Example: tourism industry

Done Headers Yes MODEL Yes Nozzle Width (in) …

ARCHITECTURAL RECESSED 16 Electric Heated Air CurtainData SheetDS-252 August, Berner International Corporation 111 Progress Ave. / New Castle / PA / 16101 / USAFDARECOMMENDEDUSDACOMPLIANCE Copyright, 2015 Berner International CorporationBerner reserves the right to alter specifications without prior CONSTRUCTION 15 high x 26 deep 1 hp two speed motor(s) Factory installed Intelliswitch digital controller White aluminum exterior panel (Optional: Custom Color or Stainless) Top Mounting only High efficiency, low noise Pro-V Nozzle Filter (washable)2 Year LimitedWarrantyNOTES: 1. Operation at 50 Hz will generate approximately a 17% reduction in air performance.

™ARCHITECTURAL RECESSED 16 Electric Heated Air Curtain Data Sheet DS-252 August, 2015 www.berner.com Berner International Corporation 800.245.4455 111 Progress Ave. / New Castle / PA / 16101 / USA

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of Done Headers Yes MODEL Yes Nozzle Width (in) …

1 ARCHITECTURAL RECESSED 16 Electric Heated Air CurtainData SheetDS-252 August, Berner International Corporation 111 Progress Ave. / New Castle / PA / 16101 / USAFDARECOMMENDEDUSDACOMPLIANCE Copyright, 2015 Berner International CorporationBerner reserves the right to alter specifications without prior CONSTRUCTION 15 high x 26 deep 1 hp two speed motor(s) Factory installed Intelliswitch digital controller White aluminum exterior panel (Optional: Custom Color or Stainless) Top Mounting only High efficiency, low noise Pro-V Nozzle Filter (washable)2 Year LimitedWarrantyNOTES: 1. Operation at 50 Hz will generate approximately a 17% reduction in air performance.

2 2. Performance data based on AMCA licensed data from unheated does not recommend ARC16-1060E, ARC16-2108E and ARC16-2120E, exists only as an equivalent to competitors models. See sheet EP-252 for amp draws/total load requirements and alternate kW. Patented venturi open helical element with point suspension Thermal overload protection Galvanized steel frame Alternate kW: see sheet EP-252 MODELN ozzle Width (in)Max Vel. at Nozzle (fpm)Avg. Outlet Vel. (fpm)Air Volume (cfm)Outlet Vel. UniformityPower Rating (kW) Motor(s) @ hpMax Electric Capacity (kW)Heater Output (MBH) Air Temp.

3 Rise ( F)Net Wt. (lbs) ,2502,3682,07290% @ 108 DoneCk d ,5942,2082,25488% @ 115 HeadersYesYe ,6272,0152,35177% @ 121 MODELYesYe ,4011,5022,41073% @ 141 Nozzle Width (in)YesYe ,4402,4463,92492% @ 185 Max Vel. at Nozzle (fpm)YesYe ,2502,3684,14490% @ 195 Avg. Out. Vel. (fpm)YesYe ,5942,2084,50888% @ 208 Air Volume (cfm)YesYe ,6271,9544,70277% @ 219 Outlet Vel. ,2502,4925,99690% @ 265 Power Rating (kW)YesYe ,4011,8144,76173% @ 237 Motor(s) @ hpYesYe ,2502,3686,21690% @ 293*Max. Electric Capacity (kW)YesYe ,4011,6954,82073% @ 255 Heater Output (MBH)YesYe ,5942,3146,58088% @ 305 Air Temp.

4 Rise ( F)YesYe ,6272,1386,85977% @ 317 Net Wt. (lbs)YesYe ,6272,0157,05377% @ 328 Text & ColumnsYesYe ,2502,3688,28890% @ 390 For Door Heights To 16 (environmental separation) Sound level measured 10 (3m) from the unit in free field:1 motor: Low/High Speed: 63/65 dBA2 motors: Low/High Speed: 66/68 dBA 3 motors: Low/High Speed: 68/70 dBA 4 motors: Low/High Speed: 69/71 dBAMODEL NUMBER CONFIGURATIONE=Electric HeatedARC16-1 036 E B-R-SSARC16 Series036 - 144 Opening Width # of Motors1, 2, 3, 4 HeatVoltageSS=Stainless SteelCC=Custom ColorOpt. Cabinet Finish *B=208/1/60 *J=240/1/60*V=220/1/50 X=208/3/60 Y=240/3/60 Z=480/3/60 Q=600/3/60 O=380/3/50 *Max 16kWSee sheet EP-252for available lengths and voltagesRemoteDisplayOpt.

5 DisplayIntelliswitch Berner International Corporation 111 Progress Ave. / New Castle / PA / 16101 / USA Copyright, 2015 Berner International CorporationBerner reserves the right to alter specifications without prior 1 of 2 ARCHITECTURAL RECESSED 16 Electric Heated Air CurtainElectrical Performance SheetEP-252 June, 2015 MODELkWoptionTempRise F#CKTSAMPS PER CIRCUIT(including motor)BREAKER RATINGPER CIRCUIT#CKTSAMPS PER CIRCUIT(including motor)BREAKER RATINGPER CIRCUIT#CKTSAMPS PER CIRCUIT(including motor)BREAKER RATINGPER CIRCUIT#CKTSAMPS PER CIRCUIT(including motor)BREAKER RATING PER AMP DRAW = each240/1/60 (voltage code J) or208/1/60 (voltage code B)220/1/50 (voltage code V)

6 208/3/60 (voltage code X)240/3/60 (voltage code Y)MOTOR AMP DRAW = eachMOTOR AMP DRAW = eachMOTOR AMP DRAW = eachARC16-1036 EARC16-1042 EARC16-1048 EARC16-1060 EARC16-2060 EARC16-2072 EARC16-2084 EARC16-2096 EARC16-2108 EARC16-2120 EARC16-3096 EARC16-3108 EARC16-3120 EARC16-3132 EARC16-3144 EARC16-4144 EPage 2 of Berner International Corporation 111 Progress Ave. / New Castle / PA / 16101 / USA Copyright, 2015 Berner International CorporationBerner reserves the right to alter specifications without prior notice. ARCHITECTURAL RECESSED 16 Electric Heated Air CurtainElectrical Performance SheetEP-252 June, 2015 MODELkWoptionTempRise F#CKTSAMPS PER CIRCUIT(including motor)BREAKER RATING PER CIRCUIT#CKTSAMPS PER CIRCUIT(including motor)BREAKER RATING PER CIRCUIT#CKTSAMPS PER CIRCUIT(including motor)BREAKER RATING PER (voltage code Z)600/3/60 (voltage code Q)MOTOR AMP DRAW = eachMOTOR AMP DRAW = each380/3/50 (voltage code O)

7 MOTOR AMP DRAW = eachARC16-4144 EARC16-1036 EARC16-1042 EARC16-1048 EARC16-1060 EARC16-2060 EARC16-2072 EARC16-2084 EARC16-2096 EARC16-2108 EARC16-2120 EARC16-3096 EARC16-3108 EARC16-3120 EARC16-3132 EARC16-3144E