Fiberglass - Cooper Industries

NominalDesign LoadMaximumPart SizeTorquein. mmLbs. N mBFV20081/2(15)300( )10( )BFV20093/4(20)300( )10( )BFV20101(25)300( )10( )BFV201111/4(32)300( )10( )BFV201211/2(40)300( )10( )BFV20132(50)300( )10( )BFV201421/2(65)300( )10( )BFV20153(80)300( )10( )BFV201631/2(90)300( )10( )BFV20174(100)300( )10( )BFV2000 SeriesNon-Metallic Pipe Clamps For rigid and PVC conduit. Standard hardware includes slotted round head machine screw and square nut in 316 stainless steel Design Load Safety Factor of 3 Material: Glass reinforced PPO Not recommended for vertical installation without additional Stop-Lock Kit.

BFP2400 Series 2-Hole Pipe Clamps • Design Load Safety Factor of 3 • Material: Glass Reinforced Polyester BFV751 & BFV751J Beam Clamp • Design Load Safety Factor of 3

Tags:

  Fiberglass, Industreis, Cooper industries, Cooper, Reinforced, Beam

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of Fiberglass - Cooper Industries

1 NominalDesign LoadMaximumPart SizeTorquein. mmLbs. N mBFV20081/2(15)300( )10( )BFV20093/4(20)300( )10( )BFV20101(25)300( )10( )BFV201111/4(32)300( )10( )BFV201211/2(40)300( )10( )BFV20132(50)300( )10( )BFV201421/2(65)300( )10( )BFV20153(80)300( )10( )BFV201631/2(90)300( )10( )BFV20174(100)300( )10( )BFV2000 SeriesNon-Metallic Pipe Clamps For rigid and PVC conduit. Standard hardware includes slotted round head machine screw and square nut in 316 stainless steel Design Load Safety Factor of 3 Material: Glass reinforced PPO Not recommended for vertical installation without additional Stop-Lock Kit.

2 Kit includes one square washer, channel nut and hex head cap (Stop-Lock Kit on page 191) BFVSL-3/8for 3/8 -16 hardware or BFVSL-1/2for 1/2 -13 hardware. Mount kit below clamp when used in vertical strut to prevent clamp slipping. If non-metallic hardware is required, add N to the part number. Example: BFV2008 NBFV100 thru BFV300 Adjustable Pipe Clamps Completely Non-Metallic Adjustable to & Metric Pipe Diameters Fits OD Sizes 3/4 ( )to 31/2 ( ) Easy To Install No Special Tools Required Design Load Safety Factor of 3 Material: Glass reinforced Polyurethane Not recommended for vertical installation without additionalStop-Lock Kit.

3 Kit includes one square washer, channel nutand hex head cap (Stop-Lock Kit on page 191) BFVSL-3/8for 3/8 -16 hardware or BFVSL-1/2for 1/2 -13 hardware. Mount kit below clamp when used in vertical strut to prevent clamp N mBFV1001/2 - 11/2(15- 40).75 - ( - )135(.60)10( )BFV20011/2- 2(40 - 51) - ( - )135(.60)36( )BFV30021/2 - 3(63 - 76) - ( - )145(.64)36( )Design LoadDesign LoadStop-Lock Kitfor verticalinstallationStop-Lock Kitfor verticalinstallationFiberglass MaterialsReference page 183for general fitting SystemsBFP2400 Series 2-Hole Pipe Clamps Design Load Safety Factor of 3 Material: Glass reinforced PolyesterBFV751 & BFV751J beam Clamp Design Load Safety Factor of 3 BFV751J (clip included) must be used when installed ontapered flange beams.

4 Material: Glass reinforced Polyurethane Setscrew material: Stainless Steel 316 ASTM F593 Group 2, S4 Part Hanger RodDesign LoadTorqueSize ALbs. N mBFV751-3/83/8 -16500( )10(13)BFV751J-3/83/8 -16500( )10(13)BFV751-1/21/2 -13500( )10(13)BFV751J-1/21/2 -13500( )10(13)BFV751-5/85/8 -11500( )10(13)BFV751J-5/85/8 -11500( )10(13)41/4 ( )11/8 ( )1 ( )1/2 -13 x 2 ( )ScrewTapped forHanger RodSize ABFV751(ClampOnly)BFV751J(Clamp andRetainer Clip)BFVATR3/8 &BFPUATRHN(Order Separately)3 ( ) mm (50)23/8(60)51/2(140)115( )BFP2400-33(80)31/2(89)63/4(171)130( )BFP2400-44(100)41/2(114)73/4(197)150( )BFP2400-66(150)65/8(168)10(254)

5 150( )15/8 ( )13/32 ( )Hole LoadAFiberglass MaterialsReference page 183 for general fitting Systems193 BFV3104 Series Clevis Hangers Design Load Safety Factor of 3 at 120 F (49 C). Insulation may be required at higher temperatures. Order hanger rod and nuts separately. Material: Glass reinforced Polyurethane For BFV3104-1 thru BFV3104-6 Material: Glass reinforced Polyester & Vinyl Ester For BFV3104-8 thru BFV3104-12 NominalHangerDesignPart mmin. mmin. mmLbs. kNBFV3104-11(50)11/2(38)41/4(108)11/4(32 )1/2 -13670( )BFV3104-11/211/2(65)2(51)51/8(130)11/4( 32)1/2 -13670( )BFV3104-22(50)21/2(63)61/2(165)11/4(32) 1/2 -13730( )BFV3104-21/2, 3, 421/2-4(65-100)51/8(130)10(254)11/2(38)1 /2 -131150( )BFV3104-66(150)63/4(171)125/16(313)2(51 )1/2 -131170( )NominalHangerDesignPart CRodLoadSizeSizein.

6 Mmin. mmin. mmin. mmLbs. kNBF*3104-88(200)91/4(235)165/8(422)3(76 )5/8 -11350( )BF*3104-1010(250)113/8(289)197/8(505)4( 101)5/8 -11450( )BF*3104-1212(300)131/2(343)223/8(568)5( 127)5/8 -11600( )BFV3104-1 thru BFV3104-6 BFV3104-8 thru BFV3104-12 AABBCCBFV755 beam Clamp Design Load Safety Factor of 3 Material: Glass reinforced Polyurethane Setscrew material: Stainless Steel 316 ASTM F593 Group 2, S4 Part Hanger RodDesign LoadTorqueSize ALbs. N mBFV755-3/83/8 -16400( )10(13)BFV755-1/21/2 -13400( )10(13)3 ( )3/4 ( )Tapped forHanger RodSize A25/8 ( )1/2 -13 x 2 ( )Screw*Specify P for polyester or V for Vinyl MaterialsReference page 183for general fitting Systems