Transcription of Diagnostic Code List Diagnostic Codes Table
1 Troubleshooting279C, 279C2, 289C, 289C2 and 299C Compact Track Loaders, 287C, 277C, 277C2,287C2 and 297C Multi Terrain Loaders and 246C, 256C, 262C, 262C2 and 272C SkidSteer Loaders Machine Electronic Control SystemDiagnostic code ListDiagnostic Codes TableService Codes For The Machine ECM (MID 039)W hen troubleshooting Diagnostic Codes is necessary, see the procedure with the samediagnostic 0041 8 Volt DC SupplyFMI 03 Voltage above normalFMI 04 Voltage below normalCID 0070 Parking Brake SwitchFMI 03 Voltage above normalFMI 04 Voltage below normalCID 0091 Throttle Position SensorFMI 03 Voltage above normalFMI 04 Voltage below normalFMI 08 Abnormal SignalTable 1 Page1of11 FMI 13 Out of calibrationCID 0096 Fuel Level SensorFMI 03 Voltage above normalFMI 04 Voltage below normalCID 0110 Engine Coolant Temperature SensorFMI 03 Voltage above normalFMI 04 Voltage below normalCID 0190 Engine Speed SensorFMI 02 Data ErraticFMI 08 Abnormal SignalCID 0354 Raise Solenoid #1 FMI 03 Voltage above normalFMI 05 Current below normalFMI 06 Current above normalFMI 13 Out of calibrationCID 0355 Lower Solenoid #1 FMI 03 Voltage above normalFMI 05 Current below normalFMI 06 Current above normalFMI 13 Out of calibrationCID 0356 Dump Solenoid #1 FMI 03 Voltage above normalFMI 05 Current below normalFMI 06
2 Current above normalFMI 13 Out of calibrationCID 0357 RackbackSolenoid #1 FMI 03 Voltage above normalFMI 05 Current below normalPage2of11 FMI 06 Current above normalFMI 13 Out of calibrationCID 0358 Implement Pilot Pressure Supply SolenoidFMI 03 Voltage above normalFMI 05 Current below normalFMI 06 Current above normalCID 0367 Ride Control SwitchFMI 03 Voltage above normalFMI 04 Voltage below normalCID 0444 Starter Motor RelayFMI 03 Voltage above normalFMI 05 Current below normalFMI 06 Current above normalCID 0490 Implement Lockout SwitchFMI 03 Voltage above normalFMI 04 Voltage below normalCID 0598 Travel Speed SolenoidFMI 03 Voltage above normalFMI 05 Current below normalFMI 06 Current above normalCID 0600 Hydraulic Oil Temperature SensorFMI 03 Voltage above normalFMI 04 Voltage below normalCID 0681 Parking Brake SolenoidFMI 03 Voltage above normalFMI 05 Current below normalFMI 06 Current above normalCID 1007 JoystickMapping SwitchPage3of11 FMI 02 Incorrect SignalFMI 03 Voltage above normalFMI 04 Voltage below normalCID 1190 Armrest/Seat SwitchesFMI 04 Voltage below normalCID 1251 Alternator R-Terminal SignalFMI 04 Voltage below normalCID 1551 Engine Demand Fan SystemFMI 03 Voltage above normalFMI 05 Current below normalFMI 06 Current above normalCID 1703 Left Drive Pump Forward Control SolenoidFMI 03 Voltage above normalFMI 05 Current below normalFMI 06 Current above normalFMI 13 Out of calibrationCID 1704 Left Drive Pump Reverse Control SolenoidFMI 03 Voltage above normalFMI 05 Current below normalFMI 06 Current above normalFMI 13 Out of calibrationCID 1705 Right Drive Pump Forward Control SolenoidFMI 03 Voltage above normalFMI 05 Current below normalFMI 06 Current above normalFMI 13 Out of calibrationCID 1706 Right Drive Pump Reverse Control SolenoidFMI 03 Voltage above normalPage4of11 FMI 05 Current below normalFMI 06 Current above normalFMI 13 Out of calibrationCID 1936
3 Hydraulic System High Pressure SolenoidFMI 03 Voltage above normalFMI 05 Current below normalFMI 06 Current above normalCID 1960 Ignition Key ReaderFMI 09 Abnormal UpdateCID 2204 Auxiliary Lever #1 Position SensorFMI 03 Voltage above normalFMI 04 Voltage below normalFMI 08 Abnormal signalCID 2211 Auxiliary Valve #1 Port B SolenoidFMI 03 Voltage above normalFMI 05 Current below normalFMI 06 Current above normalCID 2212 Auxiliary Valve #1 Port A SolenoidFMI 03 Voltage above normalFMI 05 Current below normalFMI 06 Current above normalCID 2471 Cab Door Position SwitchFMI 03 Voltage above normalFMI 04 Voltage below normalCID 2474 Left JoystickForward/Reverse Position SensorFMI 03 Voltage above normalFMI 04 Voltage below normalFMI 08 Abnormal SignalPage5of11 FMI13 Out ofcalibrationCID 2475 Right Joystick Forward/Reverse Position SensorFMI03 Voltage above normalFMI04 Voltage below normalFMI08 AbnormalSignalFMI13 Out ofcalibrationCID 2476 Left Joystick Left/Right Position SensorFMI03 Voltage above normalFMI04 Voltage below normalFMI08 AbnormalSignalFMI13 Out ofcalibrationCID 2477 Right Joystick Left/Right Position SensorFMI03 Voltage above normalFMI04 Voltage below normalFMI08 AbnormalSignalFMI13 Out ofcalibrationCID 2669 Creeper Mode SwitchFMI03 Voltage above normalFMI04 Voltage below normalCID 2685 Left Drive Motor Speed Sensor #1 FMI02 Incorrect SignalFMI08 AbnormalSignalCID 2686 Left Drive Motor Speed Sensor #2 FMI02 Incorrect SignalFMI08 AbnormalSignalCID 2687 Right Drive Motor Speed Sensor #1 FMI02 Incorrect SignalFMI08 AbnormalSignalPage6of11 CID 2688 Right Drive Motor Speed Sensor #2 FMI02 Incorrect SignalFMI08 AbnormalSignalNote.
4 This Table shows the service Codes for the machine ECM service Codes for the ECMare shown on the displayareaofthe Caterpillar information ofthe service code for theECM is transferred viathe CAT DataLinkto the Caterpillar module identifier (MID)tells the service person the ECM that is sendingthe service MID for the auxiliaryhydraulicECM is Service Manualis used onlyfor service Codes withaMID Mode IdentifierThe Codes for the Failure Mode Identifier are defined bythe SAE followinglistcontains aCAT version Mode Identifier and Message Center DisplaysFMID escription of Failure00"Datavalid but above normaloperatingrange"01"Datavalid but below normaloperatingrange"02"Dataerratic,inte rmittent or incorrect"03"Voltage above normal"04"Voltage below normal"05"Current below normal"06"Current above normal"07"Mechanicalsystem not respondingproperly"08"Abnormalfrequency, pulse width,or period"09"Abnormalupdate"10"Abnormalrate ofchange"11"Failure mode not identifiable"12"Bad device or component"13"Out ofcalibration"14"Specialinstruction"Tabl e 2 Page7of11 Detailed FMIE xplanationFMI 00 "Data Valid But Above Normal Operating Range"-Everyelectronic controlsystem setsahighlimit for the expected operatingrange ofthe highlimit includes over range could be sensor that is stilloperatingbut sendingasignalabove theexpected limit willcause aFMI00to be ofthe conditions that can cause the FMI00diagnostic code to be activated are:The medium or component that is beingmonitored is above the normalrange.
5 The signalis shorted to the another voltage source. The sensor needs to be calibrated. An ECM has is unlikely. FMI 01 "Data Valid But Below Normal Operating Range"-Everyelectronic controlsystem sets alow limit for the expected operatingrange ofthe limit includes signals that are under thelower low signalcould be the oilpressure sensor is stillworkingbut sendingasignalbelow the expected limit willcause aFMI01to be ofthe conditions that can cause the FMI01diagnostic code to be activated are:The medium or component that is beingmonitored is below the normalrange. Poor connections in the circuit. The sensor has failed. An ECM has is unlikely. FMI 02 "Data erratic,intermittent or incorrect"-The signalfrom acomponent is reads the Diagnostic information can not read the signalappears to begone,unstable or datacan be correct or incorrect ,this conditionrelates to communication between is an example ofcommunication between hen the monitoringsystem is lookingfor the engine speed from the Engine ECM over the ofthe conditions that can cause the FMI02diagnostic code to be activated are:There is apoor connection in the circuit.
6 The signalis intermittent or erratic. The software has been changed. The signalis receivinginterference from another circuit. The signalis out ofthe range. An ECM has is unlikely. Page8of11 FMI 03 "Voltage AboveNormal"-The component or system voltage is higher than the often relates to ofthe conditions that could cause aFMI03diagnostic code to be activated are listed ofpower supply. A open circuit or abad connection. A short to another voltage source. The sensor or the switchhas failed. An ECM has is unlikely. FMI 04 "Voltage Below Normal"-The component or system voltage is lower than the code most often relates to apower that could cause aFMI04diagnostic code are listed circuit is shorted to aground source. The circuit is open or has apoor connection. The ground circuit has failed. A component has failed. An ECM has is unlikely. FMI 05 "Current Below Normal"-The current throughthe component or the system is lower thanthe most often related to adriver that could cause aFMI05diagnostic code are listed is an open circuit or apoor harness connection.
7 The component has failed or has an open internally. An ECM has is unlikely. FMI 06 "Current Above Normal"-The current throughthe component circuit is higher than is most often related to adriver circuit for Diagnostic code is similar toan FMI04diagnostic that could cause aFMI06 Diagnostic code are listed component has failed. There is ashort circuit to aground source in the machine harness. An ECM has is unlikely. Page9of11 FMI 07 "Mechanical SystemNot Responding Properly"-The controldetects asignalthat is sentto amechanicalsystem and the response is not that could cause aFMI07 Diagnostic code are listed component responds improperly. The component is mechanicallystuckin aposition. The mechanicalcomponent has failed. The engine is shut down. The machine is beingused improperly. FMI 08 "Abnormal Frequency,Pulse Width or Period"-This occurs when the signalis not in theexpected also relate to that could cause aFMI08diagnostic code are listed harness connections are intermittent or poor.
8 The signalis noisydue to nearbyinterference. There are loose mechanicaldevices. Incorrect component installed. The component has failed. An ECM has is unlikely. FMI 09 "Abnormal Update"-This relates to communications on the whenacontrolis not able to get information from another that could cause aFMI09diagnostic code are listed controlmodule is not communicatingon the datalinkcorrectly. The rate ofdatatransmission is abnormal. The datalinkcircuit has failed. There is amismatchofsoftware. An ECM has is unlikely. FMI 10 "Abnormal Rate of Change"-This relates to asignalthat changes too fast or too ofchange is outside ofthe expected that could cause aFMI10diagnostic code are listed component has failed Page10of11 Poorconnections in the circuit. The medium or component that is being monitored has failed. An ECM has failed. This is unlikely. FMI 11 "Failure Mode Not Identifiable"- The control identifies more than one FMI as beingresponsible for a single that could cause a FMI 11 Diagnostic code are listed is a mechanical failure.
9 There is damage to multiple circuits. An ECM has failed. This is unlikely. FMI 12 "Bad Device or Component"- The electronic control sends a signal and the electroniccontrol expects a response. The control receives no response or the response is that could cause a FMI 12 Diagnostic code are listed component has failed. There is a failure on the data link. There are one or more controls with mismatched software. An ECM has failed. This is unlikely. FMI 13 "Out of Calibration"- The electrical signal is not within limits for a specific that could cause a FMI 13 Diagnostic code are listed is required. The component has failed. The data is out ofthe range. An ECM has failed. This is unlikely. FMI 14 "Parameter Failures"- This Diagnostic code is set up for special circumstances for aparticular component. The FMI 14troubleshooting procedure for the component will list the possibleconditions that can cause this