Fire Alarm Systems | FPA 5000 With Functional ModulesFPA 5000 With Functional Modules uModular configuration allowing for easy extensionuInterconnection of up to 32 Panel Controllers,Remote Keypads, and OPC serversuMultiple CAN loop connection with high-performance Ethernet backbone and redundancyuInstallation and auto-detection of functionalmodules by simply plugging them into the panel railuConnection to BIS Building Integration System viaOPC serverThanks to the modular configuration, the innovativeFPA 5000 Modular Fire Panel easily adapts to localcircumstances and regulations. Due to the differentfunctional Modules , country-specific characteristicsare accommodated in the connection just as quickly asthe respective alarm fire panel is available with two different housings: Housing for mounting directly on the wall Frame installation housings which are fitted to themounting frame and can be swiveledWith the aid of special mounting kits, the housings canbe mounted in mm (19") cabinets.

programmed accordingly in the FSP-5000-RPS Programming Software. This applies to all manual call points and automatic detectors as well as to the following modules and interfaces because of their inputs: Modules Detection Points CZM 0004 A up to 4 IOP 0008 A up to 8 RMH 0002 A up to 2 ENO 0000 B requires 1 detection point only if a FSE

Tags:

  Programming, Software, Rps programming software

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Advertisement

Transcription of FPA‑5000 With Functional Modules

1 Fire Alarm Systems | FPA 5000 With Functional ModulesFPA 5000 With Functional Modules uModular configuration allowing for easy extensionuInterconnection of up to 32 Panel Controllers,Remote Keypads, and OPC serversuMultiple CAN loop connection with high-performance Ethernet backbone and redundancyuInstallation and auto-detection of functionalmodules by simply plugging them into the panel railuConnection to BIS Building Integration System viaOPC serverThanks to the modular configuration, the innovativeFPA 5000 Modular Fire Panel easily adapts to localcircumstances and regulations. Due to the differentfunctional Modules , country-specific characteristicsare accommodated in the connection just as quickly asthe respective alarm fire panel is available with two different housings: Housing for mounting directly on the wall Frame installation housings which are fitted to themounting frame and can be swiveledWith the aid of special mounting kits, the housings canbe mounted in mm (19") cabinets.

2 All housingscan be extended with various additional housings forall conceivable FMR 5000 Remote Keypad offers the decentralizedoperation of a control panel or control panel to the external CAN and Ethernet interfaces,several Panel Controllers and Remote Keypads can beinterconnected. Using either a single loop structure ormultiple loop structures with Ethernet backbone, thenetwork can be adapted to nearly every Network1 Fire panel2 Remote KeypadAdditionally, the Ethernet interfaces allow theconnection to: Building Management System BIS,Voice Alarm System Praesideo/PAVIRO, RemoteServices, FSM-2500/FSM-5000 Fire systems can be connected to the BoschUGM Universal Security System and thus, beintegrated into a large network entire fire detection system is configured via alaptop using the FSP-5000-RPS overviewNITUONITUO#0*895623741?

3 PQRSTUVWXYZGHIJKIMNOABC DEFF i r eTestCity TieCity Tie FaultGround FaultBattery FaultPowerTroubleSignal SilenceBypassedSupervisoryNETZEINNETZSTR OMSt rungBATTERIE1St rungBATTERIE2St rungFAULTMAIN+-BAT1+-BAT2+-BAT1+- +-FAULTACFAULTAUX3+-AUX4+-AUX2+-AUX1+-AU X5+-AUX6+-BCM0000AL S N 0 3 0 0 AAU X 1+ -L S N 1a -b +AU X 2+ -L S N 2a -b +ZONE4St rungZONE3St rungZONE2St rungZONE1St rungCZM0004 AAUX1+ -OUT1+-IN1+-AUX2+ -OUT2+-IN2+-AUX3+ -OUT3+-IN3+-AUX4+ -OUT4+-IN4+-ANI0016AF2F1NC1NO1C1NC2NO2C2 FB1+-FB2+ -RELAIS2St rungRELAIS1St rungRMH0002 AOUT3 OUT2 OUT4 OUT6 OUT5 OUT7 GNDOUT8 GNDGNDGNDIN1IN3IN2IN4IN6IN5IN7 GNDIN8 GNDGNDGNDOUT1 IOP0008AC D H L M B E F G I A A ModulesBAddress Cards / Licencse KeysCPanel ControllerDDistributor, optionalEPanel Rail ShortFPower Supply Bracket (installed in Frame Installation Housingsex-works)GPower SupplyHHousing (in this case HCP 0006 A)IPanel Rail LongLBatteriesMRemote KeypadFunctionsOperation / processing of messagesThe operation and the processing of all messages areeasy and intuitive thanks to the ergonomically-designed control panel with its TFT touch screenoffering a menu-driven handling and multi-colordisplay.

4 To that end, there are permanently locatedkeys on the right, bottom, and upper edge of thedisplay as well as variably located virtual keys in thetouch-screen StructureDue to its modular structure, the FPA-5000 ModularFire Panel provides complete flexibility and thuscustomized solutions for any on the requirements, the followingselection can be made when planning:1. Housing type: Frame installation or wall-mount Selection of a basic housing Optional Extension Housings Optional Power Supply Housings Optional kits for installation in 48 cm (19'') racks2. Operating and Display Unit with Panel Controller Selection from the various language variants3. Panel Rail Selection according to housing type and/ornumber of required Functional modules4.

5 Functional Modules Selection based on planning and country-specificrequirements5. Power supply Batteries Additional power supply facilities Power Supply Brackets are preinstalled ex-worksfor Frame Installation Housings For Wall-mount Housings, Power Supply Bracketsare selected as needed6. Additional accessories Front Doors Printer with Frame Installation Housing Cable Sets for special applicationsModulesThe Functional Modules are autonomous, encapsulatedunits that can be inserted into any control panel slotusing plug-and-play technology. Thus, the powersupply and the data traffic to the control panel areindicated automatically without any additionalsettings.

6 The module is automatically identified by thecontrol panel and functions in the default to external components is performed usingcompact connector/screw a replacement, only the connectors need to bereinserted; extensive rewiring is no longer | FPA 5000 With Functional ModulesModuleDescriptionBCM-0000-BBatter y Controller Module module that controls batteries and powersupplyANI 0016 AAnnunciator Module with 16 red and 16 yellow LEDs, freelyprogrammableLSN 0300 ALSN improved Module 300 mA for the connection of an LSN loop with upto 254 LSN improved elements or 127standard LSN elements, maximum linecurrent 300 mALSN 1500 ALSN improved Modul 1500 mA for the connection of an LSN loop with upto 254 LSN improved elements, maximumline current 1500 mA, or with up to 127standard LSN elements.

7 Maximum linecurrent 300 mAFPE-5000-UGMI nterface Module for the connection to a UGM 2020 SystemCZM 0004 A4 Zone Conventional Module for the connection of existing conventionalperipherals, with 4 monitoredconventional linesIOS 0020 A20 mA Communication Module with an S20 interface and an RS232interface for a connection with a voice alarm systemPlena via RS232 IOS 0232 ARS232 Communication Module with two RS232 interfaces for a connection with a voice alarm systemPlena , a printer or laptopENO 0000 BFire Service Interface Module for the connection to fire serviceequipment according to DIN 14675 IOP 0008 AInput/Output Module with 8 digital inputs and 8 open collectoroutputsRML 0008 ARelay Module with 8 relays for low voltage applicationsRMH 0002 ARelay Module with 2 relays for mains power (250 V) andwith feedback inputs (can also be used asan interface to extinguishing systems)

8 NZM 0002 ANotification Appliance Zone Module with 2 monitored primary linesNetworkingUp to 32 Panel Controllers, Remote Keypads and OPCserver can be interconnected within a on the application requirements, PanelControllers and Remote Keypads can be grouped,defined as network node or local node. Within a group,only panel conditions of the same group can bedisplayed. Regardless of the groups, network nodesallow for the display and handling of all panelconditions. Local nodes display the conditions of therelated networking via CAN and/or Ethernet interfaces,the following connection topologies are optional: Redundant loop via CAN1 and CAN2 (max. 32 nodes) Ethernet loop (max.)

9 32 nodes) Multiple CAN loops with Ethernet backbone and up to32 nodesFor networking with optical fibers, you can use variousconverters. For detailed information on suitableconverter types and maximum line lengths, refer to theFPA-5000 Networking Guide (available for download).Detection PointsThe Address Cards activate detection points. TheFPA-5000 governs up to 4096 detection element and input which is able to set off analarm requires a detection are considered as detection points if they areprogrammed accordingly in the FSP-5000-RPSP rogramming applies to all manual call points and automaticdetectors as well as to the following Modules andinterfaces because of their inputs.

10 ModulesDetection PointsCZM 0004 Aup to 4 IOP 0008 Aup to 8 RMH 0002 Aup to 2 ENO 0000 Brequires 1 detection point only if a FSErelease element is connected andprogrammed using the FSP-5000-RPSprogramming softwareFPP 5000 TI2 Interface modulesDetection PointsFLM-420/4 CONup to 2 FLM-420-I8R1-Sup to 8 FLM-420-I2up to 2 FLM-420-O8I2-Sup to 2 FLM-420-O1I1up to 1 FLM-420-RHVUp to 2 FLM-420-RLE-Sup to 2 Certifications and approvalsThe provided options according to EN 54 2:1997/A1:2006 include: Output to fire alarm devices Control of fire alarm routing equipment Output to fire alarm routing equipment3 | FPA 5000 With Functional Modules Alarm confirmation input from fire alarm routingequipment Outputs to fire protection equipment Output type A Output type B Output type C Fault monitoring of fire protection equipment Delays to outputs Dependencies on more than one alarm signal Type A dependency Type B dependency Alarm counter Fault warning condition Fault signals from points Total loss of the power supply Output to fault warning routing equipment Disabled condition Disablement of adressable points Test