E3EB-xxx-H Series FEATURES and BENEFITS

TECHNICALSPECIFICATIONS Choice of Air Conditioning Options: From 2 to 5 tons A/C ready. Easy Open Door: Secures the door firmly for transit, yet allows easy removal for access. Effective Air Filter: Universal disposable filter is read-ily available and simple to replace. Nichrome Heating Elements: Provide long lasting, efficient heating. Appliance Quality Door: Protects against rust and other corrosion. Baked enamel finish allows for easy cleaning. Fully Insulated Cabinet: Insures minimized heat loss and quiet operation. Safety and Dependability: Auto reset controls protect unit's electrical circuitry and helps ensure trouble free performance. Built in circuit breakers for extra safety.

Electric Furnaces The E3 Series furnace is designed for all sizes of manufactured and modular homes These units incor. porate reliability and low maintenance. Units may be installed free standing in a utility room or enclosed in an alcove or closet. E3 Series furnaces are A/C ready, with multiple

Tags:

  Feature, Series, Electric, Benefits, Furnace, H series features and benefits, Series furnace

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of E3EB-xxx-H Series FEATURES and BENEFITS

1 TECHNICALSPECIFICATIONS Choice of Air Conditioning Options: From 2 to 5 tons A/C ready. Easy Open Door: Secures the door firmly for transit, yet allows easy removal for access. Effective Air Filter: Universal disposable filter is read-ily available and simple to replace. Nichrome Heating Elements: Provide long lasting, efficient heating. Appliance Quality Door: Protects against rust and other corrosion. Baked enamel finish allows for easy cleaning. Fully Insulated Cabinet: Insures minimized heat loss and quiet operation. Safety and Dependability: Auto reset controls protect unit's electrical circuitry and helps ensure trouble free performance. Built in circuit breakers for extra safety.

2 Adaptable: Unit can be adapted to provide depend-able heating in either downflow or upflow mode. Versatile: Works with self-contained or split system air conditioners or heat SeriesDownflow, Upflow electric FurnacesThe E3 Series furnace is designed for all sizes of manufactured and modular homes. These units incorporate reliability and low maintenance. Units may be installed free standing in a utility room or enclosed in an alcove or closet. E3 Series furnaces are A/C ready, with multiple blower combinations for cooling and BENEFITS2320" (508 mm)CabinetInsulationUpflow Coil Cabinet23 3/4" (603 mm)29"(737 mm)Optional AccessoriesMODEL IDENTIFICATIONI ndoor Coil(optional)Coil Air Filters(used with indoor coil) furnace Air Filter(NOT used with coil air filters)Control PanelCover (left)Data LabelCircuit BreakersControl Panel Cover (right)

3 BlowerFurnace Parts IdentificationE 3 EB - 010 HProduct TypeE - electric FurnaceGeneration3 - Third SeriesProduct IdentifierEB - A/C Blower Equipped RelayElectrical CodeH - 240-1-60 Primary Capacity010 - 10 kw 012 - 12 kw015 - 15 kw 017 - 17 kw020 - 20 kw 023 - 23 Stand4 electric furnace ModelsE3EB010H012H015H017H020H023H023H 5-TonRated Heating Output, Btuh (see note 1)35,00041,00053,00057,00070,00075,00075 ,000 Watts (Total kw, Heating Elements and Blower) Voltage240 Volts/60Hz/1-PhaseHeating Elements, No.(Total kw)2 ( )2 ( )3 ( )3 ( )4 ( )4 ( )4 ( )Blower Wheel " Dia, 8" Wide11 Dia., 8 WMotor Speed, Rating, Amps4 Speed, 1/3 HP, Spd, 3/4HP AmpsTest ESP, in.

4 Cooling Available with factory installed - Ton (see note 4) - TonOptional Heat Pump Available with factory installed - Ton Air Filter (Standard)16 x 20 x 1 (nominal) furnace DimensionsWidth-20 (508mm), Height-29 (737mm) (see note 2), Depth-24 1/2 (623mm)1. Heating output rated at listed voltage. For outputs at voltages other than 240V, multiply Btuh rating by the following factors: x (230V), x (220V), x (208V)2. Height is 56" with return air grille installed, 58" with coil cabinet and 72" with coil cabinet and upflow The factory installed blower for the EB models can be replaced with a multi-speed blower allowing the units to accept up to 5 tons of air conditioning or heat SPECIFICATIONS5 Blower PerformanceAnticipator Settings Service Clearance For upflow application using upflow stand, 1" minimum per side.

5 * Can be H or BCAUTION: When sizing the wire, you must follow the guidelines of the latest revision of the NEC. * Minimum overcurrent protection per NEC 424-3b not to be less than 125% of total amps for fixed resistance Number E3E(*)Supply CircuitTotal AmperesMaximum Over-current RatingMinimum Circuit AmpacityLow Voltage Thermostat Wire system maximum wire lengths: 24 55 22 90 20 140 18 225 A B A B A or more Wire systems maximum wire lengths: 24 25 22 45 20 70 18 Ga= 110 Dual B A B A B furnace for E2E(*)-015 HBE2E(* ) furnace for E2E(*)-015 HBDual A B E3EH Blower with Filter, @ ESPPin #1 Low840#2 High11604-Ton Blower with Coil andCoil Filters, @ ESPPin #1 Low880# # #4 High14605-Ton Blower, with Coil and Coil Filters, @ ESPPin #1 Low990# # #4 High1790 ELECTRICAL SPECIFICATIONSF urnace ModelThermostat Anticipator Setting010, , 017, 020, MODELSCLOSETALCOVEF ront 6 18 Back0 0 Sides 0 0 To p0 0 Top and Sides of Duct0 0 Bottom of Duct0 0 Clearances6 AIRFLOW DATAE3EB (010, 012, 015, 017, 020, 023)

6 HCoilHighMed HighMed LowLow4-tonNo tonNo Coil3-tonNo (ESP)in 023H-5 TON and 5 ton accessory blowerCoilHighMed HighMed LowLow5-tonNo Coil5-tonNo Coil5-tonNo Coil5-tonNo CoilStatic(ESP)in NumberBlower, 2-4 Ton902993 Blower, 5 Ton902985 Heating Thermostat Intertherm (12 Pac)903188 (903182)Heating Thermostat Miller (12 Pac)903189 (903183)Thermostat Sub-Base914146 Heating/Cooling Thermostat CM65 Intertherm/Miller (12 Pac)903992 (903993)Heating/Cooling Thermostat GE Intertherm (12 Pac)903192 (903186)Heating/Cooling Thermostat GE Miller (12 Pac)903193 (903187)Automatic Damper for AC or HP Package Unit901083 VEE Box Adapters (10 ) - 5 / carton901985 Duct Connector 10 Dia. x 6 Long - 6 / carton902926 VEE Box Adapters (12 ) - 5 / carton902149 Single Wide Fitting Kit (12 )911468 ADouble Wide Fitting Kit (12 )911469 ASingle Wide Fitting Kit (14 )914957 Double Wide Fitting Kit (14 )914956Y-Fitting (12 )911470Y-Fitting (14 )917195 Fan Delay Kit (TDR)911758 Top Grille/Frame902989 Top Grille/Frame (4 pack)903000 Wall Mount Top Grille (10 pack)902988 Coil Cabinet Upflow902976 Coil Cabinet Downflow903891 Upflow NORDYNE.

7 All Rights (Replaces 936B-1110)GENERAL TERMS OF LIMITED WARRANTY8000 Phoenix Parkway | O'Fallon, MO 63368-3827 Specifications and illustrations subject to change without notice and without incurring obligations. Printed in (10/2011)For complete details of the Limited Warranty, including applicable terms and conditions, see your local installer or contact the NORDYNE warranty department for a KITSVent KitsPart NumberSoffit Air Inlet (for VentilAire III only)917201 AVentilAire III - Sloped 3/12914098 VentilAire IV - Sloped 3/12914229 Plenum ConnectorsPart / / / / / / / / carton902681A