backside Coating Thickness: 60 Wall panels : Field install in sequential order. Engage lower edge of each Panel to upper edge of Panel below and engage right side of preceding Panel s left side. Mechanically attach panels to supports by locating concealed clips under upper and left edges of OF CONTENTSL ayout ..page 76 Points.

6 Page 8 Key Points ..page 9 Base of Wall ..page 11 Inside Corner ..page 12 Outside Corner ..page 13 Sill Flashing ..page 15 Jamb Flashing ..page 16 Head Flashing ..page 172 Weather Resistant BarrierProduct DescriptionProductDescriptionSelf - Adhering Waterproofing MembraneUncured EPDM Flashing TapeCompatible Sealants: DOW 795 SIKA 1 AZinc Plus Underlay Alternative to Type II roofing underlayment and Grade D weather resistive barrier paper specified in the 2006 Length: 164 ft (50 m), Width: 39 (1 m)Weight - 164 x 39 roll, is 18 lb (8 kg)Thickness.

7 023 ( mm)Water Vapor: 212 PermsTransmission: per ASTM E96 Method AFor a list of available products, consult Umicore Building ProductsFor a list of available products, consult Umicore Building Products12343 Weather Resistant BarrierProduct InstallationZinc Plus Underlay, Weather Resistant Barrier InstallationApply waterproofing membrane at openings, extend lap 9 beyond opening at the the uncured EPDM Flashing Tape into a one piece sill the molded EPDM corner flashing step for corners at window waterproofing membrane 9 above opening at window corner at window cap strip of Zinc Plus Underlay over waterproofing membrane at top of window, even with rough opening.

8 Cap strip to be overlapped by next run of Zinc Plus zinc plus underlay horizontallywith a 6 overlap at the material at openings 45 degrees towardthe center of the inward and attach to a roller to bond the waterproofing membrane to the Zinc Plus Underlay. Hot air may be required to help with bonding at temperatures below 65 the waterproofing membrane 9 beyond Jamb frame opening. Overlap EPDM molded corner at CodeAspectsQuantityInside CornerFlashingISC - 1 Quartz Zinc Plus Anthra Zinc Plus Pigmento Blue Plus Pigmento Green Plus Pigmento Red PlusWindow FlashingSill/JambWF - S - 1 Quartz Zinc Plus Anthra Zinc Plus Pigmento Blue Plus Pigmento Green Plus Pigmento Red PlusWindow FlashingHead 1WF - H - 1 Quartz Zinc Plus Anthra Zinc Plus Pigmento Blue Plus Pigmento Green Plus Pigmento Red PlusWindow FlashingHead 2WF - H - 2 Quartz Zinc Plus Anthra Zinc Plus Pigmento Blue Plus Pigmento Green Plus Pigmento Red

9 PlusOutside CornerFlashingOSC - 1 Quartz Zinc Plus Anthra Zinc Plus Pigmento Blue Plus Pigmento Green Plus Pigmento Red PlusDexter Panel SystemProduct description: Universal Flashing Kit5 ProductDescription CodeAspectsQuantityJ-ChannelWF - J - 1 Outside CornerOSC - 2 Stainless SteelCleatST - 1 Stainless SteelZ-StarterSSZ - 1 Flatlock ClipFLCS - 16 Dexter Panel SystemLayoutNotes_____7 Patina vs. Corrosion_____ Expansion and Contraction_____ Malleability_____ Interaction with other materials_____ Cold weather installation_____ Handling and Storage_____8 Dexter Panel SystemNotes - Six PointsDexter Panel SystemKey Points1.

10 Scaffold Check landscape for obstacles Mobile scaffolding, such as scissor lifts and bucket lifts, offer flexibility, but limit the size of the crew. Full scaffold is preferred. Repairing holes made for scaffolding may be accomplished by several means: a hinged key hole cover; plastic plugs; a complete cover piece riveted in place. Best place to attach the scaffold is the wall is inside the window Aesthetic Maintain consistent orientation of rolling direction. Do not overstress panels . Remove the plastic film from whole areas at one time continuously.