Specification Catalog - WaterFurnace

Specification Catalog3 Series 300A11 Geothermal heat pump2-6 ton (dual capacity) 3 SERIES 300A11 Specification CATALOGT able of ContentsModel Nomenclature .. 5 AHRI/ISO 13256-1 Performance Ratings .. 6-73 Series Design Features.. 8-10 The Aurora Control System .. 11-16 Operation Logic Data Table .. 17 Water Quality .. 17 Dimensional Data .. 18 Physical Data.. 20 Auxiliary Heat Ratings .. 21 Auxiliary Heat Electrical Data .. 21 Electrical Data .. 21 Blower Performance Data .. 22-23 Reference Calculations .. 24 Legend and Notes .. 24 Operating Limits.. 24 Antifreeze Corrections .. 25 Correction Factor Tables.. 26 Pressure Drop .. 27 Performance Data .. 28-37 Wiring Schematics .. 38 Engineering Guide Specifications .. 42-44 Revision Guide .. 4543 SERIES 300A11 Specification CATALOGThe WaterFurnace 3 Series is our newest offering and was designed to complement our 5 and 7 Series.

7 3 SERIES 300A11 SPECIFICATION CATALOG The performance standard AHRI/ASHRAE/ISO 13256-1 became effective January …

Tags:

  Catalog, Standards, Specification, Hari, Specification catalog, Ahri standard

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Advertisement

Transcription of Specification Catalog - WaterFurnace

1 Specification Catalog3 Series 300A11 Geothermal heat pump2-6 ton (dual capacity) 3 SERIES 300A11 Specification CATALOGT able of ContentsModel Nomenclature .. 5 AHRI/ISO 13256-1 Performance Ratings .. 6-73 Series Design Features.. 8-10 The Aurora Control System .. 11-16 Operation Logic Data Table .. 17 Water Quality .. 17 Dimensional Data .. 18 Physical Data.. 20 Auxiliary Heat Ratings .. 21 Auxiliary Heat Electrical Data .. 21 Electrical Data .. 21 Blower Performance Data .. 22-23 Reference Calculations .. 24 Legend and Notes .. 24 Operating Limits.. 24 Antifreeze Corrections .. 25 Correction Factor Tables.. 26 Pressure Drop .. 27 Performance Data .. 28-37 Wiring Schematics .. 38 Engineering Guide Specifications .. 42-44 Revision Guide .. 4543 SERIES 300A11 Specification CATALOGThe WaterFurnace 3 Series is our newest offering and was designed to complement our 5 and 7 Series.

2 The 3 Series benefi ts from technology that's been refi ned through 30 years of research, engineering advancements, and manufacturing experience - all at a great price point. The 3 Series 300A11 offers two-stage scroll compressors and 5-Speed ECM blowers for high effi ciency and quiet operation while our Aurora controls platform provides simple setup and diagnosis. It's our fi rst residential unit to come standard with durable all-aluminum air coils for formicary corrosion protection and our proprietary AlumiSealTM coating option for extra peace of mind. All models utilize ozone-safe R410A refrigerant to meet the most stringent EPA requirements. The 3 Series is available in fi ve dual capacity sizes (2 to 6 ton) with Copeland Scroll UltraTech compressors. 5-Speed ECM blower motors bridge the gap of high effi ciency ECM capability with great value. ECM blowers are used to increase comfort, effi ciency, and airfl ow fl exibility.

3 The Aurora Base Control (ABC) features a microprocessor control to sequence all components during operation for optimum performance. Plus, the ABC provides easy-to-use troubleshooting features with fault lights, on-board diagnostics, and a hand held Aurora Interface Diagnostic (AID) Tool. Unit confi gurations include vertical top discharge (left or right return) and horizontal units with left or right return a side or end discharge. Heavy-gauge metal cabinets are fully insulated and coated with an attractive and durable gray paint for long lasting protection. The cabinet s rounded front corners and 3 Series nameplate add a touch of elegance to the appearance. 3 Series products are performance-certifi ed to AHRI/ISO 13256-1 standards , ETL listed, ENERGY STAR qualifi ed, and tested in an ISO 17025 accredited testing lab. As a leader in the industry, WaterFurnace is dedicated to innovation, quality, and customer satisfaction.

4 In fact, every unit built is exposed to a wide range of quality control procedures throughout the assembly process and is then subjected to a rigorous battery of computerized run tests to certify that it meets or exceeds performance standards for effi ciency and safety, and will perform fl awlessly at startup. As further affi rmation of our quality standards , each unit carries our exclusive Quality Assurance emblem, signed by the fi nal test technician. WaterFurnace International s corporate headquarters ISO 9001:2008 and manufacturing facility is located in Fort Wayne, IN. A scenic three-acre pond located in front of the building serves as our geothermal heating and cooling source to comfort-condition our 110,000 square feet of manufacturing and offi ce space. As a pioneer, and now a leader in the industry, the team of WaterFurnace engineers, customer support staff, and skilled assembly technicians is dedicated to providing the fi nest comfort systems available.

5 By choosing or specifying WaterFurnace 3 Series products, you can be assured that your customer is investing in the ultimate comfort system and peace of mind for many years to Geothermal Heat Pumpoils for formicary corrosionprotection anddoururpproroprprieietatary5 3 SERIES 300A11 Specification CATALOGM odel NomenclatureL1234-6789 Model Type L 3 Series Water-to-AirCompressor Type D Dual-CapacityCabinet Configuration V Vertical H - HorizontalUnit Capacity (MBTUH) 024, 036, 048, 060, 072 Vintage * - Factory Use OnlyVoltage 1 208-230/60/1 Hot Water Generation 0 No Hot Water Generation 1 Hot Water Generation with Factory Installed PumpBlower Options 4 5 Speed ECMI ntelliStart & Air Coil Option N No IntelliStart, Uncoated Coil A IntelliStart, Uncoated Coil B No IntelliStart, AlumiSeal C IntelliStart, AlumiSealControl Option A AuroraTM Base ControlsFilter Option 2 Duct Flanges, No Filter 0 1" Filter Rack with 1" MERV 8 Filter 1 1" Filter Rails with 1" MERV 8 FilterReturn Air Configuration L Left R RightDischarge Air Configuration T Top (Vertical) S Side (Horizontal) E End (Horizontal)Water Coil Option C Copper N CuproNickelRev.

6 : 12 June 2014D10111214DV048*104 CTL213A15N1663 SERIES 300A11 Specification CATALOG5 Speed ECM motorAHRI/ASHRAE/ISO 13256-1 English (IP) UnitsModelCapacity ModulationFlow RateWater Loop Heat PumpGround Water Heat PumpGround Loop Heat PumpCoolingEWT 86 FHeating EWT 68 FCooling EWT 59 FHeating EWT 50 FCooling Brine Full Load 77 F Part Load 68 FHeating Brine Full Load 32 F Part Load 41 Fgpmcfm Capacity Btuh EER Btuh/W Capacity Btuh COP Capacity Btuh EER Btuh/W Capacity Btuh COP Capacity Btuh EER Btuh/W Capacity Btuh COP024 Full8800 22,000 28,300 25,100 23,500 23,100 18,900 16,300 20,800 18,800 17,000 18,200 14,900 33,700 42,500 38,000 35,500 35,100 26,000 25,300 30,500 28,900 25,200 27,600 21,000 46,500 53,900 52,300 45,000 49,000 36,000 34,800 39,700 39,800 32,800 38,200 28,500 57,200 69,000 64,100 56,500 59,900 45,300 43.

7 000 51,000 49,100 42,400 47,200 36,000 64,400 82,800 71,800 68,500 67,000 52,000 50,400 63,600 56,800 52,800 54,200 42,500 capacities based upon F DB, F WB entering air temperature 3/24/17 Heating capacities based upon 68 F DB, 59 F WB entering air temperatureAll ratings based upon 208V operation5 Speed ECM motorARI/ASHRAE/ISO 13256-1 Metric (SI) UnitsModelCapacity ModulationFlow RateWater Loop Heat PumpGround Water Heat PumpGround Loop Heat PumpCooling EWT 30 CHeating EWT 20 CCooling EWT 15 CHeating EWT 10 CCooling Brine Full Load 25 C Part Load 20 CHeating Brine Full Load 0 C Part Load 5 Cwater L/Sair L/S Capacity Watts EER (W/W) Capacity Watts COP Capacity Watts EER (W/W) Capacity Watts COP Capacity Watts EER (W/W)

8 Capacity Watts , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , capacities based upon 27 C DB, 19 C WB entering air temperature 3/24/17 Heating capacities based upon 20 C DB, 15 C WB entering air temperatureAll ratings based upon 208V operationcfm* = l/sgpm* = l/sin wg*249 = pascalsft of hd *2990 = pascalsEnergy Star Rating CriteriaIn order for water-source heat pumps to be Energy Star rated they must meet or exceed the minimum efficiency requirements listed below. Tier 3 represents the current minimum efficiency water source heat pumps must have in order to be Energy Start rated. Tier 3: 1/1/2012 No Effective End Date PublishedWater-to-Air EER COPG round Loop Water Loop Water Star Compliance TableModelTier 3 Ground WaterGround Loop024 YesYes036 YesYes048 YesYes060 YesYes072 YesYes7/30/14 AHRI/ISO 13256-1 Performance Ratings7 3 SERIES 300A11 Specification CATALOGThe performance standard AHRI/ASHRAE/ISO 13256-1 became effective January 1, 2000 and replaces ARI standards 320, 325, and 330.

9 This new standard has three major categories: Water Loop (comparable to ARI 320), Ground Water (ARI 325), and Ground Loop (ARI 330). Although these standards are similar there are some differences:Unit of Measure: The Cooling COPThe cooling efficiency is measured in EER (US version measured in Btu/h per Watt. The Metric version is measured in a cooling COP (Watt per Watt) similar to the traditional COP Conditions DifferencesEntering water temperatures have changed to reflect the centigrade temperature scale. For instance the water loop heating test is performed with 68 F (20 C) water rounded down from the old 70 F ( C).Air Conditions DifferencesEntering air temperatures have also changed (rounded down) to reflect the centigrade temperature scale. For instance the cooling tests are performed with F (27 C) dry bulb and F (19 C) wet bulb entering air instead of the traditional 80 F ( C) DB and 67 F ( C) WB entering air temperatures.)

10 Data may be converted to 80/67 using the entering air correction table. This represents a significantly lower relative humidity than the old 80/67 of 50% and will result in lower latent Power Correction CalculationWithin each model, only one water flow rate is specified for all three groups and pumping Watts are calculated using thefollowing formula. This additional power is added onto the existing power consumption. Pump power correction = (gpm x ) x (Press Drop x 2990) / 300 Where gpm is waterflow in gpm and Press Drop is the pressure drop through the unit heat exchanger at rated water flow in feet of Power Correction CalculationBlower power is corrected to zero external static pressure using the following equation. The nominal airflow is rated at a specific external static pressure. This effectively reduces the power consumption of the unit and increases cooling capacity but decreases heating capacity.