Example: dental hygienist

Fire Rated Wall Assemblies Other CertainTeed Products for ...

33 Other CertainTeed Products for Commercial ConstructionCertainTeed Metal Building Insulation 202-96 InsulSafe 4 Fiber Glass Blowing InsulationOPTIMA Loose Fill Fiber Glass InsulationECOPHON Commercial Ceiling SystemsToughGard Duct Board with Enhanced SurfaceA flexible blanket of fiber glass insulation,furnished in rolls, designed to be faced onone side with a suitable vapor retarder byindependent metal building insulation ADDITIONAL INFORMATION: PUB. NO. 30-27-003 High quality loose-fill insulation appliedusing recommended pneumatic blowingmachines. Designed for installation in openblow or closed cavities covered with net-ting or IsoMesh ADDITIONAL INFORMATION: PUB. NO. 30-24-231 High quality unbonded non-settling whitevirgin glass fiber designed for pneumaticinstallation in closed cavities covered withnon-woven OPTIMA fabric or ADDITIONAL INFORMATION: PUB.

2” x 4" wood studs on 16" centers 31/ 2” Certainteed fiber glass insulation Rating: 2 hour non-bearing (U 411 or U 419) Double layer 5/ 8” Type X gypsum board 35/ 8” steel studs on 24" centers 31/ 2” Certainteed fiber glass insulation Rating: 2 hour non-bearing (U 436) Chase wall: Double layer 5/ 8” Type X gypsum board 15/

Tags:

  Product, Other, Walls, Woods, Assemblies, Dust, Certainteed, Wood dust, Wall assemblies other certainteed products for

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of Fire Rated Wall Assemblies Other CertainTeed Products for ...

1 33 Other CertainTeed Products for Commercial ConstructionCertainTeed Metal Building Insulation 202-96 InsulSafe 4 Fiber Glass Blowing InsulationOPTIMA Loose Fill Fiber Glass InsulationECOPHON Commercial Ceiling SystemsToughGard Duct Board with Enhanced SurfaceA flexible blanket of fiber glass insulation,furnished in rolls, designed to be faced onone side with a suitable vapor retarder byindependent metal building insulation ADDITIONAL INFORMATION: PUB. NO. 30-27-003 High quality loose-fill insulation appliedusing recommended pneumatic blowingmachines. Designed for installation in openblow or closed cavities covered with net-ting or IsoMesh ADDITIONAL INFORMATION: PUB. NO. 30-24-231 High quality unbonded non-settling whitevirgin glass fiber designed for pneumaticinstallation in closed cavities covered withnon-woven OPTIMA fabric or ADDITIONAL INFORMATION: PUB.

2 NO. 30-24-216 High quality resin bonded glass woolceiling tiles, wall panels, and baffles withsmooth, white washable surfaces, in avariety of edge details. The systemcombines acoustical performance and highaesthetic values with integrated lighting ina fully demountable concealed grid system. FOR ADDITIONAL INFORMATION: CALL ECOPHON AT 1-877-258-7845 E-MAIL: WEBSITE: boards of resin bonded glass fiberswith a reinforced foil laminate air barrier/vapor retarder. ToughGard Duct Board hasa tough, durable, fire-resistant black com-posite air stream surface. Used to fabricateair ducts for heating, ventilating and airconditioning systems. (Pictured above:ToughGard duct board.)FOR ADDITIONAL INFORMATION: PUB.

3 NO. 30-34-006 Ultra*Duct GOLD Duct Board with Enhanced SurfaceUltra*Duct GOLD Duct Board is a rigidboard designed for fabrication into supplyand return air HVAC duct work. Composedof resin bonded glass fibers with a reinforced foil laminate air barrier/vaporretarder facing applied to the outside surface and a fiber glass textile mat bonded to the airstream ADDITIONAL INFORMATION: PUB. NO. 30-34-011 Rating: 2 hour non-bearing (U 419)Rating: 2 hour non-bearing (U 419)Rating: 2 hour non-bearing (U 419)Rating: 2 hour non-bearing (U 419)Rating: 2 hour non-bearing (U 419)Double layer 1/2 Type X gypsum board21/2 steel studs on 24" centers21/2 CertainTeed fiber glass insulationRating: 2 hour non-bearing (U 411)Rating: 2 hour non-bearing (U 411)Rating: 2 hour non-bearing (U 411)Rating: 2 hour non-bearing (U 411)Rating: 2 hour non-bearing (U 411)Double layer 5/8 Type X gypsum boardMin.

4 21/2 steel studs on 24" centers21/2 CertainTeed fiber glass insulationRating: 1 hour non-bearing (U 419)Rating: 1 hour non-bearing (U 419)Rating: 1 hour non-bearing (U 419)Rating: 1 hour non-bearing (U 419)Rating: 1 hour non-bearing (U 419)Single layer 5/8 Type X gypsum boardMin. 31/2 steel studs on 24" centers31/2 CertainTeed fiber glass insulationRating: 2 hour non-bearing (U 419)Rating: 2 hour non-bearing (U 419)Rating: 2 hour non-bearing (U 419)Rating: 2 hour non-bearing (U 419)Rating: 2 hour non-bearing (U 419)Double layer 1/2 Type X gypsum board35/8 steel studs on 24" centers31/2 CertainTeed fiber glass insulationRating: 1 hour non-bearing (U 465 or U 419)Rating: 1 hour non-bearing (U 465 or U 419)Rating: 1 hour non-bearing (U 465 or U 419)Rating: 1 hour non-bearing (U 465 or U 419)Rating: 1 hour non-bearing (U 465 or U 419)Single layer 5/8 Type X gypsum board35/8 steel studs on 24" centers31/2 CertainTeed fiber glass insulationRating.

5 1 hour non-bearing (U 465)Rating: 1 hour non-bearing (U 465)Rating: 1 hour non-bearing (U 465)Rating: 1 hour non-bearing (U 465)Rating: 1 hour non-bearing (U 465)Single layer 5/8 Type X gypsum board35/8 steel studs on 24" centers31/2 CertainTeed fiber glass insulationRating: 1 hour non-bearing (U 419)Rating: 1 hour non-bearing (U 419)Rating: 1 hour non-bearing (U 419)Rating: 1 hour non-bearing (U 419)Rating: 1 hour non-bearing (U 419)Single layer 5/8 Type X gypsum boardMin. 31/2 steel studs on 24" centers31/2 CertainTeed fiber glass insulationRating: 1 hour non-bearing (U 465 or U 419)Rating: 1 hour non-bearing (U 465 or U 419)Rating: 1 hour non-bearing (U 465 or U 419)Rating: 1 hour non-bearing (U 465 or U 419)Rating: 1 hour non-bearing (U 465 or U 419)Single layer 5/8 Type X gypsum board on each side6 steel studs on 24" centers61/4 CertainTeed fiber glass insulationRating: 2 hour non-bearing (U 419)Rating: 2 hour non-bearing (U 419)Rating: 2 hour non-bearing (U 419)Rating: 2 hour non-bearing (U 419)Rating.

6 2 hour non-bearing (U 419)Double layer 5/8 Type X gypsum board on each side6 steel studs on 24" centers61/4 CertainTeed fiber glass insulationRating: Rating: Rating: Rating: Rating: 33333/////44444 hour bearing (U 317) hour bearing (U 317) hour bearing (U 317) hour bearing (U 317) hour bearing (U 317)Single layer 1/2 Type X gypsum board on each side2" x 4" wood studs on 16" centers31/2 CertainTeed fiber glass insulationRating: 1 hour bearing (U 341)Single layer 5/8 Type X gypsum board on each side2" x 4" double wood studs on 24" centers2 layers 31/2 CertainTeed fiber glass insulationRating: 1 hour bearing (U 305)Single layer 5/8 Type X gypsum board on each side2 x 4" wood studs on 16" centers31/2 CertainTeed fiber glass insulationRating: 2 hour non-bearing (U 411 or U 419)Rating: 2 hour non-bearing (U 411 or U 419)Rating: 2 hour non-bearing (U 411 or U 419)Rating: 2 hour non-bearing (U 411 or U 419)Rating: 2 hour non-bearing (U 411 or U 419)Double layer 5/8 Type X gypsum board35/8 steel studs on 24" centers31/2 CertainTeed fiber glass insulationRating: 2 hour non-bearing (U 436)Rating: 2 hour non-bearing (U 436)Rating: 2 hour non-bearing (U 436)Rating: 2 hour non-bearing (U 436)Rating: 2 hour non-bearing (U 436)Chase wall.

7 Double layer 5/8 Type X gypsum board15/8 steel studs on 24" centersCertainteed fiber glass insulation to fill cavityRating: 1 hour non-bearing (U 420)Rating: 1 hour non-bearing (U 420)Rating: 1 hour non-bearing (U 420)Rating: 1 hour non-bearing (U 420)Rating: 1 hour non-bearing (U 420)Chase wall: Single layer 5/8 Type X gypsum board15/8 steel studs on 24" centers31/2 CertainTeed fiber glass insulationRating: 2 hour non-bearing (U 420)Rating: 2 hour non-bearing (U 420)Rating: 2 hour non-bearing (U 420)Rating: 2 hour non-bearing (U 420)Rating: 2 hour non-bearing (U 420)Chase wall: Double layer 5/8 Type X gypsum board15/8 steel studs on 24" centers21/2 CertainTeed fiber glass insulationRating: 2 hour non-bearing (U 497)Rating: 2 hour non-bearing (U 497)Rating: 2 hour non-bearing (U 497)Rating: 2 hour non-bearing (U 497)Rating: 2 hour non-bearing (U 497)Shaft wall: Single layer 1" Type FSW gypsum boardone side, Double layer 1/2 Type FSW-G gypsum boardother side21/2 steel IIIII studs on 24" centers11/2 CertainTeed Partition insulationRating: 2 hour non-bearing (U 498)Rating: 2 hour non-bearing (U 498)Rating: 2 hour non-bearing (U 498)Rating: 2 hour non-bearing (U 498)Rating: 2 hour non-bearing (U 498)Shaft wall.

8 Double layer (1" Type X + 1/2 Type FSW)gypsum board on one side, Single layer 1/2 Type FSW-G gypsum board on Other side21/2 steel IIIII studs on 24" centers11/2 CertainTeed Partition insulationRating: 1 hour non-bearing (U 499)Rating: 1 hour non-bearing (U 499)Rating: 1 hour non-bearing (U 499)Rating: 1 hour non-bearing (U 499)Rating: 1 hour non-bearing (U 499)Shaft wall: Single layer 1" Type FSW gypsum board onone side, single layer 5/8 Type FSW gypsum board onother side21/2 steel IIIII studs on 24" centers11/2 CertainTeed Partition insulationNOTE:Drawings for illustration purposes only. Refer toUnderwriters Laboratories Fire Resistance Directoryfor assembly details and Other Rated Wall Assemblies


Related search queries