Transcription of Low Pressure Second Stage Regulators - Standard …
1 A27A100 RegO Dr. Elon, NC 27244 USA +1 (336) 449-7707 Ordering InformationLow Pressure Second Stage Regulators - Standard SettingsLV5503B SeriesMaterialsBody (LV5503B Series .. Die Cast AluminumBonnet (LV5503B Series) .. Die Cast AluminumNozzle Orifice .. BrassSpring .. SteelValve Seat Disc .. Resilient RubberDiaphragm .. Integrated Fabric and Synthetic RubberApplicationDesigned to reduce first Stage Pressure of 5 to 20 PSIG down to burner Pressure ,normally 11 Ideal for larger commercial and industrial applications, multiple cylinder installations and large domestic Incorporates integral relief valve. With 15 PSIG inlet Pressure , regulator is designed to not pass more than 2 PSIG with the seat disc removed. Replaceable valve orifice and valve seat disc. Straight line valve closure saves wear on seat disc and orifice.)
2 Built in Pressure tap has plugged outlet. Plug can be removed with a 3 16 hex allen wrench. Large bonnet vent profile minimizes vent freeze over when properly installed. Extra long lever arm for uniform delivery Pressure . Large diaphragm is extra sensitive to Pressure SeriesPart NumberInlet ConnectionOutlet ConnectionOrifice SizeFactory Delivery PressureAdjustment RangeBonnet Vent PositionVapor Capacity BTU/hr. PropaneLV5503B4 F. NPT F. NPT 11 at 10 PSIG Inlet9 - 13 Inlet1,600,000LV5503B6 F. NPTLV5503B81 F. NPT 9/32 2,300,000 Maximum flow is based on 10 PSIG inlet and 9 delivery SERVICE LIFEA28A100 RegO Dr. Elon, NC 27244 USA +1 (336) 449-7707 Ordering InformationDielectric Low Pressure Second Stage Regulators - Standard SettingsLV5503BD SeriesMaterialsBody (LV5503BD Series .. Die Cast AluminumBonnet (LV5503BD Series).)
3 Die Cast AluminumNozzle Orifice .. BrassSpring .. SteelValve Seat Disc .. Resilient RubberDiaphragm .. Integrated Fabric and Synthetic RubberApplicationDesigned to reduce first Stage Pressure of 5 to 20 PSIG down to burner Pressure ,normally 11 Ideal for larger commercial and industrial applications, multiple cylinder installations and large domestic Dielectric Second Stage Regulators are engineered to isolate potential electrical current from metallic piping before entering a building. The use of a separate dielectric union is not necessary because the regulator contains a dielectric union as part of the inlet assembly. Available in both SAE Flare and inlet Incorporates integral relief valve. With 15 PSIG inlet Pressure , regulator is designed to not pass more than 2 PSIG with the seat disc removed.
4 Replaceable valve orifice and valve seat disc. Straight line valve closure saves wear on seat disc and orifice. Built in Pressure tap has plugged outlet. Plug can be removed with a 3 16 hex allen wrench. Large bonnet vent profile minimizes vent freeze over when properly installed. Extra long lever arm for uniform delivery Pressure . Large diaphragm is extra sensitive to Pressure SeriesPart NumberInlet ConnectionOutlet ConnectionOrifice SizeFactory Delivery PressureAdjustment RangeBonnet Vent PositionVapor Capacity BTU/hr. PropaneLV5503B4D F. NPT F. NPT 11 at 10 PSIG Inlet9 - 13 Inlet1,600,000LV5503B6D F. NPTLV5503B8D1 F. NPT 9/32 2,300,000LV5503B1D M. Flare F. NPT LV5503B5D M. FlareLV5503B16D M. FlareLV5503B48 F. NPT1 M. NPT9/32 Maximum flow is based on 10 PSIG inlet and 9 delivery SERVICE , INLETSCREEN CLEANVENTPSI10 SLMSLE/DE( ) TABLEOUTLETSEE TABLE( )( )( )( ) , INLETSCREEN CLEANVENTPSI10 SLMSLE/DE( ) TABLEOUTLETSEE TABLE( )( )( )( )