Test VOLTAGE 250V to 5kVInsulation Resistance Measurement Up to 5 TWMeasure INSULATION of high - VOLTAGE equipment (such as transformers, cables, and motors) Automatically calculate and display PI (Polarization Index) and DAR (Dielectric Absorption Ratio) Step VOLTAGE testing, temperature compensation, temperature measurement, and leakage current display Data storage and USB interfaceHIGH VOLTAGE INSULATION HiTESTERCOMPACTPERFORMANCE5 KVField Measuring Instruments3455 CAT IV 600 VPhone: 033 22350923 Fax: 033 30222923 INSULATION Tester Digital 5KV INSULATION tester 5000 volts INSULATION Resistance Tester Hioki 3455 5000 volts 2500 volts 1000 volts 500 volts INSULATION tester Digital Megger Digital INSULATION tester with memory PI polarisation index DAR Dielectric absorbtion ratio test VOLTAGE elapsed time 10 minutes 1 minute 30 seconds 15 seconds usb interface computer communication auto discharge self discharge 10 giga ohms 100 gigaohms 1000 giga ohms 5 teraohms 5 Tohms tera ohms auto power off INSULATION tester 5000 volts dc INSULATION resistance tester Japanese 5kv INSULATION tester HIOKI 3455 Best INSULATION tester low cost b

3 Response time: n Leakage Current Measurement range: Current range and accuracy: Response time: n Voltage Measurement range: Frequency: Accuracy: Input impedance: Response time:

Tags:

  High, Ranges, Current, Voltage, High voltage insulation hitester, Insulation, Hitester, Current range

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of HIGH VOLTAGE INSULATION HiTESTER - …

1 Test VOLTAGE 250V to 5kVInsulation Resistance Measurement Up to 5 TWMeasure INSULATION of high - VOLTAGE equipment (such as transformers, cables, and motors) Automatically calculate and display PI (Polarization Index) and DAR (Dielectric Absorption Ratio) Step VOLTAGE testing, temperature compensation, temperature measurement, and leakage current display Data storage and USB interfaceHIGH VOLTAGE INSULATION HiTESTERCOMPACTPERFORMANCE5 KVField Measuring Instruments3455 CAT IV 600 VPhone: 033 22350923 Fax: 033 30222923 INSULATION Tester Digital 5KV INSULATION tester 5000 volts INSULATION Resistance Tester Hioki 3455 5000 volts 2500 volts 1000 volts 500 volts INSULATION tester Digital Megger Digital INSULATION tester with memory PI polarisation index DAR Dielectric absorbtion ratio test VOLTAGE elapsed time 10 minutes 1 minute 30 seconds 15 seconds usb interface computer communication auto discharge self discharge 10 giga ohms 100 gigaohms 1000 giga ohms 5 teraohms 5 Tohms tera ohms auto power off INSULATION tester 5000 volts dc INSULATION resistance tester Japanese 5kv INSULATION tester HIOKI 3455 Best INSULATION tester low cost best price INSULATION resistance tester 5KV INSULATION tester with self discharge auto discharge safe to use Hioki 3455 available in

2 INDIA2n FeaturesGenerate Test Voltages Across a Wide Spectrum The 3455 can generate test voltages ranging from 250 V to 5 kV. Settings can be made in steps as fi ne as 25 V. Very high INSULATION resistance measurement up to 5 teraohms is for All INSULATION Diagnostic ApplicationsFunctions such as automatic calculation and display of PI (Polarization Index) and DAR (Dielectric Absorption Ratio), as well as step VOLTAGE test, temperature compensation, temperature measurement, and leakage current display make the 3455 suitable for a variety of diagnostic Memory FunctionThe 3455 provides a manual storage function for 100 data and a logging function for 10 data (360 times). The date and time of measurement are also InterfaceEasily transfer data to a PC via the USB interface using our free PC application software.

3 The software also features a convenient report creation ForemostThe 3455 complies with FeaturesFeaturesGenerate Test Voltages Across a Wide Spectrum Generate Test Voltages Across a Wide Spectrum safety regulations for category IV measurements (600 V). A shutter mechanism prevents simultaneous use of measurement terminals and other terminals. Other safety features include a VOLTAGE measurement function, high - VOLTAGE warning indicator, and auto discharge , Easy to Read DisplayThe display is backlit and features a logarithmic bar graph as an analog type indicator in addition to the digital Range Test VOLTAGE SettingsActual output VOLTAGE > fl ashes if measurement range was exceededz INSULATION resistance measurementMeasurement VOLTAGE is selectable from 250 V, 500 V, kV, kV, and kV.

4 More fi nely graded settings are also possible. When measurement is completed, the unit shows the INSULATION resistance value, test VOLTAGE (setting and actual output), leakage current , DAR, PI, and elapsed Leakage current displayWhen measuring INSULATION resistance, the instrument can be switched to display leakage current . This is possible before, during, and after time INSULATION resistance valueInsulation resistance measurement displayz Step VOLTAGE testIn this type of test, the VOLTAGE is gradually raised and the INSULATION resistance and leakage current change is measured. Two different step settings are available: 500 V 1 kV kV 2 kV kV and 1 kV 2 kV 3 kV 4 kV 5 kV. The test time for each step can also be Step2 Step3 Step4 Step55kV4kV3kV2kV1kVMeasurementcompleted 1 2 3 4 5 minutesn Primary Measurement FunctionsSTEP kV step VOLTAGE testDisplay of leakage current during measurement Actual output voltageInsulation resistance value > fl ashes if less than 1 nAElapsed time leakage current value3 Response time:n Leakage current Measurement range: current range and accuracy:Response time:n VOLTAGE Measurement range: Frequency: Accuracy:Input impedance: Response time:n Temperature Measurement rangeand Accuracy: Response time:15s max.

5 (from measurement start to until guaranteed accuracy display, no averaging)( current measurement with test VOLTAGE being generated) to s max. (from measurement start to until guaranteed accuracy display, no averaging)(temperature and humidity range for guaranteed accuracy 23 5 C, max. 90%rh, no condensation)DC 50V to , AC 50V to 750 VDC/ 50Hz/ 60Hz 5%rdg. 5dgt. (for DC, absolute values of kV and above are out of guaranteed accuracy range)Approx. 10 MW 3 s or lessWhen using the temperature sensor 9631-05, accuracy is guaranteed only for - C rangeApprox. 100 s, including response of temperature sensor models 9631-01 to 9631-05(reference value, time until a 90% value of a temperature change is shown) current rangeMeasurement to 15%rdg. 1nA100nA to 15%rdg.

6 90nA to 999nA A to A A A to A A to 999 A, to 5dgt.(auto range, temperature and humidity range for guaranteed accuracy 0 to 28 C, max. 90%rh, no condensation)Measurement rangeAccuracy C to C C to C C to C Cn Measurement Items:n INSULATION ResistanceTest VOLTAGE :Setting:Measurement current : Short-circuit current : Output voltageMonitor function: Measurement range:Resistance range: (auto range) INSULATION resistance, leakage current , VOLTAGE , temperature 250V to DCPreset test voltages: 250 V, 500 V, 1 kV, kV, 5 kVFine adjustment: possible in 25 V steps between 250 V and 1 kV and in 100 V steps between 1 and 5 kVApplies only when the measured resistance is equal to or higher than the value gained from dividing the test VOLTAGE (setting VOLTAGE ) by the rated measurement current .

7 Output VOLTAGE is not guaranteed if measured resistance is lower than [test VOLTAGE /rated measurement current ].Rated measurement current tolerance: -0%, +10%2 mA or less Display range: 0 to 999 V, to kVMonitor accuracy: 5% rdg. 5 rangeAccuracyUp to [Test VOLTAGE / Resistance measurable at 100 nA] 5%rdg. 5dgt.[Test VOLTAGE / Resistance measurable at 100 nA] to 500 GW 20%rdg. to 30%rdg. rangeMeasurement to to 90MW to 999MW10GW to to 90GW to to voltageMeasurement range250 to 250GW500 to 500GW1 to to to voltageMeasurement current250V to to to (temperature and humidity range for guaranteed accuracy 0 to 28 C, max. 90%rh, no condensation)250V 500V 1kV 500G 250G 100G 100M 30%rdg.

8 50dgt. 20%rdg. 5dgt. 5%rdg. Complete Diagnostic Tests of Transformers, Cables, Motors and Other Equipment n Specifications Accuracy:Resistance range accuracyz PI and DAR displayPI: Polarization Index DAR: Dielectric Absorption RatioThe PI and DAR values which are used as an evaluation standard for INSULATION are automatically calculated. With the INSULATION resistance measurement start point as reference, the calculation is performed as follows, using two resistance values obtained at a prescribed time interval. resistance value 10 min after start Formulas : PI= resistance value 1 min after start resistance value 1 min after start DAR 1min/15s = resistance value 15 sec after start resistance value 1 min after start DAR 1min/30s = resistance value 30 sec after start Measurement timeRight: first measurement Left: second measurementDAR valueResistance valueRight: first measurement valueLeft: second measurement valueMeasurement timeFirst : 1 min ; Second : 10 minPI valueResistance valueRight: first measurement GWLeft: second measurement GWInsulation resistanceTest VOLTAGE (setting value)4 All information correct as of Jul.

9 13, 2009. All specifications are subject to change without Printed in Japann INSULATION DiagnosisTemperature compensation:PI/DAR display:Step VOLTAGE test:n Supplementary FunctionsData memory:Communication:Other items:Result converted to INSULATION resistance at reference temperature. 10 different temperature compensation tables can be selected, according to INSULATION material of measurement object. Reference temperature: 20 C or 40 C by default, setting can be : Polarization IndexDAR: Dielectric Absorption RatioAfter INSULATION resistance measurement has started, calculation is performed using two resistance values obtained at prescribed time of INSULATION resistance while raising VOLTAGE at specific intervals. Two VOLTAGE step patterns can be : 500V 1kV 2kV 5kV : 1kV 2kV 3kV 4kV 5kVVoltage application time for each step: 30 recording: store up to 100 data , Data type: standard measurement data/ temperature compensation data/step VOLTAGE test data, Data logging: store measurement value at preset intervals, available for INSULATION resistance measurement only, Number of data: 10, Number of logging instances: 360 times per data, Recording interval: 15/30 s /1/2/5m, Data content: date, time, measurement interval, temperature, set VOLTAGE , actual output VOLTAGE times, resistance times, Additional functions: write mode, read mode, all clear, selective clear, overwriteInterface: USB ver (full speed) PC application software.

10 Transfer of memory data from 3455 to computer, data display, create graph,3455 items that can be set/changed from computer: date, time, PI time, step time for step VOLTAGE test, report functionTemperature/humidity value input, timer, elapsed time display, clock, averaging, data hold, auto discharge, active VOLTAGE warning indication, hot conductor warning indication, LCD backlight, auto power-off, buzzern General SpecificationsOperating temp. , humidity:Storage temp. , humidity:Guaranteed accuracy period:Operating environment:Measurement method:A/D conversion:Display:Indication:Display update rate:Power supply:Max. power consumption:Continuous operation time: (reference value)Max. input VOLTAGE to ground:Withstand VOLTAGE :Dimensions & Mass:Applicable standards:Accessories:Options:0 to 40 C, max90%rh (no condensation)10 to 40 C, max.