Example: confidence

GB-250 - schier

GB-250 . Submittal | Special Precautions | Specifications | Installation | Application Specific Details 68". ( cm). 13 ". (343. ( ). cm). 51 ". (( cm). 38". ( (965 cm). m). 33 ". ( cm). SUBMITTAL. STANDARD: 4" plain end inlet/outlet | Capacities - Liquid: 275 gal. (1,041 L); Grease: 1,076 lbs. ( kg) ( L); Solids: 105 gal. ( L);. Highway tra c load rated, bolted, gas/water tight composite covers. (16,000 lbs.). OPTIONS: APPROVAL: 4" Male Thread Inlet/Outlet High Water Anchor Kit Signature: 6" Plain End Inlet/Outlet TeleGlide Risers 6" Male Thread Inlet/Outlet SR24 (x2) 5" 23" Date: (stainless steel) LR24 (x2) >23" 38".)

9500 Woodend Road | Edwardsville, KS 66111 | Tel: 913-951-3300 | Fax: 913-951-3399 | www.schierproducts.com © Copyright 2017 Schier, All Rights Reserved MODEL NUMBER ...

Tags:

  Gb 250

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Advertisement

Transcription of GB-250 - schier

1 GB-250 . Submittal | Special Precautions | Specifications | Installation | Application Specific Details 68". ( cm). 13 ". (343. ( ). cm). 51 ". (( cm). 38". ( (965 cm). m). 33 ". ( cm). SUBMITTAL. STANDARD: 4" plain end inlet/outlet | Capacities - Liquid: 275 gal. (1,041 L); Grease: 1,076 lbs. ( kg) ( L); Solids: 105 gal. ( L);. Highway tra c load rated, bolted, gas/water tight composite covers. (16,000 lbs.). OPTIONS: APPROVAL: 4" Male Thread Inlet/Outlet High Water Anchor Kit Signature: 6" Plain End Inlet/Outlet TeleGlide Risers 6" Male Thread Inlet/Outlet SR24 (x2) 5" 23" Date: (stainless steel) LR24 (x2) >23" 38".)

2 Company: Pedestrian Rated Covers - 2, 000 lbs. SR24 (x4) >38" 43". H20 Load Rated Pickable SR24 (x2) + LR24 (x2) >43" 58" Specifying Engineer: Cast Iron Covers LR24 (x4) >58" 72". Integral Membrane Engineering Firm: Clamping Collar Kit Pumpout Port (Large). MODEL NUMBER: DESCRIPTION: Polyethylene Grease Interceptor GB-250 100 GPM - 275 gallon capacity PART #: 4055-001-XX DWG BY: B. Karrer DATE: 10/08/2015 REV: 3 10/13/2017 ECO: 9500 Woodend Road | Edwardsville, KS 66111 | Tel: 913-951-3300 | Fax: 913-951-3399 | Copyright 2017 schier , All Rights Reserved 057-0870-02 page 1 of 7.

3 SPECIAL PRECAUTIONS. For All schier Grease Interceptor Installations Installation Instructions High Temperature Kitchen Water Installation instructions and additional components are located inside If water is entering the interceptor at excessive temperature (over 140 F), the interceptor. Read all instructions prior to installation. This interceptor a drain water tempering valve (DTV) must be installed. Most state and is intended to be installed by a licensed plumber in conformance with all local plumbing codes prohibit water above 140 F being discharged into local codes.

4 The sanitary sewer. Water above 140 F will weaken or deform PVC. Schedule 40 pipe, poly drainage xtures like interceptors and erode the coating of cast iron (leading to eventual failure). Failure to follow this guidance voids your warranty. high temperature drain water e uent ( > 140 F) tempering valve (DTV). cold water supply line Interceptor When Installing Interceptor Inside If your dishwashing sink(s) discharges into a oor drain/sink (drain), you High Water Table Installations must regulate the ow into the drain to avoid an over ow of water onto Interceptors and risers are not designed to withstand water table height in the kitchen oor.

5 This can be done by installing a valve or ow restriction excess of the top of the unit when buried (see gure). If it is possible for this cap on the sink piping that discharges into the drain. See drawing below to occur, install the interceptor and risers in a water-tight concrete vault or for guidance. For detailed guidance on indirect connections, go to: back ll with concrete or owable ll (wet concrete and owable back ll should be poured in stages to avoid crushing the interceptor). At risk areas include but are not limited to tidal surge areas, oodplains and areas that receive storm water.

6 Failure to follow this guidance voids your warranty. Fernco or similar rubber ow Models GB-50, GB-75, and GB-250 that are direct buried in high water restriction end cap table scenarios must be installed with model AK1 anchor kit or warranty is void. max water table height for direct burial Interceptor Interceptor Hydrostatic Slabs (or Pressure Slabs). model AK1. When installed under a hydrostatic slab (slab designed to withstand anchor kit upward lift, usually caused by hydrostatic pressure) interceptor must be enclosed in a watertight concrete vault. Failure to follow this guidance voids your warranty.

7 Concrete slab subject to Interceptor hydrostatic pressure watertight concrete vault MODEL NUMBER: DESCRIPTION: Polyethylene Grease Interceptor GB-250 100 GPM - 275 gallon capacity PART #: 4055-001-XX DWG BY: B. Karrer DATE: 10/08/2015 REV: 3 10/13/2017 ECO: 9500 Woodend Road | Edwardsville, KS 66111 | Tel: 913-951-3300 | Fax: 913-951-3399 | Copyright 2017 schier , All Rights Reserved 057-0870-02 page 2 of 7. SPECIFICATIONS Highway tra c load rated, bolted, gas/water tight 16". composite covers. (16,000 lbs.). Outlet A. NOTES (optional). 1. 4" plain end inlet/outlet 2. Unit weight - w/composite covers: 230 lbs.

8 ; w/cast A A. iron covers: 340 lbs. (For wet weight add 2290 lbs.). 3. Maximum operating temperature: 140 F continuous 4. Capacities - Liquid: 275 gal.; Grease: 1,076 lbs. ( Inlet Outlet B. gal.); Solids: 105 gal. (standard). 5. Built-in Flow control. 6. For gravity drainage applications only. 33-1/2". 7. Do not use for pressure applications. 8. Cover placement allows full access to tank for proper maintenance. 9. Vent not required unless per local code. Outlet C. 10. Engineered inlet and outlet di users are removable (optional). to inspect/clean piping. 11. Integral air relief / Anti-siphon / Sampling access.

9 TOP VIEW. DIFFUSION FLOW TECHNOLOGY. 68". The inlet di user splits in uent into three paths, creating laminar ow and utilizing the entire liquid volume of the tank 24-1/2" TYP. for e cient grease separation. The calibrated openings 7-1/2". greatly reduce e uent turbulence. The e uent enters the Integral main chamber without disturbing the existing grease or air-relief/. sediment layers. 13-1/2". anti siphon The integral air relief / anti-siphon in the top of the outlet di user allows pressure stabilization within the unit during e uent which is free of grease to exit the tank.

10 It can easily CL of inlet & outlet 51-1/2". site piping layouts. Static water line ENGINEER SPECIFICATION GUIDE Engineered inlet 35-3/4". 38" and outlet di user Invert schier Great Basin grease interceptor model # GB-250 . w/inspection port shall be lifetime guaranteed and made in USA of seamless, rotationally-molded polyethylene. Interceptor shall be furnished for above or below grade installation. Interceptor shall be certi ed to ASME (type C) and CSA , with eld adjustable riser system, built-in ow control, built-in test caps and three outlet options. Interceptor ow rate shall be 100 GPM.