Transcription of ecoFITpure - Vaillant UK
1 EnInstallation and maintenance instructionsecoFIT pure612 - 630 0020230533_07 - and maintenance instructions ecoFIT pure 0020230533_07 Installation and safety information .. (directives, laws, standards).. of relevant standards for Great Britain 52 Guarantee and Customer 63 Technical 74 Notes on the documentation .. 115 Product Water Association .. on the identification elements: System the scope of Ventilation .. the mounting the the front Removing/installing the side section .. for the water .. compliance with the local gas group.
2 And water connections .. the drain pipework for theexpansion relief valve .. the condensate discharge pipe .. installation .. concept .. level up the installer Monitor (status codes) .. check out the initial and treating the heating water/fillingand supplementary water .. the condensate trap .. on the product .. danger arising from insufficient the heating installation for the firsttime ("cold") .. and purging the heating installation .. the domestic hot water the gas setting .. Thoroughly flushing the heating installation("hot").. Checking leak-tightness.
3 3010 Adapting the unit to the Setting the burner anti-cycling time .. Setting the pump Setting the bypass Setting the domestic hot water 3211 Handing over to the end 3212 Inspection and maintenance .. Complete Service Interval Record section .. Using original Observing inspection and maintenanceintervals .. Checking the CO content .. Setting the CO content .. Removing the gas-air mixture Cleaning the heat Checking the burner .. Checking the ignition electrode .. Cleaning the condensate Installing the gas-air mixture Draining the product.
4 Checking the pre-charge pressure of theexpansion vessel .. Completing inspection and maintenance work .. 3513 Troubleshooting .. Eliminating Calling up and clearing the fault memory .. Resetting parameters to factory Preparing the repair work .. Replacing defective Checking the product for leak-tightness .. 3814 Decommissioning the 3815 Recycling and and maintenance 40 BOverview of diagnostics 41 CStatus codes Overview .. 45 DOverview of fault codes .. 46 EWiring diagram: system 48 FWiring diagram: system boiler (30 kW) .. 49 GCommissioning 50 HCommissioning Flow Chart.
5 EcoFIT pure Installation and maintenance instructions31 Intended useThe product is intended as a heat generatorfor closed heating installations and for do-mestic hot water use of any kind is use also includes the following: use of the product only in mobile homesthat are made, transported once and per-manently situated in Great Britain and Ire-land. After the transportation of the mo-bile home to its destination the completeproduct must be checked for leak-tightnessagain validity of the product only for Great Britainand Ireland and for the gas types in GreatBritain and Ireland as listed on the dataplate Installing and operating the product onlyin conjunction with accessories for theair/flue pipe which are listed in the otherapplicable documents and comply with thetype of unit Using the product while observing the ac-companying operating.
6 Installation andmaintenance instructions for the productalong with all other components of the in-stallation Installing and setting up the product whileobserving the product and system ap-proval Observing all inspection and maintenanceconditions listed in the instructions Installing while observing the IP codeThe following is classed as improper use: Using the product in vehicles, such as mo-bile homes or caravans. Units that are notclassed as vehicles are those that are in-stalled in a fixed and permanent location(known as "fixed installation"). Any direct use in industrial or commercialprocesses Any use other than those described inthese instructions and any use that goesbeyond what is described QualificationThe person carrying out the work describedhere must have completed professional train-ing.
7 The competent person must demon-strably have all of the knowledge, skills andcapabilities that are required in order to carryout the work mentioned following work must only be carried outby competent persons who are sufficientlyqualified to do so: Set-up Dismantling Installation Start-up Inspection and maintenance Repair Decommissioning Proceed in accordance with current tech-nology. Use the correct above-mentioned work must always onlybe carried out by persons with sufficient product can be used by children overeight years old and also by persons with lim-ited physical, sensory or mental capabilitiesor insufficient experience and/or knowledge ifthey are supervised or have been providedwith instructions on how to safely use theproduct, and they understand the risks res-ulting from using the product.
8 Children mustnot play with the product. Cleaning and usermaintenance work must not be carried out bychildren unless they are General safety informationThe following sections convey importantsafety information. It is essential to read andobserve this information in order to preventrisk of death, risk of injury, material damageor environmental GasIf you smell gas: Avoid rooms that smell of gas. If possible, open doors and windows fullyand ensure adequate ventilation. Do not use naked flames ( lighters,matches). Do not and maintenance instructions ecoFIT pure 0020230533_07 Do not use any electrical switches, mainsplugs, doorbells, telephones or other com-munication systems in the building.
9 Close the emergency control valve or themain isolator. If possible, close the gas stopcock on theproduct. Warn other occupants in the building byyelling or banging on doors or walls. Leave the building immediately and ensurethat others do not enter the building. Notify the gas supply company orthe Emergency Service Provider+44 (0) 800 111999 by telephone once youare outside of the Flue gasFlue gases may cause poisoning, while hotflue gases may also cause burns. Flue gasesmust therefore never be allowed to to do if you smell flue gas in the prop-erty: Open all accessible doors and windowsfully to provide ventilation.
10 Switch off the product. Check the flue gas routes in the productand the flue gas prevent flue gas exit: Only operate the product if the air/flue pipehas been completely installed. With the exception of short periods fortesting purposes, only operate the productwhen the front casing is installed andclosed. If you operate the product with an emptycondensate trap / siphon, then flue gasmay escape into the room air. In order to operate the product, ensure thatthe condensate trap / siphon is always ensure that the seals are not damaged: Instead of grease, use only water or com-mercially available soft soap to aid ElectricityThe power supply terminals L and N remainlive even if the unit main switch is prevent electric shocks, proceed as fol-lows before working on the product: Disconnect the product from the powersupply by switching off all power suppliesat all poles (electrical partition with a con-tact gap of at least 3 mm, fuse or cir-cuit breaker) or remove the mains plug (ifpresent).