Example: biology

High Pressure First Stage Regulators

A15A100 RegO Dr. Elon, NC 27244 USA +1 (336) 449-7707 Ordering InformationHigh Pressure First Stage Regulators LV4403SR and TR SeriesMaterialsBody .. Die Cast ZincBonnet .. Die Cast ZincNozzle Orifice .. BrassSpring .. SteelValve Seat Disc .. Resilient RubberDiaphragm .. Integrated Fabric and Synthetic RubberPart NumberInlet ConnectionOutlet Connection Orifice SizeFactory Delivery PressureAdjustment Range* (PSIG)Integral Relief IncludedVapor Capacity BTU/hr Propane**LV4403SR4 F. NPT F. NPT 51-5Ye s2,500,000LV4403TR4105-10LV4403SR9F. POL51-5LV4403TR9105-10LV4403SR96 accurate First Stage regulation in two- Stage bulk tank systems. Reduce tank Pressure to an intermediate Pressure of 5 to 10 PSIG. Also used to supply high Pressure burners for applications like industrial furnaces or boilers.

A15 A 100 RegO Dr. Elon, NC 27244 USA www.regoproducts.com 1 336 44-7707 Ordering Information High Pressure First Stage Regulators LV4403SR and TR Series

Tags:

  First, High, Pressure, Stage, Regulators, High pressure first stage regulators

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Advertisement

Transcription of High Pressure First Stage Regulators

1 A15A100 RegO Dr. Elon, NC 27244 USA +1 (336) 449-7707 Ordering InformationHigh Pressure First Stage Regulators LV4403SR and TR SeriesMaterialsBody .. Die Cast ZincBonnet .. Die Cast ZincNozzle Orifice .. BrassSpring .. SteelValve Seat Disc .. Resilient RubberDiaphragm .. Integrated Fabric and Synthetic RubberPart NumberInlet ConnectionOutlet Connection Orifice SizeFactory Delivery PressureAdjustment Range* (PSIG)Integral Relief IncludedVapor Capacity BTU/hr Propane**LV4403SR4 F. NPT F. NPT 51-5Ye s2,500,000LV4403TR4105-10LV4403SR9F. POL51-5LV4403TR9105-10LV4403SR96 accurate First Stage regulation in two- Stage bulk tank systems. Reduce tank Pressure to an intermediate Pressure of 5 to 10 PSIG. Also used to supply high Pressure burners for applications like industrial furnaces or boilers.

2 Also incorporated in multiple cylinder Incorporate integral relief valves for added system protection. Large vent helps prevent blockage and has thread for vent piping. Bonnet vent positioned over outlet to avoid icing and contamination by foreign material. Unique bonnet vent profile designed to minimize vent freeze over when properly installed. Replaceable valve orifice and valve seat disc. Straight-line valve closure reduces wear on seat disc. Large molded diaphragm is extra sensitive to Pressure changes. Built in Pressure tap has plugged outlet. Plug can be removed with a 3 16 hex allen wrench. Extra long lever arm provides uniform delivery Pressure . Brilliant red "71 8"5 "1 "37 8"2 "3 Delivery PressurePSIG4567100200300400500600700800 90010002,500,0002,000,0001,500,0001,000, 000500,000 PSIG Inlet125 PSIG Inlet100 PSIG InletIn itial Setting50 PSIG Inlet25 PSIG Inle t10 PSIG InletLV4403 SRLV4403TR7 Delivery PressurePSIG8910111002003004005006007008 0090010002,500,0002,000,0001,500,0001,00 0,000500,000 PSIG Inlet125 PSIG Inlet100 PSIG InletIn itial Setting15 PSIG Inlet25 PSIG Inlet50 PSIG Inlet * When used for final Stage Pressure control, must either incorporate integral relief valve or separate relief valve should be specified in accordance with NFPA Pamphlet 58.

3 ** Maximum flow based on inlet Pressure 20 PSIG higher than the regulator setting and delivery Pressure 20% lower than the Series10 REGO PRODUCTS 10 YEAR WARRANTYREGO REGULATORS2525 YEAR SILVER SERVICE LIFE


Related search queries