Example: bankruptcy

ELECTRIC TECHNICAL DATA SHEET RCEL Series Actuators

Remote Control RCEL SeriesElectric Actuators are engineeredto provide efficient, high perfor-mance automation of quarter turnvalves. The RCEL Series hasimproved reliability incorporatingall the best features. Standard enclosure IP-67, NEMA 4, 4x Squirrel cage, totally enclosed motor Standardized and color-coded wiring Manual override hand/auto declutch lever, automatic reset when motor is energized Handwheel designed for safe, efficient operation Mounting standardized to ISO-5211; removable drive bushing can be machined to match valve stem Wormgear drive for longer life and low maximum noise level of 50dB Indicator top mounted for continuous visual indication of valve position 20 watt internal heater to minimize condensation due to temperature and humidity changes Cam actuated, end of travel limit switches are easily adjusted to de-energize actuator for precise valve position Torque switch is cam actuated and factory set to provide over torque protection for valves, available i

Remote Control RCEL Series Electric Actuators are engineered to provide efficient, high perfor-mance automation of quarter turn valves. The RCEL Series has

Tags:

  Series, Sheet, Data, Electric, Technical, Lcers, Electric technical data sheet rcel series

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of ELECTRIC TECHNICAL DATA SHEET RCEL Series Actuators

1 Remote Control RCEL SeriesElectric Actuators are engineeredto provide efficient, high perfor-mance automation of quarter turnvalves. The RCEL Series hasimproved reliability incorporatingall the best features. Standard enclosure IP-67, NEMA 4, 4x Squirrel cage, totally enclosed motor Standardized and color-coded wiring Manual override hand/auto declutch lever, automatic reset when motor is energized Handwheel designed for safe, efficient operation Mounting standardized to ISO-5211; removable drive bushing can be machined to match valve stem Wormgear drive for longer life and low maximum noise level of 50dB Indicator top mounted for continuous visual indication of valve position 20 watt internal heater to minimize condensation due to temperature and humidity changes Cam actuated, end of travel limit switches are easily adjusted to de-energize actuator for precise valve position Torque switch is cam actuated and factory set to provide over torque protection for valves.

2 Available in size RCEL-15 thru RCEL-250 Mechanical limit stops designed to prevent over-travel of quarter turn applications Valve backdrive is prevented by a rolled steel wormgear and aluminum bronze wormwheel CSA C/US Approval on 120 VAC onlyFEATURESTECHNICAL data SHEETELECTRICRCEL Series ActuatorsEXPE xplosion & Water Proof Enclosure Class I C & D / Class II E, F & G Exd IIB T4 IP67 DCM 24 VDC Motor (RCEL-6 thru RCEL-28)ACM 24 VAC Motor (RCEL-6 thruRCEL-28)ALSA uxiliary Limit Switches 2 SPDT switches (6 aux switches max)EXTE xtended Travel Angle120 to 360 (RCEL-6 thruRCEL-100)LCUL ocal Control Unit (NEMA-4)local/remote selector switchopen/stop/close selector switchLCUL ocal Control Unit (NEMA-4)KEYw/key with key lockPIU1K Ohm Feedback PotentiometerCPTC urrent Position Feedback Transmitter 4-20mA DC outputDCTVDC Position Feedback Transmitter1-5 VDC, 0-5 VDC and 0-10 VDCPCUP roportional Control Unit4-20mA, 1-5 VDC or 0-10 VDC inputIMSI ntegral Motor Starterincludes reversing contactorsand step down transformerCLCR epeat Cycle Timer for cycle length controlATSA uxiliary Torque Switches 2 SPDT switches (RCEL-15 thru RCEL-250)Remote Control Inc.

3 Box 355 North Kingstown, RI 02852 Phone 401-294-1400 Fax401-294-3388 Email OPTIONS STANDARD SPECIFICATIONSMax Operating TimeDuty Cycle Rated Current Amps/Locked Rotor Amps TYPEO utput Torque60/50 hz30 Pounds90 IP67, Nema 4, 4x Ambient -20 to +158 Fahrenheit300 Fahrenheit for 1 hourPower Supply120/220 VAC 1-Phase380/440 VAC 3-PhaseControl Power110/220 VAC 1-Phase, 50/50 HzDuty CycleSee Performance ChartTorque Switches(2) Open/Close (RCEL-15 thru RCEL-250)Limit Switches(2) Open/Close, 250 VAC 16A RatingStall ProtectionInternal Thermal ProtectionOpen 300 F/Close 207 FTravel Angle90 5 IndicatorContinuous Position IndicatorManual OverrideHAND/AUTO Declutching MechanismSelf LockingProvided by means of Worm GearingMechanical StopsExternal Adjustable ScrewsSpace Heater20 Watt (24/120/220 VAC and 24 VDC)Anti-CondensationConduit EntriesTwo 3/4 Moly (EP)

4 TypeMaterialsSteel, Aluminum Alloy, Aluminum BronzeSurface TreatmentAnodizingExternal CoatingDry Powder, Epoxy-PolyesterPERFORMANCETECHNICAL data SHEETRCEL SeriesMODEL RCEL-6 RCEL-9 RCEL-15 RCEL-19 RCEL-28 RCEL-38 RCEL-50 RCEL-60 RCEL-80 RCEL-100 RCEL-150 RCEL-200 RCEL-250 ISO 5211 FLANGEF-07F-07 / F-10F-10 /F-12F-12 / / / / M10M10 / M/12M12 / M16M20 Thread / / / B dimension is metric. All other dimensions are data SHEETRCEL SeriesCUSTOMERDETAILC ompany _____Job _____Street _____City _____Item_____Zip _____Tag _____Attention _____VALVE INFORMATIONMfg _____Type _____ Size _____ Fig No _____Valve rotation to close (as viewed from top) _____ Clockwise _____ Counter-clockwise _____ Max.

5 Required torque (with safety) _____ Inch REQUIREMENTSA pplication _____ Open/Close Service _____ Modulating Service _____ Other _____Ambient Temperature _____ F to _____FSupply Voltage _____ volt AC _____Hz, 1- phase or 3-phase _____ volt DCControl Voltage _____ volt AC _____ Hz, 1- phase or _____volt DC. (When IMS is required)OPTIONAL ITEMS (AS REQUIRED)Position Feedback Transmitter _____(4-20A, 0-5vdc, 1-5vdc or 0-10vdc)Proportional Control Unit _____(4-20mA, 1-5vdc or 0-10vdc)Aux. Limit Switch (6-max) _____Integral Motor Starter _____Local Control Unit_____Delay On/Off Relay _____Cycle Timer Control _____Other _____APPLICATION DATATECHNICAL data SHEETRCEL SeriesRemote Control Inc.

6 Box 355 North Kingstown, RI 02852 Phone 401-294-1400 Fax401-294-3388 Email