Digital Water Flow Meter with Telemetry for Groundwater ...
3. DETAILED TECHNICAL SPECIFICATIONS OF AMR / AMI WATER FLOW METERS 3.1 Specification of flow meter Flow meters shall meet the following metrological specification: Turndown ratio of 10 or above Accuracy ± 2% Technology: electromagnetic or ultrasonic 3.1.1 Size: 1. DN40 - Flow range: 0.5 lps to 5 lps 2. DN100 - Flow range: 3 to 30 lps 3.
Tags:
Information
Domain:
Source:
Link to this page:
Please notify us if you found a problem with this document:
Documents from same domain
Guidelines/Criteria for evaluation of …
cgwa-noc.gov.ini. These guidelines supersede all the earlier guidelines with effect from 16/11/2015. The guidelines for abstraction of ground water in Notified/Non-
Guidelines, Evaluation, Criteria, Guidelines criteria for evaluation of
The office of CGWA is shifted from West Block-2, …
cgwa-noc.gov.inThe office of CGWA is shifted from West Block-2, wing-3, sector 1, R K Puram to 18/11, Jamnagar House, Man Singh Road, New Delhi w.e.f 25.10.2017.
Road, House, Singh, Jamnagar, Jamnagar house, Man singh road
List of notified Areas of the States / UTs where …
cgwa-noc.gov.inState / UT District Name District / Block / Taluka / MC Area etc Assessment Unit Assessment Unit Name Area Type List of notified Areas of the States / UTs where CGWA regulate and control ground
Related documents
Quality of Water for Making Concrete: A Review of Literature
www.ijsrp.orgpotable water for concrete making. It includes reclaimed water, groundwater, treated water from sewerand water from ready mix ... Mixing water for concrete – Specification for sampling, testing and assessing the suitability of water, including water recovered from processes in the concrete industry, as mixing water for concrete.
Petroleum refining water/wastewater management
savetexaswater.orgTable 10 Contaminant specification for reuse water 42 Table 11 Refinery wastewater reuse—summary 50 List of Figures Figure 1 Refinery water balance 3 ... Potable water (drinking water and sanitary water) required by a refinery is frequently purchased from a local municipality. If available, potable water may also
Specification, Wastewater, Water, Petroleum, Refining, Potable, Potable water, Petroleum refining water wastewater
Steel Water-Storage Tanks
www.awwa.orgThe majority of all steel potable water-storage tanks constructed in the United States adhere to specifications that reference the following American Water Works Association (AWWA) steel tank standards: • ANSI/AWWA D100, Standard for Welded Carbon Steel Tanks for Water Storage. • ANSI/AWWA D102, Standard for Coating Steel Water-Storage Tanks.
American, Water, Steel, Association, Work, Storage, Tanks, Potable, Potable water, American water works association, Steel water storage tanks
C-900/C-905 - Northern Pipe
www.northernpipe.comC-900 standard specification for polyvinyl chloride water distribution pipe. The integral bell joint system meets the requirements of ASTM D-3139 and utilizes an elastomeric seal meeting the specification defined in ASTM F-477. Northern Pipe Products AWWA C-900 Pressure Pipe for potable water carries the NSF Standard 14, the
PVC Pipe—Design and Installation - American Water Works ...
www.awwa.orgChemical and taste-and-odor evaluations of PVC compounds for potable water conveyance are conducted in accordance with procedures established by NSF Interna- ... D1784, Standard Specification for Rigid Poly (Vinyl Chloride) (PVC) Compounds and Chlorinated Poly (Vinyl Chloride) (CPVC) Compounds. The specification includes a
Installation, Specification, Water, Potable, Installation and, Potable water
LAYING OF WATER SUPPLY PIPES PRIOR TO CONNECTION
www.anglianwater.co.ukpotable water. This pipe is specially developed for services laid in the ground. It is pigmented blue ... specification prior to requesting the service connection. The preferred location is a front or side ... Water’s guide for ‘Disinfection, pressure …
IS 4031-4 (1988): Methods of physical tests for hydraulic ...
www.iitk.ac.in*Specification for Vicat apparatus (first revision ). tSpe.ification fur moulds for use in fests of cement and COlWV2te. 5.2 Prepare a paste of weighed quantity Cement with a weighed quantity of potable or distilled water, taking care that the time of gauging is not less than 3 minutes, nor more
Potable water — Specification - Punto Focal
www.puntofocal.gov.arPotable water — Specification 1 Scope This East African Standard specifies requirements and methods of sampling and test for potable water (treated potable water and natural potable water). 2 Normative references The following referenced documents are indispensable for the application of this document. For dated
Specification, Water, Potable, Potable water, Potable water specification
SPECIFICATION 331001: WATER MAINS AND …
www.hillsboroughcounty.orgOctober 2021 Specification 33 1001 | 1 SPECIFICATION 331001: WATER MAINS AND APPURTENANCES 1.1 DESCRIPTION 1.1.1 The following specification covers the design, installation, inspection, testing, and acceptance of potable water systems. Construction consists of furnishing all labor, equipment, tools, appliances
Polyethylene Water Service - plastic pipe
www.plasticpipe.com.cnDisinfecting Water Mains. For potable water systems using chlorine as a disinfectant, the recommendation limits chlorine dosage to 25mg/l free chlorine with a residual of 10 mg/l at the end of a 24-hour stand. Daily amounts of chlorine should not exceed 3 ppm at tempera-tures in excess of 75° F. Additional Information . PE piping is widely ...