1 SURFACE MOUNT GENERAL RECTIFIERREVERSE VOLTAGE50 to 1000 Volts FORWARD AmpereFEATURESThe plastic package carries Underwriters LaboratoryFlammability Classification 94V-0 For surface mounted applicationsLow reverse leakageBuilt-in strain relief, ideal for automated placementHigh forward surge current capabilityHigh temperature soldering guaranteed:250 C/10 secondsat terminalsMECHANICAL DATACase: JEDEC DO-214AC molded plastic bodyTerminals: Plated axial leads, solderable per MIL-STD-750,Method 2026 Polarity: Color band denotes cathode endMounting position: AnyMAXIMUM RATINGS AND ELECTRICALCHARACTERISTICSR atings at 25 C ambient temperature unless otherwise specified ,Single phase, half wave, 60Hz, resistive or inductive capacitive load derate current by 20%PARAMETERSYMBOLM1M2M3M4M5M6M7 UNITM aximum Repetitive Peak Reverse VoltageVRRM 501002004006008001000 VOLTSM aximum RMS VoltageVRMS 3570140280420560700 VOLTSM aximum DC Blocking VoltageVDC501002004006008001000 VOLTSM aximum average forward rectified currentat TL= 55 CI(AV) Forward Surge Current single half sine-wave superimposedon rated load (JEDEC Method) instantaneous forward voltage at DC Reverse Current TA= 25 Cat Rated DC blocking voltage TA = 100 Typical Junction Capacitance (Note 1) Thermal Resistance (Note 2)R C/WOperating junction and Storage temperature rangeTJ,TSTG-55 to +150 C1-Measured at 1 MHz and appli

1 SURFACE MOUNT GENERAL RECTIFIER REVERSE VOLTAGE50 to 1000 Volts FORWARD CURRENT1.0 Ampere FEATURES The plastic package carries Underwriters Laboratory Flammability Classification 94V-0

Tags:

  Ruth, 1000, Volt, M1 thru m7, To 1000 volts

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of M1 THRU M7 - Kingtronics

1 1 SURFACE MOUNT GENERAL RECTIFIERREVERSE VOLTAGE50 to 1000 Volts FORWARD AmpereFEATURESThe plastic package carries Underwriters LaboratoryFlammability Classification 94V-0 For surface mounted applicationsLow reverse leakageBuilt-in strain relief, ideal for automated placementHigh forward surge current capabilityHigh temperature soldering guaranteed:250 C/10 secondsat terminalsMECHANICAL DATACase: JEDEC DO-214AC molded plastic bodyTerminals: Plated axial leads, solderable per MIL-STD-750,Method 2026 Polarity: Color band denotes cathode endMounting position: AnyMAXIMUM RATINGS AND ELECTRICALCHARACTERISTICSR atings at 25 C ambient temperature unless otherwise specified ,Single phase, half wave, 60Hz, resistive or inductive capacitive load derate current by 20%PARAMETERSYMBOLM1M2M3M4M5M6M7 UNITM aximum Repetitive Peak Reverse VoltageVRRM 501002004006008001000 VOLTSM aximum RMS VoltageVRMS 3570140280420560700 VOLTSM aximum DC Blocking VoltageVDC501002004006008001000 VOLTSM aximum average forward rectified currentat TL= 55 CI(AV) Forward Surge Current single half sine-wave superimposedon rated load (JEDEC Method) instantaneous forward voltage at DC Reverse Current TA= 25 Cat Rated DC blocking voltage TA = 100 Typical Junction Capacitance (Note 1) Thermal Resistance (Note 2)R C/WOperating junction and Storage temperature rangeTJ,TSTG-55 to +150 C1-Measured at 1 MHz and applied reverse voltage of mounted with ( ) copper pad areasM1 THRU M7DO-214 ACWebsite.

2 Email: Tel: (852) 8106 7033 Fax: (852) 8106 7099 Dimensions in inches and (millimeters)2 RATINGS AND CHARACTERISTIC CURVESNote: Specifications are subject to change without THRU M7 Website: Email: Tel: (852) 8106 7033 Fax: (852) 8106 7099


Related search queries