Transcription of FEATURES - hubbellcdn
1 Page 1/5 Rev. 07/08/21DL_LSN D_SPEC_0603405 LSN D SeriesSINGLE-PHASE CENTRAL LIGHTING INVERTERS 2021 Dual-Lite, a division of Hubbell Lighting, Inc. Specifications subject to change without notice. 701 Millennium Blvd Greenville, SC 29607 / Tel: 864-678-1000 / Website: Uninteruptible emergency AC power system 90 minute emergency operation supplied standard No Break design transfers the load instantaneously when normalpower is interrupted Single-phase For normally-on and normally-off loads User interface module includes multiple LED indicators and audiblealarms to provide system status Overload and short circuit protection BROCHURE DIMENSIONAL DRAWINGSDATE:LOCATION:TYPE:PROJECT.
2 APPLICATION Indoor Commercial Indoor IndustrialOPERATION Automatic, programmable self-diagnosticoperation When normal utility-supplied power ispresent, the LSN model central lightinginverter provides load-side line conditioningwith brownout protection, and charges thesystem batteries when required. When utility-supplied power is interrupted,or the voltage varies from predeterminedlimits, the system will automatically andinstantaneously transfer to emergency modewithout interruption to connected loads. DC battery-derived emergency power isinverted to AC power and supplied in apure sine wave output form for 90 minutes(standard run time).
3 A low voltage battery disconnect circuitprevents deep discharge damage to thebatteries during prolonged power normal power is restored the systemwill automatically restart, providing powerto connected loads and recharging thebatteries. The charging circuit will bring the batteries tofull recharge within UL time Two years full on all components from dateof shipment when a Factory Start-Up isperformed; one year full when a FactoryStart-Up is not performed. Batteries are covered under a separatewarranty:BATTERY WARRANTY INFORMATION Batteries must be connected to anenergized charging circuit within 90 daysfrom date of shipment or warranty is void.
4 Start-Up must be performed by anAuthorized Service Center within 6 monthsof inverter shipment and will increase theinverter warranty to 2 years. Order quantityof 1 per system. Systems powered up byothers are done so at their own Steel Cabinet Light grey paint finish Locking cabinetry and password-protecteduser interface for security Louvers at front and top of cabinet Input power entry point is from the cabinettop. Bottom channels for lifting straps Wall brackets for anchoring. Servicing is accessible from cabinet front.
5 CERTIFICATIONS/COMPLIANCES UL 924 Listed, Emergency Lighting and Power Equipment (standard 90 minute run time), type S battery, all voltages except 347V UL & CUL 1778 Listed, Uninterruptible Power Supply Equipment (alternate run times; type G batteries; 347V input/output) ANSI : ANSI (Cat. A & B) FCC class A National Electrical Code (NFPA 70) Life Safety Code (NFPA 101) NFPA 111 (Stored Emergency Power Supply Systems - SEPSS) NEMA Type 1 Cabinetry OSHA, state and local codes CATALOG #:Self-Testing/Self-Diagnostic Electronics SystemSPECTRON Battery TypeFullPro-rataS (VRLA lead-calcium)1 year9 yearsG (VRLA lead-calcium)1 year14 yearsNFPANFPA LSN D SeriesSINGLE-PHASE CENTRAL LIGHTING INVERTERS 2021 Dual-Lite, a division of Hubbell Lighting, Inc.
6 Specifications subject to change without notice. 701 Millennium Blvd Greenville, SC 29607 / Tel: 864-678-1000 / Website: 2/5 Rev. 07/08/21DL_LSN D_SPEC_0603405 ORDERING GUIDEE xample: D120-01S120/208-N2007U-EMLCATALOG #DATE:LOCATION:TYPE:PROJECT:CATALOG #:D ModelInput Voltage 2 CapacityBattery TypeOutput Voltage (VAC) 2,3,4 Output Circuit Breaker TypeOutput Circuit Breaker Voltage RatingOutput Circuit Breaker Ampere Rating 6 Output Circuit Breaker Quantity 7 Output Circuit Breaker Supervision DLSN Central Lighting S10-year VRLA Lead-CalciumG20-year VRLA Lead-Calcium120120/208120/240 5120/277277347 BlankNormally OnNNormally OffA120 VACB240 VACC277 VACD208 VAC15202530354050608001 - 20 BlankMonitoredUUnmonitoredOptions And AccessoriesEMLE mail DeviceRSPR emote Status PanelSMTS ystem Monitoring Terminal Including Emergency
7 Power Off TerminalARAlternate Runtime 8 SBCS hort Battery Cabinet 9 IBSI nternal Maintenance Bypass Switch (Make Before Break)C1010 Amp Charger Upgrade 10C2020 Amp Charger Upgrade 11 SSeismic Qualified 12 AccessoriesDSFK_Seismic Kit 12 Service OptionsFSLF actory Start-Up 13 Notes:1 Requires a provided external transformer for 208 VAC or 240 VAC to Specifications table (page 4) for available Input/Output voltage voltages available. Consult transformer may be may not exceed 50% of the system s total rating on any 120 VAC Off circuit breakers: a maximum rating of 20 amps7 Normally On circuit breakers: a maximum of 14 monitored, single pole positions or 20 unmonitored, single pole positions may be specified.
8 Normally Off circuit breakers: a maximum of 8 single pole positions (monitored or unmonitored) may be runtime in minutes when ordering. Example: with , , , , , and Series with S batteries on KVA - on KVA - Series. Not available with 120V input on and above. Not available with 208V input on KVA and above. Not available with 240V input on KVA and S Battery in standard height cabinet only; See system configuration for 90-minute run Start-Up is non-cancellable / non-returnable and must be performed by an Authorized Service Center within 6 months of battery shipment to increase the inverter warranty to 2 years.
9 Order a quantity of 1 per system. Systems powered up by others are done so at their own risk. LSN D SeriesSINGLE-PHASE CENTRAL LIGHTING INVERTERS 2021 Dual-Lite, a division of Hubbell Lighting, Inc. Specifications subject to change without notice. 701 Millennium Blvd Greenville, SC 29607 / Tel: 864-678-1000 / Website: 3/5 Rev. 07/08/21DL_LSN D_SPEC_0603405 OPTIONS AND ACCESSORIES INFORMATIONDATE:LOCATION:TYPE:PROJECT:CA TALOG #:SuffixOptionsDescriptionEMLE mail DeviceA device that automatically notifies the user of system test results and alarm conditions.
10 The Email Device sends detailed notifications to up to six pre-programmed email addresses. Requires customer supplied CAT5 cable connected to user network. RSPR emote Status PanelProvides remote annunciation for the LSN inverter to indicate inverter and alarm status. Owner-installed option. Must be installed within 1,000 ft. of the LSN inverter. Seven-conductor-minimum, 22 AWG wire for connection from options board to Remote Status Panel must be supplied by Monitoring Terminals including Emergency Power Off TerminalProvides connections points for Inverter and Alarm Relays (low power contacts change status with either inverter or alarm events), and Remote Status Panel (allows the addition of an RSP at any time).