GL6000-STD - Diesel Generator

GL6000-STD GL6000-AUSGL7000-USA GL7000-USA-TM GL7000-STDGL9000-STD GL9000-AUSGL11000-USA GL11000-USA-TM GL11000-STDD-2396D-2397 ENGLISHTo prevent electrical shock the following instruction must be the Generator can be connected to a building s electrical system, a licensed electrician must install an isolation (transfer) switch in the building s main fuse box. The switch is the connection point for Generator power and allows selection of Generator or main line power to the will prevent the Generator from charging the main power line (backfeeding) when the main power supply has failed or has been turned off for line repair. Backfeeding can electrocute or injure line maintenance personnel. Also, Generator and building electrical system damage can occur when normal operating power returns if unit is used without an isolation WARNINGWARNINGIMPORTANTThe engine in this machine is not equipped by the manufacture with a standard spark is a violation of California Public Resource Code Section 4442 to use or operate this engine on or near any forest-covered, brush-covered land, or grass- covered land unless the exhaust system

ENGLISH. To prevent electrical shock the following instruction must be followed. Before the generator can be connected to a building’s electrical

Tags:

  Generators

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of GL6000-STD - Diesel Generator

1 GL6000-STD GL6000-AUSGL7000-USA GL7000-USA-TM GL7000-STDGL9000-STD GL9000-AUSGL11000-USA GL11000-USA-TM GL11000-STDD-2396D-2397 ENGLISHTo prevent electrical shock the following instruction must be the Generator can be connected to a building s electrical system, a licensed electrician must install an isolation (transfer) switch in the building s main fuse box. The switch is the connection point for Generator power and allows selection of Generator or main line power to the will prevent the Generator from charging the main power line (backfeeding) when the main power supply has failed or has been turned off for line repair. Backfeeding can electrocute or injure line maintenance personnel. Also, Generator and building electrical system damage can occur when normal operating power returns if unit is used without an isolation WARNINGWARNINGIMPORTANTThe engine in this machine is not equipped by the manufacture with a standard spark is a violation of California Public Resource Code Section 4442 to use or operate this engine on or near any forest-covered, brush-covered land, or grass- covered land unless the exhaust system is equipped with a working spark arrester meeting state laws.

2 Other states or federal areas may have similar Proposition 65 Engine exhaust, some of its constituents, certain vehicle components and fluids, contain or emit chemicals known to the State of California to cause cancer and birth defects or other reproductive :3 WARNING :3 CAUTION :IMPORTANT :NOTE :3 SAFETY FIRSTYou are now the proud owner of a KUBOTA Diesel Engine Generator . This Generator is a product of KUBOTA quality engineering and manufacturing. It is made of fine materials and under a rigid quality control system with correct maintenance. It will give you long, satisfactory service. To obtain the best use of your Generator , please read this manual carefully. It will help you become familiar with the operation of the Generator and contains many helpful hints about Generator maintenance.

3 It is KUBOTA's policy to utilize as quickly as possible every advance in our research. The immediate use of new techniques in the manufacture of products may cause some small parts of this manual to be outdated. KUBOTA distributors and dealers will have the most up-to-date information. Please do not hesitate to consult with symbol, the industry's "Safety Alert Symbol", is used throughout this manual and on labels on the machine itself to warn of the possibility of personal injury. Read these instructions carefully. It is essential that you read the instructions and safety regulations before you attempt to assemble or use this an imminently hazardous situation which, if not avoided, will result in death or serious a potentially hazardous situation which, if not avoided, could result in death or serious a potentially hazardous situation which, if not avoided, may result in minor or moderate that equipment or property damage could result if instructions are not helpful PRECAUTIONS.

4 1 SERVICING OF Generator .. 1 SPECIFICATION .. 4 GROUND FAULT CIRCUIT INTERRUPTER (GFCI) RECEPTACLE .. 8 PREPARATION TO SUPPLY THE ELECTRIC POWER .. 10 CONNECTING THE 12 PRE-OPERATION 16 OPERATING THE 19 SERVICE INTERVALS .. 23 PERIODIC 25 TRANSPORTING / 38 AUTOMATIC START/STOP UNIT (A S/S UNIT).. 40 WIRING 411 SAFETY PRECAUTIONSENGLISHSAFETY PRECAUTIONSATo operate the machine safely, be sure to follow the instructions avoid personal injury:AHazard of being caught up in the machine: Donot touch any rotating not use or charge the battery if its fluid levelstands below the LOWER , the component parts may deteriorateearlier than expected, which may shorten theservice life or cause an explosion. Immediately,add distilled water until the fluid level is betweenthe UPPER and LOWER levels.

5 (for only refillablebattery)WARNINGTo avoid personal injury:AExhaust gas poisoning hazard: Do not use themachine in any poorly-ventilated place such asindoors and gas poisoning and fire hazard: Do notdirect the exhaust to people and shock hazard: Do not touch the machinewith wet shock hazard: Do not touch theterminals and sockets while the machine shock and injury hazard: Do not checkand service the machine while it is shock and injury hazard: Do not tamperwith the hazard: Flames prohibited. Keep themachine more than 1 m(3 feet) away fromflammable shock hazard: Do not use the machine inthe PRECAUTIONSENGLISHCAUTIONTo avoid personal injury:AElectric shock and fire hazard: Do not connectthe machine to any indoor (commercial) shock and injury hazard: Do not allowchildren to run the shock and injury hazard: Turn off thecircuit breaker before starting the hazard: Do not touch the hazard: Do not run the machine hazard: Do not move the machine while itis hazard: Stop the engine before adding hazard: Do not enclose the machine, norcover it with a box or the hazard.

6 Pay attention to the type andamount of not get the warning label dirty or peeled sure to hand over the operation manual toany other shock hazard: Ground the machineusing the ground terminal on the control PRECAUTIONSENGLISHCAUTIONTo avoid personal injury:AAnti-freeze contains poison. Wear rubber glovesto avoid personal injury. In case of contact withskin, wash it off NOT mix different types of Anti-freeze. Themixture can produce chemical reaction causingharmful substances. Use approved mindful of the environment and the draining any fluids, find out the correctway of disposing of them. Observe the relevantenvironmental protection regulations whendisposing of oil, fuel, coolant, brake fluid, filtersand draining fluids from the engine, placesome container underneath the engine NOT pour waste onto the grounds, down adrain, or into any water PRECAUTIONSENGLISHCAUTIONTo avoid personal injury:AWhen checking engine or servicing, place theengine on a wide and level ground.

7 DO NOT workon anything that is supported ONLY by lift jacksor a hoist. Always use blocks or correct standsto support the engine before the battery from the engine beforeconducting service. Put a "DO NOT OPERATE!"tag in the key switch to avoid accidental avoid sparks from an accidental short circuitalways disconnect the battery's ground cable (-)first and connect it sure to stop the engine and remove the keywhen conducting daily and periodicmaintenance, servicing and or conduct maintenance after the engine,coolant, muffler, or muffler cover have beencooled off use the appropriate tools and jig-fixturein good condition when performing any servicework. Make sure you understand how to usethem before ONLY correct engine barring techniques formanually rotating the engine.

8 DO NOT attempt torotate the engine by pulling or prying on thecooling fan and V-belt. This practice can causeserious personal injury or premature machinedamage to the cooling fuel pipes and lubricant pipes with theirhose clamps every 2 years or earlier whetherthey are damaged or not. They are made ofrubber and are aged servicing is performed together by two ormore persons, take care to perform all first aid kit and fire extinguisher handy atall PRECAUTIONSENGLISHDANGER, WARNING AND CAUTION LABELSPay special attention to all labels on the to following representations for labels used on the GL Series Generator . Labels are avail-able individually from your KUBOTA Dealer.(1) Part No. G3907-8832-0(2) Part No. G3907-8830-0(3) Part No. G3907-8836-0(4) Part No.

9 G3907-8831-0(5) Part No. G3102-5090-2 (for USA)(5) Part No. 18901-5090-2(6) Part No. G3907-8824-06 SAFETY PRECAUTIONSENGLISH(7) Part No. 18620-8806-0(8) Part No. G3907-8833-0(9) Part No. G3102-8841-0(10) Part No. G3101-8832-0(11) Part No. 6C040-5559-0(12) Part No. G3102-8806-0(13) Part No. G3906-8831-0(14) Part No. G3102-8838-0 (for )(15) Part No. G3102-8839-0 (for )7 SAFETY PRECAUTIONSENGLISHCARE OF DANGER, WARNING AND CAUTION LABELS1. Keep danger, warning and caution labels clean and free from obstructing Clean danger, warning and caution labels with soap and water, dry with a soft Replace damaged or missing danger, warning and caution labels with new labels from yourlocal KUBOTA If a component with danger, warning and caution label(s) affixed is replaced with new part,make sure new label(s) is (are) attached in the same location(s) as the replaced Mount new danger, warning and caution labels by applying on a clean dry surface andpressing any bubbles to outside OF GENERATORENGLISHSERVICING OF GENERATORYour dealer is interested in your new Generator and hasthe desire to help you get the most value from it.

10 Afterreading this manual thoroughly, you will find that youcan do some of the regular maintenance , when in need of parts or major service, besure to see your KUBOTA service, contact the KUBOTA Dealership fromwhich you purchased your Generator or your localKUBOTA in need of parts, be prepared to give your dealerthe Generator and engine serial the serial numbers now and record them in thespace provided of Purchase Name of Dealer(To be filled in by purchaser)(1) Generator serial number(2) Generator model(3) Engine serial number2 SPECIFICATIONENGLISHSPECIFICATIONGENERAT ORM odelUnitGL6000GL7000 STD AUS USA USA-TM STDD esign Salient-pole, revolving-field AC Generator (AVR system with separate and self-excitation brush)FrequencyHz5060 Rated Output (COP) VoltageV220240120/240110/220 Rated & Wire -W1-21-4 Power Factor%100No.