E1WF eex d iic & EEx e II Brass Gland472AA SeriesFlameproof GlandsFeatures & Benefi tsRef: E1WF/05/08> For steel wire armoured cableApplication> Brass indoor and outdoor cable gland for use in hazardous areas> Suitable for circular, galvanised steel wire armour cables with extruded polymeric bedding and oversheath> Achieves IP66 seal onto cable and to enclosure with suitable sealing washer or thread sealant> Three part armour lock provides mechanical cable retention and electrical continuity> Inner seal grips cable bedding and provides additional ingress protection> Suitable for most climatic conditions - weatherproof and waterproof > Nickel plated versions also available> Matching accessory kits availablePrysmian Cables & Systems Limited, Components Unit, Oak Road, Wrexham Industrial Estate, Wrexham, LL13 9PH.

E1WF EEx d IIC & EEx e II Brass Gland 472AA Series Flameproof Glands Features & Benefi ts Ref: E1WF/05/08 Application > For steel wire armoured cable > Brass indoor and outdoor cable gland for use in hazardous areas

Tags:

  Eex d iic

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of Flameproof Glands E1WF EEx d IIC & EEx e II Brass …

1 E1WF eex d iic & EEx e II Brass Gland472AA SeriesFlameproof GlandsFeatures & Benefi tsRef: E1WF/05/08> For steel wire armoured cableApplication> Brass indoor and outdoor cable gland for use in hazardous areas> Suitable for circular, galvanised steel wire armour cables with extruded polymeric bedding and oversheath> Achieves IP66 seal onto cable and to enclosure with suitable sealing washer or thread sealant> Three part armour lock provides mechanical cable retention and electrical continuity> Inner seal grips cable bedding and provides additional ingress protection> Suitable for most climatic conditions - weatherproof and waterproof > Nickel plated versions also available> Matching accessory kits availablePrysmian Cables & Systems Limited, Components Unit, Oak Road, Wrexham Industrial Estate, Wrexham, LL13 9PH.

2 UKCommercial Enquiries, Tel +44 (0) 845 767 8345, Fax: +44 (0) 23 8029 Data> Certi ed 2GD, EEx e & EEx d C under ATEX directive 94/9/EC> Certi cate number Sira02 ATEX3092X> Service temperature range 60 C to +90 C> May be used in: - Zones 0, 1 & 2 with EEx ia A, B & C equipment - Zones 1 & 2 with EEx ib A, B & C equipment - Zones 1 & 2 with EEx e equipment - Zones 1 & 2 with EEx p equipment - Zones 2 with EEx nA equipment - Zone 21 & 22 with EEx tD equipment> Where the cable is effectively lled, may also be used in: - Zones 1 & 2 with eex d iic equipment not containing a source of ignition & with a volume less than 2000cm - Zones 1 & 2 with EEx d IIA & EEx d IIB equipment not containing a source of ignition & with any volume - Zone 1 with EEx d IIA & EEx d IIB equipment containing a source of ignition & with a volume less than 2000cm - Zone 2 with EEx d IIA & EEX d IIB equipment containing a source of ignition & with any volume - Zone 2 with EEX nR II equipment> Certifi ed II 2GD.

3 EEx e II d IIC under ATEX directive 94/9/EC> IEECx Sir > Certifi cate number Sira02 ATEX3092X> Applied Standards: - IEC 60079-0: 2004 - IEC 60079-1: 2007-04 - IEC 60079-7: 2006-07 - IEC 61241-0: 2004 - IEC 61241-1: 2004 - EN 60079-0: 2006 - EN 60079-1: 2007 - EN 60079-7: 2007 - EN 61241-0: 2006 - EN 61241-1: 2004> Service temperature range -60oC to +90oC> May be used in: - Zones 0, 1 & 2 with EEx ia IIA, B & C equipment - Zones 1 & 2 with EEx ib IIA, B & C equipment - Zones 1 & 2 with EEx e II equioment - Zones 2 with EEx nA II equipment - Zone 21 & 22 with Ex tD A21 IP66> Where the cable is effectively fi lled, may also be used in.

4 - Zones 1 & 2 with eex d iic equipment not containing a source of ignition & with a volume less than 2000cm3 - Zones 1 & 2 with EEx d IIA & EEx d IIB equipment not containing a source of ignition & with any volume - Zone 1 with EEx d IIA & EEx d IIB equipment containing a source of ignition & with a volume less than 2000cm3 - Zone 2 with EEx d IIA & EEx d IIB equipment containing a source of ignition & with any volume - Zone 2 with EEx nR II equipment> Inner PCP seal grips cable bedding and provides additional ingress protection06/11 Gland DetailsRef: E1WF/05/08E1WF eex d iic & EEx e II Brass Gland 472AA SeriesPrysmian Cables & Systems Limited, Components Unit, Oak Road, Wrexham Industrial Estate, Wrexham, LL13 9PH, UKCommercial Enquiries, Tel +44 (0) 845 767 8345, Fax: +44 (0) 23 8029 Gland References & Thread SizesCable Dimensions mmGland Dimensions mmBasicSizeMetricNPTI nner Sheath Dia.

5 A OverallDia. B BraidWireDia. C D Hexagon SizeDesign *Design SizeA/C E A/F F MinMaxMinMax16472AA51M16 - 14 - 14 / - 14 / - 14 / - 14 / - 14 / - 11 / - 11 / - 11 / - 11 / - 11 / - 11 / - 11 / - 11 / - 11 - 8 - 8 - 8 2472NP473 - 8 * Pitch threads are supplied 15mm long, 2mm pitch threads are supplied 20mm long06/11