sv24 . Wastewater Sampling Port Technical Data Submittal | Special Precautions | Specifications | Installation 24 ". 24 " 24 ". 24 ". ( cm) ( cm). 12 " 12 " 12 " 12 ". 16 ". ( cm) ( cm) ( cm) ( cm). ( 24 " 24 ". ( cm) ( cm). 12". ( cm). 8". 12" 12" ( cm). ( cm) ( cm). sv24 -L sv24 -O. SUBMITTAL. STANDARD: 4" plain end inlet/outlet | Highway tra c load rated, bolted, gas/water tight composite covers. (16,000 lbs.). OPTIONS: APPROVAL: -L Level Connections TeleGlide Risers Signature: -O O set Connections SR24 (x1) 4-1/2" 23". 4M 4" Male pipe thread connection LR24 (x1) >23" 37-3/4" Date: 6P 6" Plain End SCH.)

18" min. 12" minimum clear around entire unit 8" min. Flow from grease interceptor Flow to sanitary sewer ø 24-1/2" 057-1080-03 9500 Woodend Road | Edwardsville, KS ...

Tags:

  Sv24

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Advertisement

Transcription of SV24 - schier

1 sv24 . Wastewater Sampling Port Technical Data Submittal | Special Precautions | Specifications | Installation 24 ". 24 " 24 ". 24 ". ( cm) ( cm). 12 " 12 " 12 " 12 ". 16 ". ( cm) ( cm) ( cm) ( cm). ( 24 " 24 ". ( cm) ( cm). 12". ( cm). 8". 12" 12" ( cm). ( cm) ( cm). sv24 -L sv24 -O. SUBMITTAL. STANDARD: 4" plain end inlet/outlet | Highway tra c load rated, bolted, gas/water tight composite covers. (16,000 lbs.). OPTIONS: APPROVAL: -L Level Connections TeleGlide Risers Signature: -O O set Connections SR24 (x1) 4-1/2" 23". 4M 4" Male pipe thread connection LR24 (x1) >23" 37-3/4" Date: 6P 6" Plain End SCH.)

2 40 Inlet/Outlet SR24 (x2) >37-3/4" 42-1/2". Company: C24M Pedestrian rated cover SR24 (x1) + LR24 (x1) >42-1/2" 57-1/2". (2,000 lbs.) LR24 (x2) >57-1/2" 72" Specifying Engineer: C24HP H20 Load Rated Pickable Cast Iron Covers Engineering Firm: MODEL NUMBER: DESCRIPTION: Polyethylene Wastewater Sampling Port sv24 . PART #: Level: 8063-001-03 | O set: 8062-001-03 DWG BY: B. Karrer DATE: 2/25/2016 REV: 3 - 10/13/2017 ECO: 1067. 9500 Woodend Road | Edwardsville, KS 66111 | Tel: 913-951-3300 | Fax: 913-951-3399 | Copyright 2018 schier , All Rights Reserved 057-1080-03 page 1 of 5. SPECIAL PRECAUTIONS. For All schier Grease Interceptor Installations - Failure to follow this guidance voids your warranty Installation Instructions High Temperature Kitchen Water Installation instructions and additional installation If water is entering the interceptor at excessive temperature (over 140 F), a components are included with the instructions drain water tempering valve (DTV) and approved back ow prevention assembly interceptor.

3 Read all instructions prior must be installed. Most state and local plumbing codes prohibit water above to installation. This interceptor is 140 F being discharged into the sanitary sewer. Water above 140 F will weaken intended to be installed by a licensed or deform PVC Schedule 40 pipe, poly drainage xtures like interceptors and plumber in conformance with all erode the coating of cast iron (leading to eventual failure). local codes. cold water supply line When Installing Interceptor Inside high temperature e uent ( > 140 F). If your dishwashing approved back ow prevention assembly sink(s) discharges DTV (drain water tempering valve).

4 Into a oor drain/. sink (drain), you must regulate the ow into the drain to avoid an over ow of water onto the kitchen oor. This Fernco or similar Interceptor can be done by rubber ow Interceptor installing a valve or restriction end cap ow restriction cap on the sink piping that discharges into the drain. See drawing above for guidance. For detailed guidance on indirect connections, go to: directly connected indirectly connected Hydrostatic Slabs concrete slab subject Fully Support (or Pressure Slabs) to hydrostatic pressure concrete oor When installed under a hydrostatic Base of Unit slab (slab designed to withstand Install unit on solid, level surface in upward lift, usually caused by contact with the entire footprint of Interceptor hydrostatic pressure) interceptor Interceptor unit base; for suspended installations must be enclosed in a watertight design trapeze to support the wet concrete vault.

5 Weight of the unit. Do not partially support unit or suspend unit using watertight concrete vault metal U-channel to create a trapeze suspended installation High Water Table Installations Support Inlet and pipe supports Interceptors and risers are not max water table Outlet Piping designed to withstand water table height for direct burial height in excess of the top of the unit For above grade installations ensure when buried (see gure). If it is heavy inlet and outlet piping (such as possible for this to occur, install the cast iron or long runs) is properly Interceptor interceptor and risers in a water-tight supported or suspended during the concrete vault or back ll with entire installation process to prevent concrete or owable ll (wet concrete Interceptor connection failure or damage to and owable back ll should be poured bulkhead ttings.)

6 In stages to avoid crushing the interceptor). At risk areas include but are not limited to tidal surge areas, model AK1 anchor kit oodplains and areas that receive storm water. Models GB-50, GB-75, and GB-250 that are direct buried in high water table scenarios must be installed with model AK1 anchor kit. MODEL NUMBER: DESCRIPTION: Polyethylene Wastewater Sampling Port sv24 . PART #: Level: 8063-001-03 | O set: 8062-001-03 DWG BY: B. Karrer DATE: 2/25/2016 REV: 3 - 10/13/2017 ECO: 1067. 9500 Woodend Road | Edwardsville, KS 66111 | Tel: 913-951-3300 | Fax: 913-951-3399 | Copyright 2018 schier , All Rights Reserved 057-1080-03 page 2 of 5.

7 SPECIFICATIONS Bolted and gasketed composite cover NOTES. 1. 4" plain end inlet/outlet 2. Unit weight - 65 lbs. 3. Unit supplied with built-in adapter for up to 3" of A. continuous adjustability. Additional riser(s) are also A. available for deeper burial depth. 4. Maximum operating temperature: 140 F continuous ENGINEER SPECIFICATION GUIDE. schier Sewer Viewer sampling port model # sv24 shall be manufactured by schier Products, Edwardsville, KS. Port shall be lifetime guaranteed and Made in USA of seamless, rotationally molded polyethylene. TOP VIEW. OUTLET END VIEW. 24-1/2" 24-1/2". 12-1/2" 12-1/2".

8 CL of inlet & outlet CL of inlet 16-1/2". 24-1/2" 24-1/2". CL of outlet 12" 12". 8". sv24 -L sv24 -O. SECTION A-A (Level Connections) SECTION A-A (O set Connections). MODEL NUMBER: DESCRIPTION: Polyethylene Wastewater Sampling Port sv24 . PART #: Level: 8063-001-03 | O set: 8062-001-03 DWG BY: B. Karrer DATE: 2/25/2016 REV: 3 - 10/13/2017 ECO: 1067. 9500 Woodend Road | Edwardsville, KS 66111 | Tel: 913-951-3300 | Fax: 913-951-3399 | Copyright 2018 schier , All Rights Reserved 057-1080-03 page 3 of 5. INSTALLATION (1 of 2). WARNING! DO NOT AIR TEST UNIT OR FIELD CUT. RISER SYSTEM! Doing so may result in property damage, 18" 24-1/2" 12" minimum personal injury or death.

9 Min. clear around entire unit LEAK/SEAL TESTING. 8" min. Cap/plug all base unit plumbing connections and remove covers. For base unit testing, ll with water to just above the highest connection. For riser system testing (if required) ll with water to nished grade level. CAUTION: Risers must be supported before lling Flow from with water to prevent tipping. Inspect unit, connections and all gaskets and clamps (if grease Flow to applicable) for leaks. Check water level at speci c time intervals per local code. interceptor sanitary sewer GENERAL INSTALLATION INSTRUCTIONS. Consult local codes for separate trapping requirements, cleanout locations and additional installation instructions.

10 1. Set unit on level solid surface. 2. If unit is to be suspended above the oor ensure bottom of unit is fully supported. 3. Connect inlet and outlet drainage lines to unit. Mechanically couple pipes to unit. Do not solvent weld. 4. For unit with cast iron covers, remove retainer clips prior to burial. EXCAVATION AND BACKFILL DETAIL. NOTE: Do not install below a hydrostatic slab. BELOW GRADE INSTALLATION. INSTRUCTIONS. EXCAVATION Flow from grease 1. Surrounding soil must be undisturbed soil or interceptor well compacted engineering ll. 2. Width and length of excavation shall be a Flow to minimum of 12" greater than the tank on all sanitary sides and depth shall be 6" deeper than sewer tank bottom.