Application and DesignEVH-501D is a Florida Product Approved and Miami-Dade Qualified stationary vertical blade wind driven rain extruded aluminum louver designed to protect air intake and exhaust openings in building exterior walls. EVH-501D is tested in accordance with AMCA 500-L Air Performance, Water Penetration and Wind Driven Rain. EVH-501D is tested in accordance with AMCA 540 Test Method for Louvers Impacted by Wind Borne Debris (Basic Protection, Missile Level D and Enhanced Protection, Missile Level E). EVH-501D is tested in accordance with AMCA 550 Test Method for High Velocity Wind Driven Rain Resistant Louvers. EVH-501D is licensed to bear the AMCA seal allowing design professionals to select and apply with confidence. EVH-501D is tested and qualified per the following Florida test protocols: TAS 201 (Large Missile Impact), TAS 202 (Uniform Static Air Pressure) and TAS 203 (Cyclic Wind Loading). Per Miami-Dade EVH-501D may be installed in locations where the room behind the louver is NOT designed to drain water penetrating into the room or the room will house non-water resistant or water proof equipment, components or ConstructionFrame Heavy gauge extruded aluminum, 5 in.

PERFORMANCE DATA EVH-501D Florida Product Approval No.: 19277.1 Miami-Dade, FL NOA No.: 15-0415.05 EXP. 8/6/2020 AMCA 540 …

Tags:

  Greenheck, D150, Evh 501d

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of EVH-501D - Greenheck

1 Application and DesignEVH-501D is a Florida Product Approved and Miami-Dade Qualified stationary vertical blade wind driven rain extruded aluminum louver designed to protect air intake and exhaust openings in building exterior walls. EVH-501D is tested in accordance with AMCA 500-L Air Performance, Water Penetration and Wind Driven Rain. EVH-501D is tested in accordance with AMCA 540 Test Method for Louvers Impacted by Wind Borne Debris (Basic Protection, Missile Level D and Enhanced Protection, Missile Level E). EVH-501D is tested in accordance with AMCA 550 Test Method for High Velocity Wind Driven Rain Resistant Louvers. EVH-501D is licensed to bear the AMCA seal allowing design professionals to select and apply with confidence. EVH-501D is tested and qualified per the following Florida test protocols: TAS 201 (Large Missile Impact), TAS 202 (Uniform Static Air Pressure) and TAS 203 (Cyclic Wind Loading). Per Miami-Dade EVH-501D may be installed in locations where the room behind the louver is NOT designed to drain water penetrating into the room or the room will house non-water resistant or water proof equipment, components or ConstructionFrame Heavy gauge extruded aluminum, 5 in.

2 X in. nominal wall thicknessBlades Vertical rain resistant design, heavy gauge extruded 6063-T5 aluminum, in. nominal wall thickness, positioned on approximately in. centers Construction .. Mechanically fastenedBirdscreen 3/4 in. x flattened expanded aluminum removable frame, inside mount (rear)Finish MillMinimum RoughOpening Size 12 in. W x 12 in. HMaximum RoughOpening Size Unlimited W x Unlimited H Multi-wide assemblies are permitted without any additional reinforcing provided the rough opening height is 120 in. or less Multi-high assemblies are permitted provided suitable load bearing structure is provided (by others) at each louver section(s) head and sill condition so that the louvers section(s) may installed in accordance with the instructions shown hereinMaximum SingleSection Size 72 in. W x 120 in. H or 120 in. W x 72 in.

3 HOptions (at additional cost) A variety of bird and insect screens Blank-off panels Extended sill Filter racks Flanged frame Security bars*Width and height dimensions furnished approximately 3/4 inch under Qualified Wind-Driven Rain LouverFlorida Product Approval No.: Miami-Dade, FL NOA No.: EXP. 8/6/2020 AMCA 540 and 550 ListedMaximum Wind-load: 130 PSFEVH-501D A variety of architectural finishes including: Clear anodize Integral color anodize Baked enamel paint Kynar paintEVH-501 DPERFORMANCE DATAF lorida Product Approval No.: Miami-Dade, FL NOA No.: EXP. 8/6/2020 AMCA 540 and 550 ListedMaximum Wind-load: 130 PSFThe AMCA Water Penetration Test provides a method for comparing various louver models and designs as to their efficiency in resisting the penetration of rainfall under specific laboratory test conditions. The beginning point of water penetration is defined as that velocity where the water penetration curve projects through oz.

4 Of water (penetration) per sq. ft. of louver free area. *The beginning point of water penetration for Model EVH-501D is above 1250 fpm free area velocity. These performance ratings do not guarantee a louver to be weather-proof or stormproof and should be used in combination with other factors including good engineering judgement in selecting Resistance (Standard Air - 075 lb/ft3)Model EVH-501D resistance to airflow (pressure drop) varies depending on louver application (air intake or air exhaust). Free area velocities (shown) are higher than average velocity through the overall louver size. See louver selection information. (Test Figure )Weather louvers shall be classified by their ability to reject simulated rain. The table shows different classifications based on the maximum simulated rain penetration per square meter (square feet) of louver. Water penetration rating at a given louver face velocity is determined by the water penetration while the louver is subjected to a selected simulated rainfall rate and wind Rain PerformanceDischarge Loss Coefficient Class (Intake) = 2 Water Penetration Test Size 48 in x 48 in Test Duration of 15 min Discharge Loss Coefficient ClassificationsWind-driven Rain Penetration ClassesClassDischarge Loss and to to to to and to Fan Corporation certifies that the EVH-501D louvers shown herein are licensed to bear the AMCA Seal.

5 The ratings shown are based on tests and procedures performed in accordance with AMCA Publication 511 and comply with the requirements of the AMCA Certified Ratings Program. The AMCA Certified Ratings Seal applies to air performance, water penetration, and wind-driven rain Fan Corporation certifies that the EVH-501D louvers shown herein are approved to bear the AMCA Listing Label. The Ratings shown are based on tests and procedures performaned in accordance with AMCA Publications and comply with the requirements of the AMCA Listing Label Program. The AMCA Listing Label applies to Wind Borne Debris Impact Resistant and High Velocity Rain Resistant (3 in/hr) Rainfall & 13 m/s(29 mph) Wind Velocity200mm/h (8 in/hr) Rainfall & 22 m/s(50 mph) Wind VelocityVentilation AirCore Velocitym/s (fpm)Water PenetrationEffectiveness%Water PenetrationClassificationVentilation AirCore Velocitym/s (fpm)Water PenetrationEffectiveness%Water (0) (0) (98) (98) (196) (196) (295) (295) (393) (393) (492) (492) (590) (590) (688) (688) (782) (787) (875) (872) (989) (975) DATAFree Area Chart (sq.)

6 Ft.)Louver Height InchesLouver Width in Height InchesLouver Width in Area Chart (sq. ft.)Florida Product Approval No.: Miami-Dade, FL NOA No.: EXP. 8/6/2020 AMCA 540 and 550 ListedMaximum Wind-load: 130 PSFEVH-501 DINSTALLATION DETAILSM aximum Size and Installation InformationModel EVH-501D is a Miami-Dade Qualified and Florida Product Approved louver and must be installed in accordance with the installation instructions shown herein. Model EVH-501D is qualified for installation within concrete/masonry, steel, aluminum or wood substrate. Model EVH-501D is tested and qualified to withstand positive and negative wind pressure loads up to 130 PSF. The maximum single section width is 120 in. (72 in. height maximum). The maximum single section height is 120 in. (72 in. width maximum). Multi-wide assemblies are permitted without any additional reinforcing provided the maximum rough opening height is not exceeded.

7 Multi-high assemblies are permitted provided suitable load bearing structure is provided (by others) at each louver section(s) head and sill condition so that the louver section(s) may be installed in accordance with the instructions shown Rough Opening Size12 in W x 12 in HMaximum Rough Opening Single Section Size 72 3/4 in W x 120 3/4 in H or120 3/4 in W x 72 3/4 in HFlorida Product Approval No.: Miami-Dade, FL NOA No.: EXP. 8/6/2020 AMCA 540 and 550 ListedMaximum Wind-load: 130 PSFPRODUCT DETAILSEVH-501 DFlorida Product Approval No.: Miami-Dade, FL NOA No.: EXP. 8/6/2020 AMCA 540 and 550 ListedMaximum Wind-load: 130 PSFFASTENER CHARTEVH-501 DFlorida Product Approval No.: Miami-Dade, FL NOA No.: EXP. 8/6/2020 AMCA 540 and 550 ListedMaximum Wind-load: 130 PSFEVH-501 DNovember 2017 Copyright 2017 Greenheck Fan CorporationGreenheck Fan Corporation reserves the right to make product changes without notice Finish TypeDescription/ApplicationColor SelectionStandard Warranty (Aluminum)2-coat 70% KYNAR 500 /HYLAR 5000 AAMA 2605 Dry film thickness 1 2 mil (AKA: Duranar , Fluoropon , Trinar , Flouropolymer, Polyvinylidene Fluoride, PVDF2) Best.

8 The premier finish for extruded aluminum Tough, long-lasting coating has superior color retention and abrasive properties Resists chalking, fading, chemical abrasion and weathering Standard Colors: Any of the 24 standard colors shown can be furnished in 70% or 50% KYNAR 500 /HYLAR 5000 or Baked Enamel 2-Coat Mica: Greenheck offers 9 standard 2-coat Mica colors Other colors are available Consult Greenheck for possible extra cost when selecting non-standard colors or special finishes 10 Years(Consult Greenheck for availability of extended warranty)2-coat 50% KYNAR 500 /HYLAR 5000 AAMA 2604 Dry film thickness 1 2 mil (AKA: Acroflur , Acrynar ) Better. Tough, long-lasting coating has excellent color retention and abrasive properties Resists chalking, fading, chemical abrasion and weathering 5 YearsBaked Enamel AAMA 2603 Dry film thickness 0 8 mil (AKA: Acrabond Plus , Duracron ) Good. Provides good adhesion and resistance to weathering, corrosion and chemical stain 1 YearIntegral Color Anodize AA-M10C22A42 (>0 7 mil) Two-step anodizing is produced by following the normal anodizing step with a second, colorfast process Light, Medium or Dark Bronze; Champagne.

9 Black5 yearsClear Anodize 215 R-1 AA-M10C22A41 (>0 7 mil)Clear, colorless and hard oxide aluminum coating that resists weathering and chemical attack Clear5 yearsClear Anodize 204 R-1 AA-M10C22A31 (0 4-0 7 mil) Clear, colorless and hard oxide aluminum coating that resists weathering and chemical attack Clear1 YearIndustrial coatingsGreenheck offers a number of industrial coatings such as Hi-Pro Polyester, Epoxy, and Permatector Consult a Greenheck Product Specialist for complete color and application information Consult GreenheckMill Materials may be supplied in natural aluminum or galvanized steel finish when normal weathering is acceptable and there is no concern for color or color change n/aOPTION DRAWINGSF inishes meet or exceed AAMA 2605, AAMA 2604, and AAMA 2603 requirements. Please consult for complete information on standard and extended paint warranties. Paint finish warranties are not applicable to steel Product Approval No.

10 : Miami-Dade, FL NOA No.: EXP. 8/6/2020 AMCA 540 and 550 ListedMaximum Wind-load: 130 PSF