Fire Alarm Systems | FPA 5000 With Functional ModulesFPA 5000 With Functional Modules uModular configuration allowing for easy extensionuInterconnection of up to 32 Panel Controllers,Remote Keypads, and OPC serversuMultiple CAN loop connection with high-performance Ethernet backbone and redundancyuInstallation and auto-detection of functionalmodules by simply plugging them into the panel railuConnection to BIS Building Integration system viaOPC serverThanks to the modular configuration, the innovativeFPA 5000 Modular Fire Panel easily adapts to localcircumstances and regulations. Due to the differentfunctional Modules , country-specific characteristicsare accommodated in the connection just as quickly asthe respective alarm fire panel is available with two different housings: Housing for mounting directly on the wall Frame installation housings which are fitted to themounting frame and can be swiveledWith the aid of special mounting kits, the housings canbe mounted in mm (19") cabinets.

• for a connection with a voice alarm system Plena via RS232 IOS 0232 A RS232 Communication Module • with two RS232 interfaces • for a connection with a voice alarm system Plena , a printer or laptop ENO 0000 B Fire Service Interface Module • for the connection to fire service equipment according to DIN 14675 IOP 0008 A Input/Output Module

Tags:

  System, Panels, Lamar, Voice, Plena voice alarm system

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Advertisement

Transcription of FPA‑5000 With Functional Modules

1 Fire Alarm Systems | FPA 5000 With Functional ModulesFPA 5000 With Functional Modules uModular configuration allowing for easy extensionuInterconnection of up to 32 Panel Controllers,Remote Keypads, and OPC serversuMultiple CAN loop connection with high-performance Ethernet backbone and redundancyuInstallation and auto-detection of functionalmodules by simply plugging them into the panel railuConnection to BIS Building Integration system viaOPC serverThanks to the modular configuration, the innovativeFPA 5000 Modular Fire Panel easily adapts to localcircumstances and regulations. Due to the differentfunctional Modules , country-specific characteristicsare accommodated in the connection just as quickly asthe respective alarm fire panel is available with two different housings: Housing for mounting directly on the wall Frame installation housings which are fitted to themounting frame and can be swiveledWith the aid of special mounting kits, the housings canbe mounted in mm (19") cabinets.

2 All housingscan be extended with various additional housings forall conceivable FMR 5000 Remote Keypad offers the decentralizedoperation of a control panel or control panel to the external CAN and Ethernet interfaces,several Panel Controllers and Remote Keypads can beinterconnected. Using either a single loop structure ormultiple loop structures with Ethernet backbone, thenetwork can be adapted to nearly every Network1 Fire panel2 Remote KeypadAdditionally, the Ethernet interfaces allow theconnection to: Building Management system BIS, voice Alarm system Praesideo/PAVIRO, RemoteServices, FSM-2500/FSM-5000 Fire systems can be connected to the BoschUGM Universal Security system and thus, beintegrated into a large network entire fire detection system is configured via alaptop using the FSP-5000-RPS overviewNITUONITUO#0*895623741?PQRSTUVWX YZGHIJKIMNOABC DEFF i r eTestCity TieCity Tie FaultGround FaultBattery FaultPowerTroubleSignal SilenceBypassedSupervisoryNETZEINNETZSTR OMSt rungBATTERIE1St rungBATTERIE2St rungFAULTMAIN+-BAT1+-BAT2+-BAT1+- +-FAULTACFAULTAUX3+-AUX4+-AUX2+-AUX1+-AU X5+-AUX6+-BCM0000AL S N 0 3 0 0 AAU X 1+ -L S N 1a -b +AU X 2+ -L S N 2a -b +ZONE4St rungZONE3St rungZONE2St rungZONE1St rungCZM0004 AAUX1+ -OUT1+-IN1+-AUX2+ -OUT2+-IN2+-AUX3+ -OUT3+-IN3+-AUX4+ -OUT4+-IN4+-ANI0016AF2F1NC1NO1C1NC2NO2C2 FB1+-FB2+ -RELAIS2St rungRELAIS1St rungRMH0002 AOUT3 OUT2 OUT4 OUT6 OUT5 OUT7 GNDOUT8 GNDGNDGNDIN1IN3IN2IN4IN6IN5IN7 GNDIN8 GNDGNDGNDOUT1 IOP0008AC D H L M B E F G I A A ModulesBAddress Cards / Licencse KeysCPanel ControllerDDistributor, optionalEPanel Rail ShortFPower Supply Bracket (installed in Frame Installation Housingsex-works)GPower SupplyHHousing (in this case HCP 0006 A)

3 IPanel Rail LongLBatteriesMRemote KeypadFunctionsOperation / processing of messagesThe operation and the processing of all messages areeasy and intuitive thanks to the ergonomically-designed control panel with its TFT touch screenoffering a menu-driven handling and multi-colordisplay. To that end, there are permanently locatedkeys on the right, bottom, and upper edge of thedisplay as well as variably located virtual keys in thetouch-screen StructureDue to its modular structure, the FPA-5000 ModularFire Panel provides complete flexibility and thuscustomized solutions for any on the requirements, the followingselection can be made when planning:1. Housing type: Frame installation or wall-mount Selection of a basic housing Optional Extension Housings Optional Power Supply Housings Optional kits for installation in 48 cm (19'') racks2. Operating and Display Unit with Panel Controller Selection from the various language variants3.

4 Panel Rail Selection according to housing type and/ornumber of required Functional modules4. Functional Modules Selection based on planning and country-specificrequirements5. Power supply Batteries Additional power supply facilities Power Supply Brackets are preinstalled ex-worksfor Frame Installation Housings For Wall-mount Housings, Power Supply Bracketsare selected as needed6. Additional accessories Front Doors Printer with Frame Installation Housing Cable Sets for special applicationsModulesThe Functional Modules are autonomous, encapsulatedunits that can be inserted into any control panel slotusing plug-and-play technology. Thus, the powersupply and the data traffic to the control panel areindicated automatically without any additionalsettings. The module is automatically identified by thecontrol panel and functions in the default to external components is performed usingcompact connector/screw a replacement, only the connectors need to bereinserted.

5 Extensive rewiring is no longer | FPA 5000 With Functional ModulesModuleDescriptionBCM-0000-BBatter y Controller Module module that controls batteries and powersupplyANI 0016 AAnnunciator Module with 16 red and 16 yellow LEDs, freelyprogrammableLSN 0300 ALSN improved Module 300 mA for the connection of an LSN loop with upto 254 LSN improved elements or 127standard LSN elements, maximum linecurrent 300 mALSN 1500 ALSN improved Modul 1500 mA for the connection of an LSN loop with upto 254 LSN improved elements, maximumline current 1500 mA, or with up to 127standard LSN elements, maximum linecurrent 300 mAFPE-5000-UGMI nterface Module for the connection to a UGM 2020 SystemCZM 0004 A4 Zone Conventional Module for the connection of existing conventionalperipherals, with 4 monitoredconventional linesIOS 0020 A20 mA Communication Module with an S20 interface and an RS232interface for a connection with a voice alarm systemPlena via RS232 IOS 0232 ARS232 Communication Module with two RS232 interfaces for a connection with a voice alarm systemPlena , a printer or laptopENO 0000 BFire Service Interface Module for the connection to fire serviceequipment according to DIN 14675 IOP 0008 AInput/Output Module with 8 digital inputs and 8 open collectoroutputsRML 0008 ARelay Module with 8 relays for low voltage applicationsRMH 0002 ARelay Module with 2 relays for mains power (250 V) andwith feedback inputs (can also be used asan interface to extinguishing systems)

6 NZM 0002 ANotification Appliance Zone Module with 2 monitored primary linesNetworkingUp to 32 Panel Controllers, Remote Keypads and OPCserver can be interconnected within a on the application requirements, PanelControllers and Remote Keypads can be grouped,defined as network node or local node. Within a group,only panel conditions of the same group can bedisplayed. Regardless of the groups, network nodesallow for the display and handling of all panelconditions. Local nodes display the conditions of therelated networking via CAN and/or Ethernet interfaces,the following connection topologies are optional: Redundant loop via CAN1 and CAN2 (max. 32 nodes) Ethernet loop (max. 32 nodes) Multiple CAN loops with Ethernet backbone and up to32 nodesFor networking with optical fibers, you can use variousconverters. For detailed information on suitableconverter types and maximum line lengths, refer to theFPA-5000 Networking Guide (available for download).

7 Detection PointsThe Address Cards activate detection points. TheFPA-5000 governs up to 4096 detection element and input which is able to set off analarm requires a detection are considered as detection points if they areprogrammed accordingly in the FSP-5000-RPSP rogramming applies to all manual call points and automaticdetectors as well as to the following Modules andinterfaces because of their inputs:ModulesDetection PointsCZM 0004 Aup to 4 IOP 0008 Aup to 8 RMH 0002 Aup to 2 ENO 0000 Brequires 1 detection point only if a FSErelease element is connected andprogrammed using the FSP-5000-RPSprogramming softwareFPP 5000 TI2 Interface modulesDetection PointsFLM-420/4 CONup to 2 FLM-420-I8R1-Sup to 8 FLM-420-I2up to 2 FLM-420-O8I2-Sup to 2 FLM-420-O1I1up to 1 FLM-420-RHVUp to 2 FLM-420-RLE-Sup to 2 Certifications and approvalsThe provided options according to EN 54 2:1997/A1:2006 include: Output to fire alarm devices Control of fire alarm routing equipment Output to fire alarm routing equipment3 | FPA 5000 With Functional Modules Alarm confirmation input from fire alarm routingequipment Outputs to fire protection equipment Output type A Output type B Output type C Fault monitoring of fire protection equipment Delays to outputs Dependencies on more than one alarm signal Type A dependency Type B dependency Alarm counter Fault warning condition Fault signals from points Total loss of the power supply Output to fault warning routing equipment Disabled condition Disablement of adressable points Test conditionRegionRegulatory compliance/quality marksGermanyVdS-SS205106 BS FPA4620/DT/2010 FPA-5000 GermanyVdSG 205106 (B) FSA 5000 (E)

8 FSA 5000 LSNS witzerlandVKFAEAI 19197 FPA-1200_FPA-5000 BrandmeldesystemEuropeCEFPA-5000 CPD0786-CPD-20818 FPA 5000 AustriaPFB007/BM-PSys/019 FPA-1200/5000 BrandmeldesystemPFB007/BM-PSys/020 FPA-1200/5000 BrandfallsteuerzentralePFB007/BM-PSys/02 1 FPA-5000 Hierarch-ieBelgiumBOSECTCC2-894 FPA 1200_FPA 5000 PolandCNBOP1793/2013 FPA 5000/1200 system certi-fikat EN54-13 HungaryTMTTMT-32/2005 FPA-5000 SingaporePSBCLS1B 13068137901 FPA-5000 Installation/configuration notes Country-specific standards and guidelines must beconsidered during planning. Connection conditions for the regional authoritiesand institutions (police, fire service) must bemaintained. It is preferable to use the loop formation owing to thegreater security of loop lines compared with stublines. Consider the system limit for the number of LSNelements. It is possible to combine LSN interface Modules andLSN detectors on one loop or stub line.

9 For a mixed connection of LSN classic elements andLSN improved elements, a maximum of 127 elementsare permitted. Existing conventional detectors can be connected toa CZM 0004 A module. A CZM 0004 A moduleprovides four DC primary lines (zones). In accordance with EN 54-2, control panels with morethan 512 detectors / call points must be connectedredundantly. To that end, a second basic housingwith a second MPC Panel Controller is used. For operation of the fire detection system accordingto EN 54-13, it is necessary to terminate every stuband T-tap with system Limits Max. numberPanels/remote keypads/OPC server in thenetwork Ethernet / CAN loop32 CAN bus8 LSN elements Stand-alone panel4096 Per network panel2048 Total network32768 Limits per fire panelMax. numberSets, bypass group192 Functional modules46 Printer4 Alarm counters (external, internal, testing)3 Entries in the event database10000 FSP-5000-RPS configuration interfaces (USB,COM)2 Maximum number of outputs (sounders,controls, etc.)

10 Activated in parallel due to thesame event508 Configuration limits per fire panel (FSP-5000-RPS)Max. numberTime channels20 Time control programs19 Configuration for a Specific Day3654 | FPA 5000 With Functional ModulesPermission levels4 User profiles200 system Limits Functional ModulesFunctional moduleMax. numberBCM-0000-B8 ANI 0016 A32 LSN 0300 A32 LSN 1500 A11 FPE-5000-UGM4 CZM 0004 A32 IOS 0020 A4 IOS 0232 A4 ENO 0000 B8 IOP 0008 A32 RML 0008 A32 RMH 0002 A32 NZM 0002 A8 system Limits for each LSN 0300 A Module Up to 254 LSN improved version elements or 127classic LSN elements can be connected Output current LSN 0300 A: up to 300 mA LSN 1500 A: up to 1500 mA Cable length LSN 0300 A: up to 1600 m LSN 1500 A: up to 3000 m Unshielded cables can be usedNoticeOwing to the Planning Software by Bosch, theplanning of fire panels in compliance with thelimits ( concerning cable length and powersupply) is quick and Notes Fire panels can only be installed in dry, clean interiorrooms.