Example: biology

Fiberglass Underground Tanks For Septic …

Fiberglass Underground TanksFor Septic ApplicationsAs consumers and industries become increasingly accountable to meetecological requirements for Underground collection and storage of liq-uids and other materials, Xerxes Corporation continues to be in theforefront with innovative solutions. Xerxes Fiberglass -reinforced plastic(FRP) Tanks offer a superior option for Underground collection and storageof septage, including Tanks for recirculation, dosing, holding and pumptank applications . Manufactured of high-quality resin and glass, Xerxestanks have a unique integral-rib design, making them structurallystrong yet lightweight. They are, therefore, easy to ship and easy toinstall.

Fiberglass Underground Tanks For Septic Applications As consumers and industries become increasingly accountable to meet ecological requirements for underground collection and storage of liq-

Tags:

  Applications, Fiberglass, Underground, Tanks, Septic, Fiberglass underground tanks for septic, Fiberglass underground tanks for septic applications

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of Fiberglass Underground Tanks For Septic …

1 Fiberglass Underground TanksFor Septic ApplicationsAs consumers and industries become increasingly accountable to meetecological requirements for Underground collection and storage of liq-uids and other materials, Xerxes Corporation continues to be in theforefront with innovative solutions. Xerxes Fiberglass -reinforced plastic(FRP) Tanks offer a superior option for Underground collection and storageof septage, including Tanks for recirculation, dosing, holding and pumptank applications . Manufactured of high-quality resin and glass, Xerxestanks have a unique integral-rib design, making them structurallystrong yet lightweight. They are, therefore, easy to ship and easy toinstall.

2 Rustproof and long-lasting, Xerxes offers customers a mainte-nance-free, cost-effective Fiberglass tank, a preferable choice to precastor cast-in-place reinforced concrete in Septic applications because afiberglass tank is a nonpermeable storage container. Xerxes also man-ufactures the RST-II, a Fiberglass Septic tank specifically designed forresidential applications . The RST-II is available in 1,000-gallon and1,500-gallon models. (See separate literature for details.)Xerxes four strategically located manufacturing facitities givecustomers prompt delivery and quality service. Xerxes manufacturescustom-designed Tanks for Septic applications , offering great flexibilityfor customers applications Municipalities Public parks Recreation sites Rural developments Sanitary stations Rest areas Private RV parks Truck stops Resorts24-inch access opening30-inch access opening24-inch access opening for effluent filter (vault)

3 Inlet teeTypical Septic Tank Design 6004 6 -11 7/8 5001,0004 11 -3 7/8 7001,5004 16 - 0 1,0001,5006 10 -7 1/4 8002,0006 13 -53/4 1,0003,0006 16 -4 1/4 1,2004,0006 21 -11 1/8 1,6005,0006 26 -5 1,9006,0006 30 -8 3/4 2,2002,0008 9 -1/2 9003,0008 12 -3 1,2004,0008 15 -1/2 1,4005,0008 17 -8 1/2 1,7006,0008 20 -61/2 2,0007,0008 23 -1 2,2008,0008 26 -1/2 2,5009,0008 28 -9 2,70010,0008 31 -6 1/2 3,00011,0008 34 -4 3,20012,0008 37 -1/2 3,50013,0008 41 -2 4,00014,0008 43 -11 1/2 4,20015,0008 46 -9 4,50010,00010 21 -5 1/4 3,20011,00010 22 -9 3/4 3,40012,00010 24 -1/4 3,60013,00010 25 -6 3/4 3,80014,00010 26 -11 1/4 4,00015,00010 29 -5 3/4 4,50020,00010 37 -8 3/4 5,70022,00010 42 -3/4 6,60025,00010 47 -6 3/4 7,90030,00010 55 -93/4 9,40035,00010 64 -3/4 10,50040,00010 73 -81/4 12,10020,00012 29 -4 9,20025,00012 35 -7 10,60030,00012 43 -1 12,50035,00012 49 -4 13,90040,00012 54 -4 15,00048,00012 65 -7 17,70050,00012 68 -1 18,300 Available In single-wall, double-wall and triple-wall models In 600-gallon to 50,000-gallon sizesStandard Features Nonpermeable Rustproof, long-lasting Fiberglass Integral-rib design for added strength and robustness Easy to ship and easy to install Designed for H-20 axle loadsOptional Features Inlet and outlet piping Inspection opening Openings for effluent filters (vaults)

4 Baffles/Partition walls Baffle/Partition-wall penetrations Sanitary tees (influent or effluent) Ladders (FRP or aluminum) FRP hold-down straps Concrete deadmen Pump platforms Tank-tightness testingNote:*The actual working capacity will fluctuate depending on placement of effluent Capacity (gallons)*Diameter Length Shipping Weight (pounds)Tank DataGuide Specifications Single-Wall FRP Tank for Septic UseShort FormThe contractor shall provide single-wall Fiberglass -reinforced plastic(FRP) Underground storage tank as shown on tank , dimensions, fitting sizes and locations, and optionalaccessories shall be as shown on tank drawings. The tank shall beas manufactured by Xerxes shall be tested and installed according to the XerxesInstallation Manual and Operating Guidelines for Single-WallFiberglass Underground Wastewater Tanks in effect at time ofeach FormPart I: General Quality Assurance A.

5 Acceptable Manufacturer: Xerxes Corporation, Minneapolis, Minnesota B. Manufacturing Standards:1. Manufacturer shall manufacture the tank shell to the appli-cable requirements of Underwriters Laboratories Standard Tank manufacturer shall be in the business of manufactur-ing Tanks to UL 1316 standards. Submittals: Contractor shall submit to the engineer _____copies of shop drawings for each tank and _____ copies of manufacturer s II: Single-Wall Fiberglass Underground Tanks A. Loading Conditions: Tank shall meet the following designcriteria:1. Internal Load: Tank shall be designed to withstand a 5-psigair-pressure test (3 psig for a 12-foot tank) with a 5:1 safety Surface Loads: Tank shall withstand surface H-20 axle loadswhen properly installed according to manufacturer s currentinstallation External Hydrostatic Pressure and Burial Depth: Tank shallbe capable of being buried in ground with 7 feet of overburden,the hole fully flooded and a safety factor of 5:1 against Tank shall support accessory equipment such as inlet andoutlet piping, effluent-filter chamber, ladders and baffles asshown on tank drawings and when installed according to tankmanufacturer s Product Storage:1.

6 Tank shall be capable of storing septage limited to the collec-tion and storage of human solid or liquid organic Tank shall be vented to atmospheric pressure as the tank isnot designed as a pressure Materials:1. Tank shall be manufactured of 100% resin and glass-fiberreinforcement, with no sand fillers and no exposed glass fibers. 2. Resin used in tank and accessories shall be premium isophthalic polyesterD. Tank Dimentions:1. Tank shall have a nominal outside diameter of Tank shall have an approximate overall length of AccessoriesA. Piping:1. Schedule 40 PVC or FRP pipe shall be used for inlet and outlet piping. 2. All piping shall be factory sealed to enable field tightnesstesting with at least one piping opening provided with a thread-ed fitting for connecting a pressure test Access Openings:1.

7 All access openings 24 inches in diameter or larger, shall bemanufactured of All access openings shall be factory sealed to enable fieldtightness (s) shall be shown on tank Optional riser extensions shall be FRP or Optional Anchor Straps:1. Straps shall be FRP anchor straps as supplied by tank Number and location of straps shall be shown on tank III: ExecutionA. Testing and Installation: shall be tested and installed according to the XerxesInstallation Manual and Operating Guidelines for Single-WallFiberglass Underground Wastewater Tanks in effect at time ofeach Prior to installation, a tank-tightness test consisting of a 5psi air pressure/soap test shall be performed on all 4, 6, 8 and10 ft.

8 Diameter Tanks per the tank testing procedure outlined inXerxes current Installation Manual and Operating IV: WarrantyWarranty shall be manufacturer s current standard limited Corporation ( Xerxes ) warrants to ( Owner ) that ourunderground Septic Tanks , if installed, used and maintained in theUnited States in accordance with Xerxes published specifications,installation instructions and operating guidelines, all applicablelaws and regulations, and the limited Septic applications definedherein, will be free from material defects in materials andworkmanship for a period of one (1) year from date of originaldelivery by Xerxes. Septic applications for purposes of thiswarranty are limited to the collection and storage of human solidor liquid organic sewage at ambient temperatures.

9 Xerxes warrants to Owner that all Xerxes manufactured septictank accessories, if installed, used and maintained in the UnitedStates in accordance with Xerxes published specifications,installation instructions and operating guidelines, and allapplicable laws and regulations, will be free from material defectsin materials and workmanship for a period of one (1) year followingthe date of original delivery by any tank is to be removed from an installation, moved toOwner s new location and is intended for active service at the newlocation, the tank must be recertified by Xerxes in order tomaintain the warranty as originally extended. The foregoingwarranty does not extend to Tanks damaged due to acts of God,war, terrorism, or tank failures caused, in whole or in part, bymisuse, improper installation, storage, servicing, maintenance, oroperation in excess of their rated capacity, contrary to theirrecommended use, or contrary to the Septic applications definedabove, whether intentional or otherwise, or any other cause ordamage of any kind not the fault of Xerxes.

10 Xerxes only warrantsrepairs or alterations performed by Xerxes or its authorizedcontractor. Xerxes does not warrant any product, components orparts manufactured by others. THIS WARRANTY IS NULL ANDVOID IF A TANK HAS BEEN USED FOR PRODUCTSCONTAINING A HAZARDOUS SUBSTANCE AS DEFINED BYTHE COMPREHENSIVE ENVIRONMENTAL RESPONSE,COMPENSATION AND LIABILITY ACT OF 1980 (CERCLA OR SUPERFUND ) WHICH DESIGNATES CERTAIN CHEMICALSAS HAZARDOUS SUBSTANCES. SEE 42 UNITED STATESCODE, SECTION 9601 (14). Owner s sole and exclusive remedy for breach of warrantyis limited at Xerxes option to: (a) repair of the defective tank oraccessory, (b) delivery of a replacement tank or accessory, to thepoint of original delivery, or (c) refund of the original purchaseprice.