12-560. FLOODED BATTERY RACKS . SELECTION GUIDE FOR RDB & RDC SERIES, STANDBY POwER RACKS . Non- seismic and Earthquake Protected (EP1, EP2), IEEE-693. 1-Tier, 2-Tier, 3-Tier, 2-Step D, DJ, DJU, J, K, and L/XT Cell Types Heavy Gauge Steel Construction Shown: L-Series, 2-tier, EP, painted rail, back-to-back installation, with standard 2-rail and optional third (center) support rail. 12-560/0712/CD RDB & RDC rack FEATURES AND BENEFITS. C&D Technologies RDB and RDC RACKS offer a variety of RDB 693 RACKS are qualified to IEEE 693-2005. C&D strives quality and value-added features.

12-560 FLOODED BATTERY RACKS SELECTION GUIDE FOR RDB & RDC SERIES, STANDBY POwER RACKS • Non-seismic and Earthquake Protected (EP1, EP2), IEEE-693

Tags:

  Seismic, Rack, Battery, Flooded, Flooded battery racks

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of FLOODED BATTERY RACKS - C&D Technologies

1 12-560. FLOODED BATTERY RACKS . SELECTION GUIDE FOR RDB & RDC SERIES, STANDBY POwER RACKS . Non- seismic and Earthquake Protected (EP1, EP2), IEEE-693. 1-Tier, 2-Tier, 3-Tier, 2-Step D, DJ, DJU, J, K, and L/XT Cell Types Heavy Gauge Steel Construction Shown: L-Series, 2-tier, EP, painted rail, back-to-back installation, with standard 2-rail and optional third (center) support rail. 12-560/0712/CD RDB & RDC rack FEATURES AND BENEFITS. C&D Technologies RDB and RDC RACKS offer a variety of RDB 693 RACKS are qualified to IEEE 693-2005. C&D strives quality and value-added features.

2 Most notably, both rack to be the leader in supplying the best quality RACKS to support series take advantage of a common-frame design among its highly regarded FLOODED product line. The RDB and RDC. the Standard, EP1, and EP2 series for all but the RDC 3 Tier RACKS offer a range of quality features while maintaining a EP2 rack . This allows the RACKS to be field upgradeable by competitive price structure. simply installing additional bracing, while not having to remove any batteries! Additionally, the RACKS use a C-Channel frame cross-section that is more robust than competitive designs.

3 The RDB EP RACKS are qualified to meet UBC 1994 Section 1630 seismic loading conditions. The RDC EP RACKS are qualified to IBC 2009 Section 1613. Other features, such as built-in grounding provisions, are listed below. STANDARD rack FEATURES: rack seismic OPTIONS: 1-Tier, 2-Tier, 3-Tier, and 2-Step styles in Standard and RDB EP RACKS Qualified to Meet Maximum UBC 1994. seismic Requirements, Section 1630, for Essential and Custom Lengths Above Grade, Zones 1-4. RDB models can be upgraded Strut Rails with Flame Retardant Polyethylene Rail to UBC 1997. Contact C&D for information.

4 Covers, Provide Electrical Isolation RDC EP RACKS are Qualified to Meet Maximum IBC 2009. Rugged C-Channel Frame Design seismic Requirements, Section 1613, for Essential, Top of Building, Site Class D, up to SS=300%. Available For Welded Steel Frames with an Acid Resistant, L/XT Cells only. Electrostatically Applied Epoxy Powder Coat, Telephone Gray RDB 693 RACKS are Qualified to Meet Maximum IEEE. 693 2005 requirements are available for some models. Electrical Grounding Provisions Built into Base of Each Frame OPTIONAL rack FEATURES: Flame Retardant PVC BATTERY Spacers Included with EP.

5 RACKS (L- RACKS Only) Spacers for all Other Sizes are Open-Cell Styrene (Styrofoam). Optional flame-retardant Third Center Support Rail (L-Series Only). foam spacers also available. Field Upgradeable from STD to EP1 to EP2. Rails Accommodate Clip Nuts for Bolt-on Accessories Simplified Installation with Accessible Anchor Bolt Locations RACKS are Shipped Unassembled rack DETAILS. TwO-TIER TwO-TIER. STANDARD rack EP rack . 12-560/0712/CD 2 rack DETAILS AND DImENSIONS. 1-Tier 2-Tier 3-Tier 2-Step BATTERY Type Series Configuration DF in. (mm) HF in. (mm) HB in. (mm). RDB0700 1-Tier (381) (342) (468).

6 D. RDB0701 2-Tier (381) (940) (1065). RDB0702 3-Tier (410) (1537) (1662). RDB0703 2-Step (711) (749) (875). RDB0800 1-Tier (462) (424) (571). DJ,J, RDB0801. RDB0802. 2-Tier 3-Tier (513). (516). (1165). (1907). (1313). (2054). DJU RDB0803. RDB0800. RDB0801. 2-Step 1-Tier 2-Tier (943). (462). (513). (911). (424). (1165). (1059). (659). (1400). K RDB0802. RDB0803. 3-Tier 2-Step (511). (943). (1906). (911). (2141). (1146). L, RDC0900 1-Tier (611) (483) (770). RDC0901 2-Tier (611) (1372) (1672). xTL. RDC0902 3-Tier (637) (2121) (2408). RDC0903 2-Step (1137) (1041) (1329).

7 RDC0900 1-Tier (611) (483) (777). xTH RDC0901. RDC0902. RDC0903. 2-Tier 3-Tier 2-Step (611). (637). (1137). (1372). (2121). (1041). (1679). (2415). (1336). NOTES: 1. Consult engineering assembly drawings for more detailed dimensions and 5. Multiple rack configurations: Back-to-back RACKS specific rack weights. may be bolted together. 5 in. (127 mm) minimum separation required between end-to-end EP rack 2. rack depth does not include thickness of cross bracing and hardware. installations. End-to-end Standard rack installations 3. The 800 series RDB RACKS will support either DJ, DJU, J or K cell types.

8 Need no minimum separation. Spacer blocks are included to position cell restraint rails for the J-series, EP RACKS . 4. Typical clearance: 2 in. (51 mm) minimum around rack perimeter, 36 in. (914 mm) typical isle clearance. 12-560/0712/CD 3 RDB SERIES EARTHQUAKE PROTECTED (EP) RACKS . C&D offers a complete line of steel standby BATTERY RACKS for use in locations that are subject to seismic disturbances. Two Earthquake Protected BATTERY storage rack categories (EP1 and EP2) are offered to suit a variety of seismic loading conditions. These designs have been qualified to the 1994 Uniform Building Code (UBC), Chapter 16, Division III, Earthquake Design , Section 1630, Lateral Force on Elements of Structures, Nonstructural Components and Equipment Supported by Structures.

9 SELECTING THE RIGHT RDB rack EP CATEGORY: 1. Determine the UBC seismic zone corresponding with the exact geographic location of the installation site. See map below. 2. Determine if the installation is (a) essential or non-essential and (b) located above grade or located at or below grade. 3. Choose the C&D seismic RDB rack category from the chart below which is qualified for that location. seismic ZONE mAP OF THE UNITED STATES (REFERENCE 1994 UBC). C&D recommends that you consult your local or state building commission to verify the seismic zone factor and to check on local and special building requirements.

10 ZONE-0. ZONE-1. ZONE-2A. ZONE-2B. ZONE-3. ZONE-4. C&D BATTERY rack SELECTION BASED ON UBC seismic LOADS (G). UBC seismic Zone Non-essential, Non-essential, Essential Use C&D. at or below grade (g) above grade OR above grade (g) BATTERY rack Type: Essential at or below grade (g). ZONE-0 Standard ZONE-1 EP1. ZONE-2A (Qualified to g). ZONE-2B ZONE-3 EP2. ZONE-4 (Qualified to g). C&D recommends that you consult your local or state building commission to verify the seismic zone factor and to check on local and special building requirements. RDB RACKS can be upgraded to UBC 1997 essential at or below grade contact C&D.