Operating instructions For the operator Operating instructions ecoFIT pure 612 - 630. GB, IE. Publisher/manufacturer Vaillant GmbH. Berghauser Str. 40 D-42859 Remscheid Tel. +49 21 91 18 0 Fax +49 21 91 18 2810. Contents Contents 5 Troubleshooting .. 13. Detecting and rectifying 13. 1 Safety .. 3 Calling up (Live monitor) status Action-related warnings .. 3 codes .. 13. Intended use .. 3 6 Care and maintenance .. 14. General safety 4 Maintenance .. 14. 2 Notes on the documentation .. 7 Caring for the product .. 14. Observing other applicable Reading maintenance documents .. 7 messages .. 14. Storing 7 Checking the condensate drain Applicability of the 7 pipework and 14. 3 Product 7 7 14. Front view .. 7 Temporarily decommissioning Control 7 the 14. Displayed 8 Permanently decommissioning the 14. Information on the identification plate .. 8 8 Recycling and 14. Serial number .. 9 9 Guarantee and customer service .. 15. CE label .. 9.

Vaillant is a licensed member of the Benchmark Scheme. Benchmark places responsibilities on both manufacturers and installers. The purpose is to ensure that customers are provided with the correct equipment for their needs, that it is installed, commissioned and serviced in accordance with the manufacturer’s instructions by a

Tags:

  Vaillant, Vaillant uk

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Advertisement

Transcription of Operatinginstructions - Vaillant UK

1 Operating instructions For the operator Operating instructions ecoFIT pure 612 - 630. GB, IE. Publisher/manufacturer Vaillant GmbH. Berghauser Str. 40 D-42859 Remscheid Tel. +49 21 91 18 0 Fax +49 21 91 18 2810. Contents Contents 5 Troubleshooting .. 13. Detecting and rectifying 13. 1 Safety .. 3 Calling up (Live monitor) status Action-related warnings .. 3 codes .. 13. Intended use .. 3 6 Care and maintenance .. 14. General safety 4 Maintenance .. 14. 2 Notes on the documentation .. 7 Caring for the product .. 14. Observing other applicable Reading maintenance documents .. 7 messages .. 14. Storing 7 Checking the condensate drain Applicability of the 7 pipework and 14. 3 Product 7 7 14. Front view .. 7 Temporarily decommissioning Control 7 the 14. Displayed 8 Permanently decommissioning the 14. Information on the identification plate .. 8 8 Recycling and 14. Serial number .. 9 9 Guarantee and customer service .. 15. CE label .. 9.

2 15. 9. Customer 15. 4 10. Appendix .. 16. Operating concept .. 10. A Status codes 16. Basic 10. B Troubleshooting .. 16. Adjustment and display levels .. 10. Cabinet-type casing .. 10. Opening the isolator devices .. 10. Starting up the product .. 11. Switching on the product .. 11. Setting the heating flow temperature .. 11. Setting the hot water temperature .. 11. Switching off the product's functions .. 11. Guaranteeing the correct filling pressure of the heating system .. 12. Protecting the heating installation against frost .. 13. Switching the product to standby mode .. 13. 2 Operating instructions ecoFIT pure 0020230534_02. Safety 1. 1 Safety ing installations and for hot wa- Action-related warnings ter generation. Classification of action-re- Intended use includes the fol- lated warnings lowing: The action-related warnings observance of the operating are classified in accordance instructions included for the with the severity of the pos- product and any other system sible danger using the following components warning signs and signal words: compliance with all inspection Warning symbols and signal and maintenance conditions words listed in the instructions.

3 Danger! This product can be used by Imminent danger to life children aged from 8 years or risk of severe personal and above and persons with injury reduced physical, sensory or Danger! mental capabilities or lack of experience and knowledge if Risk of death from electric they have been given supervi- shock sion or instruction concerning Warning. use of the product in a safe way Risk of minor personal and understand the hazards in- injury volved. Children must not play Caution. with the product. Cleaning and Risk of material or envir- user maintenance work must onmental damage not be carried out by children unless they are supervised. Intended use Any other use that is not spe- There is a risk of injury or death cified in these instructions, or to the user or others, or of dam- use beyond that specified in this age to the product and other document shall be considered property in the event of im- improper use. Any direct com- proper use or use for which it mercial or industrial use is also is not intended.

4 Deemed to be improper. The product is intended as a Caution. heat generator for closed heat- Improper use of any kind is prohibited. 0020230534_02 ecoFIT pure Operating instructions 3. 1 Safety General safety Do not use any electrical information switches, mains plugs, door- Installation by bells, telephones or other competent persons only communication systems in the building. The installation, inspection, maintenance and repair of the If it is safe to do so, close the product, as well as the gas ratio emergency control valve or settings, must only be carried the main isolator. out by a competent person. If possible, close the gas isol- ator cock on the product. Danger caused by Warn other occupants in the improper operation building by yelling or banging Improper operation may present on doors or walls. a danger to you and others, and Leave the building immedi- cause material damage. ately and ensure that others Carefully read the enclosed do not enter the building.

5 Instructions and all other ap- Notify the gas supply com- plicable documents, particu- pany or the Emergency larly the "Safety" section and Service Provider the warnings. +44 (0) 800 111999 by tele- Only carry out the activities phone once you are outside for which instructions are of the building. provided in these operating Risk of death due to a instructions. blocked or leaking flue Risk of death from gas pipe escaping gas What to do if you smell flue gas What to do if you smell gas in in the property: the building: Open all accessible doors Avoid rooms that smell of and windows fully to provide gas. ventilation. If possible, open doors and Switch off the product. windows fully and ensure Inform a competent person. adequate ventilation. Do not use naked flames ( lighters, matches). Do not smoke. 4 Operating instructions ecoFIT pure 0020230534_02. Safety 1. Risk of death due to Risk of corrosion explosive and flammable damage due to materials unsuitable combustion Do not use or store explosive and room air or flammable materials ( Sprays, solvents, chlorinated petrol, paper, paint) in the in- cleaning agents, paint, adhes- stallation room of the product.

6 Ives, ammonia compounds, dust or similar substances may Risk of death due lead to corrosion on the product to changes to the and in the air/flue pipe. product or the product environment Ensure that the supply of combustion air is always free Never remove, bridge or of fluorine, chlorine, sulphur, block the safety devices. dust, etc. Do not tamper with any of the Ensure that no chemical sub- safety devices. stances are stored at the in- Do not damage or remove stallation site. any seals on components. Do not make any changes: Risk of material damage The product itself caused by frost to the gas, air, water and Ensure that the heating in- electricity supplies stallation always remains in to the entire flue gas install- operation during freezing con- ation ditions and that all rooms are to the entire condensate sufficiently heated. drain system If you cannot ensure the op- to the expansion relief valve eration, have a competent to the drain pipework person drain the heating in- to constructional condi- stallation.

7 Tions that may affect the operational reliability of the product 0020230534_02 ecoFIT pure Operating instructions 5. 1 Safety Risk of injury and material damage due to maintenance and repairs carried out incorrectly or not carried out at all Never attempt to carry out maintenance work or repairs on your product yourself. Faults and damage should be immediately rectified by a competent person. Adhere to the maintenance intervals specified. 6 Operating instructions ecoFIT pure 0020230534_02. Notes on the documentation 2. 2 Notes on the Control elements documentation 3. Observing other applicable documents 50. You must observe all operating instruc- tions enclosed with the system compon- ents. Storing documents 2 1. Keep this manual and all other applic- 1 Fault clearance 2 Operating but- able documents safe for future use. key tons 3 Display Applicability of the instructions Operator control panel These instructions apply only to: Product article number Article Gas Coun- number cil Number 1.

8 VU 126/6-3 0010020395 41-694-03. 50. (H-GB) 9. VU 156/6-3 0010020396 41-694-04. 2. (H-GB). 8. VU 186/6-3 0010020397 41-694-05 3. (H-GB). VU 256/6-3 0010020398 41-694-06 7. (H-GB) 4. VU 306/6-3 0010020399 41-694-07. (H-GB). 6. 3 Product description 5. Front view 1. 1 Current heating 3 Left- and right- flow temperat- hand selection ure, operating buttons 2 mode, fault code 4 and but- or additional in- ton formation 5 Fault clearance 2 Current assign- key 1 Control elements 2 Plate with serial ment of the right- number on the hand selection rear button 0020230534_02 ecoFIT pure Operating instructions 7. 3 Product description 6 Maximum out- 8 Current assign- Sym- Meaning Explanation put (only used ment of the left- bol for Austria, hand selection Burner anti-cyc- To avoid the Germany and button ling time is active need for frequent Switzerland) 9 Active operating switching on and 7 Access to the status off (increases the menu for addi- product's working tional information life).

9 Fault in the Fault in the Displayed symbols product product. Appears Sym- Meaning Explanation instead of the bol basic display. Burner operating Burner on correctly Information on the bar Current filling Permanently identification plate pressure of the on: Filling The identification plate is mounted on the heating system pressure in underside of the product in the factory. The dashed lines the permitted show the permit- range The identification plate keeps record of ted range Flashing: the country in which the product is to be Filling pres- installed. sure outside the permitted Information Meaning range on the identi- fication plate Heating mode Permanently active on: Heating Barcode with serial number mode heat requirement Serial number For quality control purposes;. Flashing: 3rd and 4th digits = year of Burner on in production heating mode For quality control purposes;. Hot water gener- Permanently 5th and 6th digits = week of ation active on: In draw-off production mode before For identification purposes.

10 Burner is on 7th to 16th digits = product Flashing: article number Burner on in For quality control purposes;. draw-off mode 17th to 20th digits = place of Maintenance re- Information on manufacture quired the maintenance ecoFIT pure Product designation message in the 2H, G20 2 Factory setting for type of "Live Monitor" kPa (20 mbar) gas and gas connection Summer mode pressure active Cat. Unit category Heating mode is Condensing Efficiency class of the boiler switched off technology in accordance with EC Dir- ective 92/42/EEC. Type: Xx3(x) Permissible flue gas connec- tions 8 Operating instructions ecoFIT pure 0020230534_02. Product description 3. Information Meaning Benchmark on the identi- fication plate Vaillant is a licensed member of the PMS Maximum water pressure in Benchmark Scheme. heating mode Benchmark places responsibilities on both PMW Maximum water pressure in manufacturers and installers. The purpose hot water handling mode is to ensure that customers are provided V/Hz Electrical connection with the correct equipment for their needs, W Max.