Example: confidence

Filter regulators MS-LFR, MS series

Filter regulators MS-LFR, MS seriesq/wFesto core product rangeCovers 80% of your automation tasksWorldwide:Always in stockSuperb:Festo quality at an attractive priceEasy:Reduces procurement and storing complexityqGenerally ready for shipping ex works in 24 hoursHeld in stock in 13 service centres worldwideMore than 2200 productwGenerally ready for shipping ex works in 5 daysAssembled for you in 4 service centres worldwideUp to 6 x 1012 variants per product seriesLook for the star!Subject to change 2019/062 Internet: series service unit componentsKey featuresMS series service unit componentsSolutions for every applicationFreely combinable function modulesWith its large product range, highlyfunctional components and a widechoice of services, the MS series fromFesto offers a complete concept forcompressed air preparation.

Soft-start/quick exhaust valves MS-SV Technical data Internet: ms-sv For building up pressure gradually and reducing pressure quickly and safely in pneumatic piping systems. Up to category 1, PL c. 6 – – ½ – ¼, y, ½, ¾ ¼, y, ½, ¾ 9 – – ¾, 1 ¾, 1 ½, ¾, 1, 1¼, 1½ ½, ¾, 1, 1¼, 1½ Up to category 3, PL d.

Tags:

  Pressure, Reducing, Valves, Pressure reducing

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Advertisement

Transcription of Filter regulators MS-LFR, MS series

1 Filter regulators MS-LFR, MS seriesq/wFesto core product rangeCovers 80% of your automation tasksWorldwide:Always in stockSuperb:Festo quality at an attractive priceEasy:Reduces procurement and storing complexityqGenerally ready for shipping ex works in 24 hoursHeld in stock in 13 service centres worldwideMore than 2200 productwGenerally ready for shipping ex works in 5 daysAssembled for you in 4 service centres worldwideUp to 6 x 1012 variants per product seriesLook for the star!Subject to change 2019/062 Internet: series service unit componentsKey featuresMS series service unit componentsSolutions for every applicationFreely combinable function modulesWith its large product range, highlyfunctional components and a widechoice of services, the MS series fromFesto offers a complete concept forcompressed air preparation.

2 Suitablefor simple standard applications aswell as application-specific solutionsto the highest quality as individual components,pre-assembled combinations ex-stock,application-specific combinations orcomplete turnkey solutions. The fivesizes in the MS series achievemaximum flow rates with minimumspace regulators , on/off and soft-start valves with safety function, Filter , pressure and flow sensors, dryers,sensors and lubricators. All theseallow a suitable solution to be as sembled for every task. Their modularstructure means that the componentsare freely combinable. A simpleconnection system saves time whenreplacing individual modules withoutdismantling the entire 's more, many of the componentsare certified to UL and models and configuratorEngineering toolsConvenient aids for planning and se lecting application-specific individualdevices and combinations.

3 Theproduct configurator lets you config ure customised solutions quickly andtransfer the order data with no tool for choosing the rightservice unit without oversizing, andwith the right air quality class: tungseinheitIntegrated sensorsSafety functionsEnergy savingsPressure and flow sensorsSoft-start/quick exhaust valvesMS6-SV/MS9-SVService units MSE6 Intelligent mix of sizes Maximum machine availabilitythrough controlled processes Reliable compressed airpreparation and supply for systems Integrable or stand-alone Easy to connect with M8/M12 plug Fast and reliable exhausting ofsystems up to Performance Level e.

4 Certified to EN ISO 13849-1 Integrated soft-start function Fully automatic monitoring andregulation of compressed air supply Automatic shut-off of thecompressed air in stand-by mode Detection and notification ofleakages Condition monitoring of relevantprocess data Optimum flow rate with up to 18%smaller size Excellent energy efficiency Cost-optimised combinations save up to 30%!Size differencesSizeMS2MS4MS6MS9MS12 Grid dimension[mm]25406290124 Port sizesM5, QS-6Gx, G , GyG , Gy, G , G G , G , G1, G1 ,G1 G1, G1 , G1 , G2 Standard nominal flow rateqnN1)[l/min]3501800650020000220001)U sing pressure regulator MS-LR as an example2019/06 Subject to change3 Internet.

5 series service unit componentsKey featuresNoteInformationThe next few pages provide a briefoverview of the complete productrange for the MS series service can find detailed information andall of the technical data in thedocumentation for the correspondingservice unit such as connection platesor mounting brackets can be orderedeither via the configurator of a service unitThe order of the individual compon ents within a service unit is relevantfor safety and functionality. It is notpossible to assemble the service unitcomponents in any order in the flowdirection. There are restrictions configurator for service unit MSBis a reliable and convenient way ofarranging individual service unitcomponents.

6 This ensures that theapplicable rules are complied with. Asa result, you get a completelyassembled combination with UL orATEX certification if you need arranging a combination ofindividually configured and orderedservice unit components, the pointson the right must be adhered to underall circumstances. regulators MS-LFR/LR/LRP/LRE areonly permissible in the flow direc tion with the same or decreasingpressure regulation range Filters MS-LFR/LF/LFM/LFX are onlypermissible in the flow directionwith an increasing grade offiltration Lubricators MS-LOE are not permit ted in the flow direction upstreamof a Filter MS-LFR/LFM/LF/LFX.

7 Waterseparator MS-LWS or membrane airdryer MS-LDM1 A micro Filter MS-LFM must beinstalled upstream of an activatedcarbon Filter MS-LFX or membraneair dryer MS-LDM1 in the flowdirection A flow sensor SFAM cannot beinstalled directly downstream of aregulator MS-LFR/LR; a branchingmodule MS-FRM must bepositioned between them A soft-start/quick exhaust valveMS-SV must be the last service unitcomponent in the flow directionTotal product range for MS series service unit componentsTypeDescriptionSizePneumatic connectionPush-inconnectorFemale threadConnection plate with threadMGNPTGNPTC ombinationsService units MSB-FRCT echnical data Internet: msbCombinations of Filter regulatorand lubricator4 x, 6 , y, Service units MSBT echnical data Internet.

8 Msb7 combinations, predefined4 6 Combinations freely configurable4 x, x, , yx, , y6 , y, , y, , , y, , 9 , 1 , 1 , , 1, 1 , 1 , , 1, 1 , 1 Service units MSE6 Technical data Internet: mse6 Combinations with fieldbus con nection for measuring pressure ,flow rate and consumption6 Subject to change 2019/064 Internet: series service unit componentsKey featuresTotal product range for MS series service unit componentsTypeDescriptionSizePneumatic connectionPush-inconnectorFemale threadConnection plate with threadMGNPTGNPTI ndividual devicesFilter regulators MS-LFRT echnical data Internet: ms-lfrFilter and pressure regulator in asingle device,grade of filtration 5 or 40 m2QS-6M5 4 x, x, , yx, , y6 , y, , y, , , y, , 9 , 1 , 1 , , 1, 1 , 1 , , 1, 1 , 1 12 1, 1 , 1 , 2 Filters MS-LFTechnical data Internet.

9 Ms-lfGrade of filtration 5 or 40 m4 x, x, , yx, , y6 , y, , y, , , y, , 9 , 1 , 1 , , 1, 1 , 1 , , 1, 1 , 1 12 1, 1 , 1 , 2 Fine and micro filters MS-LFMT echnical data Internet: ms-lfmGrade of filtration or 1 m4 x, x, , yx, , y6 , y, , y, , , y, , 9 , 1 , 1 , , 1, 1 , 1 , , 1, 1 , 1 12 1, 1 , 1 , 2 Activated carbon filters MS-LFXT echnical data Internet: ms-lfxFor removing liquid and gaseousoil particles4 x, x, , yx, , y6 , y, , y, , , y, , 9 , 1 , 1 , , 1, 1 , 1 , , 1, 1 , 1 12 1, 1 , 1 , 2 Water separators MS-LWST echnical data Internet: ms-lwsRemove condensed water fromcompressed air, maintenance-free6 , y, , y, , , y, , 9 , 1 , 1 , , 1, 1 , 1 , , 1, 1 , 1 12 1, 1 , 1 , 2 2019/06 Subject to change5 Internet.

10 series service unit componentsKey featuresTotal product range for MS series service unit componentsTypeDescriptionSizePneumatic connectionPush-inconnectorFemale threadConnection plate with threadMGNPTGNPTI ndividual devicesPressure regulators MS-LRTechnical data Internet: ms-lrFor setting the required operatingpressure,4 pressure regulation ranges2QS-6M5 4 x, x, , yx, , y6 , y, , y, , , y, , 9 , 1 , 1 , , 1, 1 , 1 , , 1, 1 , 1 12 1, 1 , 1 , 2 pressure regulators MS-LRBT echnical data Internet: ms-lrbFor creating a regulator manifoldwith independent pressure regula tion ranges.