Document No. 7013227M(Revision H) four CHANNEL CONTROLLERS ensidyne, LP1000 112th Circle N, Suite 100St. Petersburg, Florida 33716 USA(800) 451-9444 (727) 530-3602 Fax: (727) 539-0550web: e-mail: Push RESET to unlatch a LATCHED ALARM Push RESET to silence a local LO ALARM Push RESET for 5 seconds to enter CAL MODE (Push RESET again to exit CAL MODE) %VOLLOHIHI HIMETHANE9 %LELLOHIHI HIAMMONIA19 PPMLOHIHI PPMLOHIHI HIFAULTCH 1 FAULTCH 3 FAULTCH 4 FAULTCH 2 POWERDC PWRBACK UPAC PWRPRELIMINARYS ensidyne Document No. 7013227M (Rev H)3 SENSALERT four CHANNEL CONTROLLERDISCLAIMERSENSIDYNE, LP ASSUMES NO RESPONSIBILITY WHATSOEVER, TO ANY PARTY WHOSOEVER, FORANY PROPERTY DAMAGE, PERSONAL INJURY, OR DEATH RECEIVED BY OR RESULTING FROM, INWHOLE, OR IN PART, THE IMPROPER USE, INSTALLATION, OR STORAGE OF THIS PRODUCT BYTHE USER, PERSON, FIRM, ENTITY, CORPORATION OR PARTY NOT ADHERING TO THE INSTRUC-TIONS AND WARNINGS OR NOT ADHERING TO ALL FEDERAL, STATE, AND LOCAL ENVIRONMEN-TAL AND OCCUPATIONAL HEALTH AND SAFETY LAWS AND SELLER SHALL NOT BE LIABLE FOR DIRECT, INDIRECT, CONSEQUENTIAL, INCIDENTAL OROTHER DAMAGES RESULTING FROM THE SALE AND USE OF ANY GOODS AND SELLER S LIABIL-ITY HEREUNDER SHALL BE LIMITED TO REPAIR OR REPLACEMENT OF ANY GOODS FOUND DE-FECTIVE.

sensidyne document no. 7013227m (rev h) preliminary 3 sensalert four channel controller disclaimer sensidyne, lp assumes no responsibility whatsoever, to …

Tags:

  Controller, Four, Channel, Four channel controller

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of FOUR CHANNEL CONTROLLER - Sensidyne Gas …

1 Document No. 7013227M(Revision H) four CHANNEL CONTROLLERS ensidyne, LP1000 112th Circle N, Suite 100St. Petersburg, Florida 33716 USA(800) 451-9444 (727) 530-3602 Fax: (727) 539-0550web: e-mail: Push RESET to unlatch a LATCHED ALARM Push RESET to silence a local LO ALARM Push RESET for 5 seconds to enter CAL MODE (Push RESET again to exit CAL MODE) %VOLLOHIHI HIMETHANE9 %LELLOHIHI HIAMMONIA19 PPMLOHIHI PPMLOHIHI HIFAULTCH 1 FAULTCH 3 FAULTCH 4 FAULTCH 2 POWERDC PWRBACK UPAC PWRPRELIMINARYS ensidyne Document No. 7013227M (Rev H)3 SENSALERT four CHANNEL CONTROLLERDISCLAIMERSENSIDYNE, LP ASSUMES NO RESPONSIBILITY WHATSOEVER, TO ANY PARTY WHOSOEVER, FORANY PROPERTY DAMAGE, PERSONAL INJURY, OR DEATH RECEIVED BY OR RESULTING FROM, INWHOLE, OR IN PART, THE IMPROPER USE, INSTALLATION, OR STORAGE OF THIS PRODUCT BYTHE USER, PERSON, FIRM, ENTITY, CORPORATION OR PARTY NOT ADHERING TO THE INSTRUC-TIONS AND WARNINGS OR NOT ADHERING TO ALL FEDERAL, STATE, AND LOCAL ENVIRONMEN-TAL AND OCCUPATIONAL HEALTH AND SAFETY LAWS AND SELLER SHALL NOT BE LIABLE FOR DIRECT, INDIRECT, CONSEQUENTIAL, INCIDENTAL OROTHER DAMAGES RESULTING FROM THE SALE AND USE OF ANY GOODS AND SELLER S LIABIL-ITY HEREUNDER SHALL BE LIMITED TO REPAIR OR REPLACEMENT OF ANY GOODS FOUND DE-FECTIVE.

2 THIS WARRANTY IS IN LIEU OF ALL OTHER WARRANTIES, EXPRESSED OR IMPLIED, IN-CLUDING BUT NOT LIMITED TO THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESSFOR USE OR FOR A PARTICULAR PURPOSE WHICH ARE EXPRESSLY check to make certain you have received all of the items listed above. If you have any questions orneed assistance, contact your Sensidyne Representative, or call (800) 451-9444 or (727) 530-3602 The items listed below are shipped with the SensAlert four CHANNEL CONTROLLER : 4 20 mA CONTROLLER with built-in readout displays,housed in a NEMA 4X fiberglass enclosure. Operation and Service ManualPACKING LIST & NOTICESPROPRIETARY NOTICEThis manual was prepared by Sensidyne , LP exclusively for the owner of the SensAlert four CHANNEL CONTROLLER . The material within this manual isthe proprietary information of Sensidyne , LP and is to be used only to understand, operate, and service the instrument. By receiving this docu-ment, the recipient agrees that neither this document nor the information disclosed within nor any part shall be reproduced or transferred, physi-cally, electronically or in any form or used or disclosed to others for manufacturing or for any other purpose except as specifically authorized inwriting by Sensidyne , NOTICE 2002, 2008 Sensidyne , LP.

3 All rights reserved. Information contained in this document is protected by copyright. No part of this document maybe photocopied, reproduced, or translated to another program or system without prior written authorization from Sensidyne , NOTICES ensidyne, the Sensidyne logo, SensAlert, and the SensAlert logo are registered trademarks of Sensidyne , LP. SensAlarm is a trademark of Sensidyne ,LP. The trademarks and service marks of Sensidyne , LP are protected through use and registration in the United LICENSEThe software included with the SensAlert is the property of Sensidyne , LP and shall remain the property of Sensidyne , LP in perpetuity. The soft-ware is protected by and international copyright laws and is licensed for specific use with the SensAlert four CHANNEL CONTROLLER . The usermay NOT reverse-engineer, disassemble, decompile, or make any attempt to discover the source code of the software. The software may NOT betranslated, copied, merged or modified in any way.

4 The user may NOT sublicense, rent, or lease any portion of the software. The right to use thesoftware terminates automatically if any part of this license is four CHANNEL CONTROLLERS ensidyne Document No. 7013227M (Rev H)4 PREFACE Packing List & Notices ..3 WARNINGS .. 7 SECTION ONE: .. Housing .. PCB .. PCB .. Buttons .. Screens .. Screens .. Screens .. 12 SECTION TWO: & Wiring .. Designations .. Procedure .. Start-Up ..21 TABLE OFCONTENTSPRELIMINARYS ensidyne Document No. 7013227M (Rev H)5 SENSALERT four CHANNEL CONTROLLERSECTION THREE: Screen .. Alarm Settings (Menu #1) .. a Password .. Calibration Mode .. 26 SECTION four : CHANGING ALARM SETTINGS Changing Alarm Settings .. 28 SECTION FIVE: USING SET-UP & (Menu #3) .. a CHANNEL .. Calibration Delay .. the Password .. the RS-485 Address .. Alarm Latching .. Relay .. the Zero Point .. (Menu #4) .. 335, Check .. 33 SECTION SIX: MAINTENANCE & the Output .. the Power Supply.

5 The Display PCB .. the Bottom PCB .. 35 SECTION SIX: PARTS LIST CONTROLLER Parts .. 36 TABLE OFCONTENTSPRELIMINARYSENSALERT four CHANNEL CONTROLLERS ensidyne Document No. 7013227M (Rev H)6 LIST OFFIGURES & TABLESAPPENDICES Appendix A: Specifications General Specifications .. 37 Appendix D: Troubleshooting Guide Troubleshooting Guide .. 38 Appendix E: Returned Material Authorization Returned Material Authorization .. 39 Service Options .. 39 LIST OF FIGURESS ection One: PCB .. Menu System: Main Screens .. Menu System: Individual CHANNEL Screens .. 14 Section Two: Wiring: Bottom PCB .. the Mounting Feet .. Mounting .. Wiring Guide .. to a SensAlert Transmitter (with Intrinsic Safety Barrrier) .. to a SensAlert Transmitter (without Intrinsic Safety Barrrier) .. to a non-SensAlert Transmitter (without Intrinsic Safety Barrrier) .. 24 Section Three: a Password .. 27 Section Five: Using Set-Up & a Password .. 31 PRELIMINARYS ensidyne Document No.

6 7013227M (Rev H)7 SENSALERT four CHANNEL CONTROLLERREAD AND UNDERSTAND ALL WARNINGS BEFORE USERead and understand ALL warnings before using this product. Failure to read, understand, andcomply with ALL warnings could result in property damage, severe personal injury, or and understand ALL applicable Federal, State, and Local environmental health and safetylaws and regulations, including OSHA. Ensure complete compliance with ALL applicable lawsand regulations before and during use of this NO CIRCUMSTANCES should this product be used except by qualified, trained, techni-cally competent personnel and not until the warnings, Operation and Service Manual, labels,and other literature accompanying this product have been read and product should NOT be used in any way other than specified in this NOT remove, cover, or alter any label or tag on this product, its accessories, or NOT operate this product should it malfunction or require repair. Operation of a malfunc-tioning product, or a product requiring repair may result in serious personal injury or NOT attempt to repair or modify the instrument, except as specified in the Operation andService Manual.

7 Contact the Sensidyne Service Department to arrange for a Returned MaterialAuthorization (RMA).ONLY use genuine Sensidyne replacement parts when performing any maintenance proceduresprovided in this manual. Failure to do so may seriously impair instrument performance. Repair oralteration of the product beyond the scope of these maintenance instructions, or by anyone otherthan a certified Sensidyne serviceman, could cause the product to fail to perform as designed andpersons who rely on this product for their safety could sustain severe personal injury or (Earth) ground MUST terminate on each CONTROLLER s ground terminal to prevent an electricshock-hazard. A PCB board mounted ground lug is supplied with each of the alarm relays above their contact ratings may result in false alarms or relay NOTEThe output signal to the recorder, or other data gathering device, is always live. That is, the displayreading is transmitted directly through the recorder output to whatever peripheral device is attachedto the CONTROLLER .

8 Any recorder or other data gathering device should be turned off four CHANNEL CONTROLLERS ensidyne Document No. 7013227M (Rev H) OVERVIEWIMPORTANTYou must read this manual in its entirety to ensure properoperation of the manual provides specific information concerningthe installation, operation, and maintenance of theSensidyne SensAlert SensAlert CONTROLLER , when used with a Sensidyneexternal barrier (PN 7013263), is designed to oper-ate an intrinsically safe SensAlert transmitter in areasclassified Class I, Division 1, Groups A, B, C, D; Class II,Division 1, Groups E, F, ONEINTRODUCTIONThe Sensidyne SensAlert CONTROLLER is an integral partof the SensAlert Gas Monitoring System. The SensAlertController, housed in a NEMA 4X enclosure, providesseparate single pole double throw (SPDT) relays foreach alarm condition, plus one common relay for afault condition. It also serves as an interface when anevent needs to be relayed to a peripheral device, suchas a building fire alarm system.

9 The SensAlert Control-ler displays can display gas levels in either ppm, %vol,or %LEL, depending on the installed power supply for the CONTROLLER has been designedto operate at 90-265 VAC, with the capability of add-ing a 24 Vdc backup power of the features of SensAlert four CHANNEL Con-troller include: Auto-recognition of sensors Lo, Hi, HiHi, & Fault alarms User-selectable alarm levels Three relay contacts per sensor Lockout/tagout designed case RS-485 serial output 4-20 mA / 1-5 volt output Password protectionPRELIMINARYS ensidyne Document No. 7013227M (Rev H)9 SENSALERT four CHANNEL HousingThe NEMA 4X enclosure is made of high-grade, fiber-glass reinforced polyester resin matting. The enclosureprovides a weather-resistant and water-resistant barrierbetween the internal electronics and the ambient envi-ronment. The CONTROLLER cover is secured to the hous-ing with 2 quick release latches. Each latch has asmall circular knockout that allows the case to belocked or tagged to prevent unauthorized Reset switch is located on the bottom of the con-troller housing (refer to Figure ).

10 The switch can beused to (1) unlatch a latched alarm, (2) silence a localLo Alarm, or (3) enter Calibration Mode (whenpressed for 5 seconds).The Alarm Buzzer is located on the bottom of thecontroller housing, next to the cable glands. Thealarm buzzer is used for the Local PCBThe Display PCB contains the large, 3-digit LED dis-plays, the LCD displays, and the operator buttons thatcontrol the menu system. The Display PCB connectsto the Bottom PCB via a 20-pin flex cable. The com-ponents on the Display PCB are described as follows. Liquid Crystal DisplayThe Liquid Crystal Display (LCD) is a 16 character, 2-line display located behind the front cover of the con-troller enclosure (see Figure ). During normal op-eration, the display shows the gas name and gas con-centration (in ppm, %LEL, or %vol) for the sensor in-stalled at the transmitter. The display is also used forviewing and changing various features of thecontroller ( , alarm settings, passwords, etc.).During alarm and fault conditions, the display showsstatus messages on Line 2 describing the nature of thecondition ( , Lo Alarm, Missing Sensor, etc).