Transcription of Hi-Performance Series - IEC Environmental …
1 Hi-Performance Series FAN COIL TECHNICAL CATALOG. BUILD YOUR REPUTATION ON OURS. Hi-Performance Series TABLE OF CONTENTS. 2 Table of Contents 3 Portfolio 5 Special Applications 6 Unit Model Key 7 Ratings and Listings 8 Electric Heating 9 Air Delivery 11 Motor Data 13 Physical Data 18 Standard Features and Options 23 Piping Packages (Typical). International Environmental Corporation (IEC) works continually to improve its products. As a result, the design and specifications of each product may be changed without notice and may not be as described herein. Please contact IEC for information regarding current design and product specifications. Statements and other information contained herein are not express warranties and do not form the basis of any bargain between the parties but are merely IEC's opinion or commendation of its products. Manufacturer's standard limited warranty applies. International Environmental Corporation Hi-Performance Series Fan Coil Technical Catalog 2 Hi-Performance Series PORTFOLIO.
2 VEY - Hi-Performance Vertical Cased 600 CFM to 2000 CFM. The Hi-Performance Vertical Cased (VEY) fan coil unit is designed for floor-mounted, vertical, ducted applications. VEY units are typically enclosed in partition walls or located in closets, utility rooms or other concealed locations. VEY. units have a top panel which is provided with a one-inch discharge duct flange and a removable front panel which provides complete access to coils, factory-furnished valve packages, motor-blower and electric-heater assemblies. VEY. units are available with a front or bottom return. Standard VEY units are provided with a galvanized finish. HHY - Hi-Performance Hideaway 600 CFM to 2000 CFM. The Hi-Performance Hideaway (HHY) fan coil unit is designed specifically to meet the many varied requirements for a ceiling hideaway installation where there is a ducted, high-static application. Standard HHY units are provided with a galvanized finish. International Environmental Corporation Hi-Performance Series Fan Coil Technical Catalog 3.
3 Hi-Performance Series PORTFOLIO, Cont'd. HPY - Hi-Performance Hideaway with Plenum 600 CFM to 2000 CFM. The Hi-Performance Hideaway with Plenum (HPY) fan coil unit provides the same basic features as the HHY plus a return air plenum. HPY units are shipped from the factory ready for installation with the plenum section in place. No field fabrication is required. HPY units are designed with interchangeable panels so that the unit may be modified on site to accommodate a rear or bottom return. Standard HPY. units are provided with a galvanized finish. HLY - Hi-Performance Cabinet 600 CFM to 2000 CFM. The Hi-Performance Cabinet (HLY) fan coil unit is suited for under-ceiling, mounted applications where high capacities are required. HLY units are supplied with an integral double- deflection discharge grille and hinged bar type, return air grille with a throwaway filter. Standard HLY units are provided with a powder-coat paint finish. HLY units are not suitable for ducted applications.
4 HXY - Hi-Performance Horizontal Cased 600 CFM to 2000 CFM. The Hi-Performance Cased (HXY) fan coil unit is designed for above or below the ceiling and is ideal for high-static, ducted applications where high output is required. Standard HXY units are fabricated of heavy gauge steel and are provided with a galvanized finish. International Environmental Corporation Hi-Performance Series Fan Coil Technical Catalog 4 Hi-Performance Series SPECIAL APPLICATIONS. Application Fit Optional 6" legs are available for the vertical (VEY) unit. Multiple cabinet choices are available in 8 nominal sizes for application in a variety of room layouts. Customizable cabinetry (HLY or HXY) makes these units ideal for renovation jobs or where special sizes o Hideaway model (HHY) units are installed above are required to fit oversized valves and controls the ceiling with or without ducted supply air and packages. open soffit return with an optional ceiling-mounted return air filter-grille.
5 HPY optional airflow configuration (rear return or bottom return) can be factory configured or field o Hideaway model with plenum (HPY) units are converted for maximum flexibility. installed above the ceiling with or without Wide variety of factory assembled valve packages to ducted supply air and ducted return air. The meet desired controls specifications. return air filter is either mounted on the unit Wide variety of optional insulation materials are plenum or installed in an optional ceiling filter- available to address IAQ concerns. grille. Optional condensate overflow switches are available o Cabinet model (HLY) units are equipped with to address latest building codes where required. a painted cabinet suitable for under-ceiling exposed applications. Specially selected motor Ease of Installation and blower designs make this unit especially Optional factory assembled valve packages minimize suited for non-ducted applications. the piping work at the job site.
6 Optional unit mounted controls, service switches and o Horizontal cased model, high static (HXY) units fusing minimize the electrical work required on site. are equipped with a galvanized cabinet suitable Units are tagged at the factory for clear identification for above or below the ceiling, and are ideal for on the job site. ducted supply and return air. Opposite end connection units may minimize the o Vertical cased units (VEY) are ideal for air field piping work on renovation jobs. conditioning in apartments, offices, schools and many other applications. Top supply units are Ease of Service often located in mechanical rooms and supply All components are accessible by simply removing air is ducted into multiple zones. Front or bottom the access panel. return units with filter frames are available. Filters can be replaced without tools. Blower assembly easily removed from the rear of the Design Flexibility coil for service and cleaning. Easy to use ratings program to speed up project design.
7 Quality and Safety Optional seismic structural upgrade to meet IBC-2009. Standard and high capacity hydronic coils and and OSHPD seismic certification in accordance with DX coils are available to match the heating and ICC-ES-AS-156. cooling loads of the space. Every unit tested and inspected at the factory for Optional powder paint finish colors and grille trouble-free start-up. selections will complement most d cors (HLY units). ETL listed. AHRI rated where applicable. International Environmental Corporation Hi-Performance Series Fan Coil Technical Catalog 5. Hi-Performance Series UNIT MODEL KEY. Code Items 01 02 03 04 05 06 07. Code H H Y 0 8 B 6 S C 2 R 6 C R B. UNIT VINTAGE SIZE COILS/ MOTOR HAND/ CONTROLS. ELECTRIC HEAT ARRANGEMENT. HHY Hi-Performance Hideaway 06 600 CFM Voltage Type HPY Hi-Performance Hideaway with Plenum 08 800 CFM C 115-1-60 2 Permanent Split Capacitor HLY Hi-Performance Cabinet 10 1000 CFM D 208-1-60 A ECM, 3-Spd Relay Brd (L/M/H).
8 HXY Hi-Performance Horizontal Cased 12 1200 CFM E 230-1-60 B ECM, Proportional (0-10 VDC). VEY Hi-Performance Vertical Cased 14 1400 CFM F 277-1-60 C ECM, 4-Spd EVO Board, 16 1600 CFM V 220-1-50* Solid State w/PWM. 18 1800 CFM U 240-1-50*. 20 2000 CFM Hand** Arrangement R Right 5. Two-pipe Cooling and Heating Four-pipe Heating Coil Connection L Left 6. or Four-pipe Cooling Y None Y None 6. A 3-Row 6 1-Row S Same End B 4-Row 7 2-Row O Opposite End HHY. K 6-Row or, if electric heat or, if electric heat 6. Voltage kW. HPY 5. C 120 V D M D 208 V 5. F N 6. E 240 V G P 6. F 277 V H Q HXY. VEY. V 220 V (50)* J 6. U 240 V (50)* K L HLY. Voltage System / Thermostat B 24 V Manual Fan Operation C 120 V A2 Standard Wall Mount (Switch Only). D 208 V Thermostat Function Control E 240 V. G 2 Pipe Heat Only A . TB155 Wall Series , ACO, Vertical Mnt. F 277 V H 2 Pipe Cool Only B . TB155 Wall Series , ACO, Horizontal Mtd. V 220 V (50)* K 2 Pipe Heat and Cool P . Basic 24V Digital Programmable, ACO.
9 U 240 V (50)* M 2 Pipe Heat and Cool w/Aux. Elec. Heat N . Basic 24V Non-Programmable, ACO. P 2 Pipe Cool Only w/Total Elec. Heat F . Premium 24V Digital 7-Day Programmable, R 4 Pipe Heat and Cool with Proportional Fan/Valves Option, ACO. * Consult factory for 50 Hz applications. G Premium 24 Digital BACnet with ** Standing in front of the unit, hand is Proportional Fan/Valves Option, ACO. determined by looking into the air supply and assigning the hand to match the location of the cooling coil connections. International Environmental Corporation Hi-Performance Series Fan Coil Technical Catalog 6 Hi-Performance Series RATINGS AND LISTINGS. AHRI Certification C-ETL-US Listing IEC's Hi-Performance Series IEC's Vertical Series units are listed units are certified in compli- by ETL. The C-ETL-US listing signifies ance with Air-Conditioning, that IEC's fan coil units have been Heating, and Refrigeration examined by ETL and are in compli- Institute (AHRI) industry standard AHRI-440-2008 for room ance with both the and Cana- fan coil units.
10 Approved standard ratings are tabulated dian applicable standards. below. 3061627. HEATING AND COOLING EQUIPMENT. Standard Ratings Seismic Certification Cooling Capacity Power IEC's Hi-Performance Series blower coil units with seismic Unit Unit Nominal Type Coil Size CFM Total Sensible Input Watts structural upgrade option are independently tested MBH MBH PSC. 06-B 600 225. and certified in accordance with IBC-2009 and OSHPD. ICC-ES-AS-156. 08-B 800 275. HLY 10-B 1000 400. 12-B 1200 450. 14-B 1400 500. NOTES: 1. R atings are based on 80 F DB and 67 F WB EAT, 45 F. EWT, 10 F water temperature rise, high fan speed, motor voltage 115-1-60, and air flow under dry coil conditions. 2. For all application ratings, use IEC's Rating Program, or contact your local IEC representative. 3. For additional information, please consult the Directory of Certified Applied Air-Conditioning Products or AHRI's website at 4. The AHRI Standard 440 certification program does not apply to unit sizes above 1500 nominal CFM.