Example: tourism industry

DuPont Pyralux AP

DuPont Pyralux AP. flexible circuit materials Technical Data Sheet Description Table 1. DuPont Pyralux AP flexible circuit material is a DuPont Pyralux AP. double-sided, copper-clad laminate and an all- Product Offerings*. polyimide composite of polyimide film bonded to Dielectric Copper copper foil. This material system is ideal for multilayer Thickness Thickness Product Code flex and rigid flex applications which require advanced mil m (oz/ft2). material performance, temperature resistance, and high reliability. AP 7163E** 9 (.25). AP 7164E** 12 (.33). Offered in a full range of dielectric thicknesses, AP 8515R 18 ( ). DuPont Pyralux AP flexible circuit materials provide designers, fabricators, and assemblers a versatile op- AP 9111R 35 ( ).

DuPont™ Pyralux® AP flexible circuit materials Technical Data Sheet Description DuPont™ Pyralux® AP flexible circuit material is a double-sided, copper-clad laminate and an all- polyimide composite of polyimide film bonded to

Tags:

  Dupont, Flexible

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of DuPont Pyralux AP

1 DuPont Pyralux AP. flexible circuit materials Technical Data Sheet Description Table 1. DuPont Pyralux AP flexible circuit material is a DuPont Pyralux AP. double-sided, copper-clad laminate and an all- Product Offerings*. polyimide composite of polyimide film bonded to Dielectric Copper copper foil. This material system is ideal for multilayer Thickness Thickness Product Code flex and rigid flex applications which require advanced mil m (oz/ft2). material performance, temperature resistance, and high reliability. AP 7163E** 9 (.25). AP 7164E** 12 (.33). Offered in a full range of dielectric thicknesses, AP 8515R 18 ( ). DuPont Pyralux AP flexible circuit materials provide designers, fabricators, and assemblers a versatile op- AP 9111R 35 ( ).

2 Tion for a wide variety of flexible circuit constructions. AP 7156E** 9 (.25). AP 7125E** 12 (.33). Low CTE for rigid flex multilayers Excellent thermal resistance AP 8515E** 18 ( ). Thin Cu-clads with superior handling AP 8525E** 18 ( ). Unique thick-core product for controlled imped- AP 8525R 18 ( ). ance AP 9121R 35 ( ). Excellent dielectric thickness tolerance/electrical AP 9222R 70 ( ). performance High Cu-polyimide adhesion strength AP 8535R 18 ( ). Full compatibility with PWB industry processes, AP 9131R 35 ( ). IPC 4204/11 certified AP 9232R 70 ( ). UL 94V-0, UL 796, 180 C (356 F) max. operating AP 8545R 18 ( ). temperature AP 9141R 35 ( ). AP 9242R 70 ( ).

3 AP 8555R 18 ( ). AP 9151R 35 ( ). AP 9252R 70 ( ). AP 8565R 18 ( ). AP 9161R 35 ( ). AP 9262R 70 ( ). Add R to the end of the code to specify rolled-annealed copper foil ( , AP 9121R). Add E to the end of the code to specify electro- deposited copper foil ( , AP 9121E). If rolled-annealed double-treat copper foil is specified, add the letter D to the end of the product code ( , AP 9121D). *Additional balanced/unbalanced copper constructions and dielectrics (>6 mil) are available through your DuPont Representative. **Available in ED copper only Table 2. Typical DuPont Pyralux AP Material Properties IPC TM-650 AP-9111 AP-9121 AP-9131 9161. Laminate Property (* or other) 1 mil dielectric 2 mil dielectric 3 6 mil dielectric Adhesion to Cu (Peel Strength) Method As fabricated, N/mm (lb/in) (9) > (10) > (10).

4 After solder, N/mm (lb/in) (9) > (10) > (10). Solder Float at 288 C (550 F) Method Pass Pass Pass Dimensional Stability Method Method B, % to to to Method C, % to to to Dielectric Thickness Tolerance, % Method +10 +10 +10. UL Flammability Rating *UL-94 V-0 V-0 V-0. Dielectric Constant*, 1 MHz Method Dissipation Factor*, 1 MHz Method Dielectric Strength, kV/mil Method 6 7 6 7 6 7. Volume Resistivity, ohm-cm Method E16 E17 E17. Surface Resistance, ohms Method >E16 >E16 >E16. Moisture and Insulation Res., ohms Method E11 E11 E11. Moisture Absorption, % Method Tensile Strength, MPa (kpsi) Method >345 (>50) >345 (>50) >345 (>50). Elongation, % Method >50 >50 >50.

5 Initiation Tear Strength, g Method 700 1000 900 1200 900 1200. Propagation Tear Strength, g Method >10 >20 >20. Chemical Resistance, min. % Method Pass, >95% Pass, >95% Pass, >95%. Solderability *IPC-S-804, M. 1 Pass Pass Pass Flexural Endurance, min. cycles Method 6000 6000 6000. Glass Transition (Tg), C --- 220 220 220. Modulus, kpsi --- 700 700 700. In-Plane CTE (ppm/C) T<Tg --- 25 25 25. In-Plane CTE (ppm/C) T<Tg --- 40 (est.) 40 (est.) 40 (est.). *See Page 6, Figures 6 and 7 for dielectric constant and loss tangent performance at higher frequencies Product Highlights and Applications 1 mil AP-7163E* 2 mil AP-7156E*. DuPont Pyralux AP AP-7164E DuPont Pyralux AP AP-7125E.

6 flexible circuit materials AP-8515 flexible circuit materials AP-8525. AP-9111 AP-9121. A Thin High-Performance Sheet Clad Laminate The Flagship All-Polyimide flexible Composite for High Density Flex Circuits 2 mil DuPont Pyralux AP flexible circuit materials adhesiveless laminate is ideal for double sided, multilayer flex as well as rigid flex applications requiring advanced material performance and high reliability. All-polyimide constructions enable designers, fabricators, and assemblers to achieve higher density, premium performance flexible circuitry. 2 mil DuPont Pyralux AP supports ad- vanced circuit designs through its core polyimide chemistry strengths: Low thermal expansion coefficient for rigid flex fabrication and assembly Excellent thermal resistance to high-temperature assembly Good dimensional stability consistency Superior mechanical and electrical properties Double sided 1 mil DuPont Pyralux AP flexible and compatibility with severe environment circuit materials were developed for high-reliability applications flexible circuit applications requiring thin dielectric profiles and superior performance offered by its all- 2 mil DuPont Pyralux AP flexible circuit materials polyimide construction.

7 The high material modulus are fully compatible with existing PCB processes and provides excellent handling characteristics in a thin material handling systems. A double-treat RA copper adhesiveless laminate. All 1 mil DuPont Pyralux offering provides the fabricator a unique construction AP flexible circuit materials constructions are UL to minimize surface preparation costs and increase rated and fully certified to IPC-4204/11. 1 mil overall final yields. DuPont Pyralux AP flexible circuit materials Typical 2 mil DuPont Pyralux AP flexible circuit ma- features: terials Properties: mil adhesiveless core dielectric with excel- lent thickness uniformity for consistent electri- cal performance Table 3.

8 High adhesion strengths and uniform perfor- 288 C (550 F) Solder Float Performance mance profiles Pyralux AP Conditions Results Excellent long-term thermal exposure perfor- Solder Float mance (Figure 1) and harsh environment Resistance Thermal Stress, 10 layer circuit similar Pass Solder Shock to 50884C. Figure 1. 150 C (302 F) Continuous 100 mil centers, No blisters, Temperature 288 C (550 F) delamination, 10-second dwell time solder wicking Test Method: IPC-TM-650, *See Table 1. Additional copper/metal constructions available on request. Figure 2. Moisture and Insulation Resistance Chemical Resistance Table 4. Chemical Absorption Weight Change (%) Weight Change (%).

9 24 hr Immersion 24 hr Immersion Pyralux AP Pyralux LF Pyralux AP Pyralux LF. (polyimide) (acrylic) (polyimide) (acrylic). 2 N Sulfuric Acid KOH ( , 55 C) ( ) ( ). Isopropanol .79 Permanganate ( ). Methyl Ethyl Ketone (MEK) .42 Para-formaldehyde Cupric Chloride Etchant .65 EDTA (E-less plating) Test Method: IPC-TM-650, Notes: All chemical immersions are 24 hours followed by roll drying. Values in parenthese indicate weight loss after immersion. Other values represent weight gain Table 5. Automotive Fluids Resistance % Retention Weight% % Retention Weight%. of Original Change After of Original Change After Immersion Fluid Peel Strength Immersion Immersion Fluid Peel Strength Immersion Anti-Freeze 95 Transmission Fluid 100 Detergent Solution 96 Unleaded Gasoline 99 Motor Oil (10W30) 102 Diesel Fuel 100 Brake Fluid 102 Sour Gasoline 100 Test Method: IPC-TM-650, (peel strength Notes: Sample data based on 2-minute immersions, 100 cycles.)

10 Test construction: AP-9121. 2 mil DuPont Pyralux AP flexible circuit materials Environmental Performance Figure 3. Thermal Aging, 150 C (302. Figure 4. Thermal Cycling Figure 5. Temperature/Humidity Exposure Figure 6. Dielectric Constant vs. Frequency Figure 7. Loss Tangent vs. Frequency 3 mil AP-9131* Figure 8 illustrates the fabrication benefits of thick DuPont Pyralux AP.. AP-9141 DuPont Pyralux AP flexible circuit materials core flexible circuit materials AP-9151 (vs. standard 2 mil) in a nominal 50 y impedance AP-9161 microstrip circuit. Copper traces with 2x greater line/. space resolution can be used to achieve identical A New Alternative for High Frequency and electrical performance while greatly reducing fabrica- Controlled Impedance Design tion yield loss from fine line imaging.)


Related search queries