Example: bankruptcy

Hinging / Latching Frame/Optical Shielding …

Metalux Safe and convenient means of disconnecting power24 FRLED2' X 4' LED LUMINAIREP remium Recessed Commercial LED LuminaireFor Use in Insulated CeilingsThe FR series is a premium recessed commercial luminaire which offers a high quality lighting solution dedicated with the latest solid state lighting and electronic driver technology for optimal performance and energy efficiency. The FR series is compatible with all of today s popular ceiling systems and is available with a number of Shielding options and accessories for application FR series features efficiency, quality and performance. The series is an excellent choice for commercial office spaces, schools, hospitals or retail merchandising FEATURESC onstructionRigid housing is die formed of code gauge prime cold rolled steel and features full length die-formed stiffeners and unibody endplate for added strength.

c Eaton 112 a 4 Peac y 2 440 www.eaton.com/lighting 24FR PS519053EN May 31, 2018 9:50 AM PHOTOMETRICS 24FR-LD4-40-UNV-L835-CD1-U …

Tags:

  Lighting

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of Hinging / Latching Frame/Optical Shielding …

1 Metalux Safe and convenient means of disconnecting power24 FRLED2' X 4' LED LUMINAIREP remium Recessed Commercial LED LuminaireFor Use in Insulated CeilingsThe FR series is a premium recessed commercial luminaire which offers a high quality lighting solution dedicated with the latest solid state lighting and electronic driver technology for optimal performance and energy efficiency. The FR series is compatible with all of today s popular ceiling systems and is available with a number of Shielding options and accessories for application FR series features efficiency, quality and performance. The series is an excellent choice for commercial office spaces, schools, hospitals or retail merchandising FEATURESC onstructionRigid housing is die formed of code gauge prime cold rolled steel and features full length die-formed stiffeners and unibody endplate for added strength.

2 Side flanges are hemmed. Innovative design provides superior lens brightness uniformity and visual comfort. Unibody endplates are securely attached with interlocking tabs and screws. Four auxiliary fixture end suspension points provided. Endplates have integral Grid-lock feature for safety and LED luminaires come standard with 0-10V dimming driver (10% standard, 1% optional). Options compatible with Eaton s Connected lighting Systems: WaveLinx sensor LumaWatt Pro sensor SVPD sensor DLVP sensor and driver Fifth Light DALI driverOther options include step-dimming and 3rd party drivers. Refer to the Connected lighting options page and ordering information for more LED system coupled with electrical driver to deliver optimal performance.

3 LED s available in 2700K, 3000K, 3500K, 4000K or 5000K with min. 80 CRI. Rated life based on TM21 is greater than L82 at 60,000 hours. Electronic drivers are available for 120-277V applications. A 0-10V dimming driver is Battery Pack OptionOptional 120V-277V integral emergency battery pack is available in 7-watts or 14-watts to meet critical life-safety lighting requirements. The 90-minute batteries provide constant power to the LED system, ensuring code-compliance. A test switch/indicator button can be tested safely from the ground using a laser pointer, while the patented EZ Key prevents accidental discharge of the battery during construction. Emergency/generator transfer options available see ordering information for , iron phosphate pretreatment ensures maximum bonding and rust inhibition.

4 Housing and driver cover finished with new 90% reflective white enamel for superior / LatchingCam steel latches with baked white enamel finish. Safety-lock T-hinges allow Hinging and Latching from either ShieldingCurved, Frost lens within steel hinged door frame. Lens offers a balance of aesthetics and light luminaires are cULus listed for 25 C ambient environments. Fixtures are suitable for direct insulation contact and are damp location listed. RoHS compliant. LED components comply with IESNA LM-79 and LM-80 standards. DesignLights Consortium Qualified and classified for both DLC Standard and DLC Premium, refer to for details. Can be used for State of California Title 24 high efficacy 31, 2018 9:50 AM23-3/4" [603mm]3-1/4"[83mm]23-3/4"[603mm]47-3/4" [1212mm]47-15/16" [1218mm]MOUNTING DATAC eilingTrimTypeTypeExposed GridGConcealed TGSlot GridG(Verify compatibility/ consultfactory.)

5 GGrid/Lay-inStandardGConcealed TGSlot GridCEILING COMPATIBILITYC alifornia Title 24 Non-ResidentialCompliantCatalog #ProjectCommentsPrepared byTypeDateSpecifications and dimensions subject to change without 1121 Highway 74 SouthPeachtree City, GA 30269P: NumberShielding TypeNominalLumensWattageEfficacy(lm/W @ 3500K) 1 7. 0 Notes: All models also available in 2700K, 3000K, 3500K, 4000K, and based on 3500K. Use lumen multiplier for other performance Color Temperature TABLEPS519053 ENMay 31, 2018 9:50 AMSpecifications and dimensions subject to change without 1121 Highway 74 SouthPeachtree City, GA 30269P: 31, 2018 9:50 AMPHOTOMETRICS24FR-LD4-40-UNV-L835-CD1-U Electronic DriverLinear LED 4000 KSpacing criterion: (II) x mounting height, ( ) x mounting heightLumens: 3991 Input Watts: : lm/WTest Report.

6 II45 Across 1493 1493 14931487 1480 14891461 1456 14671418 1417 14291356 1363 13761281 1294 13161193 1212 12371097 1121 1152994 1021 1053886 918 951769 811 844661 700 731546 588 618438 477 508335 367 390235 259 276140 157 16858 67 660 0 0 Coefficients of UtilizationEffective floor cavity reflectance 20%rc80%70%50%30%10%0%rw7050301070503010 503010503010503010 0 RCR012345678910119 119 119 119 116 116 116 116 111 111 111 106 106 106 102 102 102 100109 104 100 96 106 102 98 94 98 94 91 94 91 89 90 88 86 8499 91 84 78 96 89 83 77 85 80 76 82 78 74 79 75 72 7090 80 72 65 88 78 71 65 75 69 64 73 67 62 70 65 61 5983 71 62 55 81 70 61 55 67 60 54 65 59 54 63 57 53 5176 63 54 48 74 62 54 48 60 53 47 58 52 47 56 51 46 4470 57 48 42 69 56 48 42 54 47 41 53 46 41 51 45 41 3965 52 43 37 64 51 43 37 50 42 37 48 41 36 47 41 36 3461 47 39 33 59 47 39 33 45 38 33 44 37 33 43 37 32 3057 44 35

7 30 55 43 35 30 42 35 30 41 34 29 40 34 29 2753 40 32 27 52 40 32 27 39 32 27 38 31 27 37 31 27 25 Zonal Lumen SummaryZoneLumens% Fixture0-300-400-600-900-1801139 DriverLinear LED 3500 KSpacing criterion: (II) x mounting height, ( ) x mounting heightLumens: 6543 Input : lm/WTest Report: 24FR-LD4-65-UNV-L835-CD1-U05101520253035 4045505560657075808590 CandlepowerAngleAlong II45 Across 2446 2446 24462436 2424 24382391 2384 24002321 2322 23392221 2231 22552099 2118 21511953 1988 20261793 1836 18841625 1674 17261447 1507 15651261 1332 13831075 1152 1198895 964 1014717 783 825546 599 636381 429 453231 260 28199 110 1060 0 0 Coefficients of UtilizationEffective floor cavity reflectance 20%rc80%70%50%30%10%0%rw7050301070503010 503010503010503010 0 RCR012345678910119 119 119 119 116 116 116 116 111 111 111 106 106 106 102 102 102 100109 104 100 96 106 102 98 94 98 94 91

8 94 91 89 90 88 86 8499 91 84 78 96 89 83 77 85 80 76 82 78 74 79 75 72 7090 80 72 65 88 78 71 65 75 69 64 73 67 62 70 65 61 5983 71 62 55 81 70 61 55 67 60 54 65 59 54 63 57 53 5176 63 54 48 74 62 54 48 60 53 47 58 52 47 56 51 46 4470 57 48 42 69 56 48 42 54 47 41 53 46 41 51 45 41 3865 52 43 37 64 51 43 37 50 42 37 48 41 36 47 41 36 3461 47 39 33 59 47 39 33 45 38 33 44 37 33 43 37 32 3057 44 35 30 55 43 35 30 42 35 30 41 34 29 40 34 29 2753 40 32 27 52 40 32 27 39 32 27 38 31 27 37 31 27 25 Zonal Lumen SummaryZoneLumens% Fixture0-300-400-600-900-1801866 30 40 50 70 90 20 80 60 12241836244810 3740 30 40 50 70 90 20 80 60 7481121149510 Luminance DataAnglein DegAverage0-Degcd/smAverage45-Degcd/smAv erage90-Degcd/sm45556575851919 1988 20601765 1869

9 1952 1587 1729 1841 1391 1533 1633 1019 1177 1160 Luminance DataAnglein DegAverage0-Degcd/smAverage45-Degcd/smAv erage90-Degcd/sm45556575853134 3264 33902871 3076 31992599 2838 29902255 2539 26811740 1933 1863 Specifications and dimensions subject to change without 1121 Highway 74 SouthPeachtree City, GA 30269P: NUMBER: 24FR-LD4-40-UNV-L835-CD1-UNOTES: (1)An EQ Grid Clip is recommended for all 9/16" ceiling systems. Four required per fixture. (2) Products also available in non-US voltages and frequencies for international markets.

10 (3) External test switch / indicator / laser test. For approximate delivered lumens multiply the lumens per watt of the desired fixture by the wattage of the emergency battery pack (100 lm/W x 7=700 lumens). IES-format photometry for luminaire under emergency operation available. (4) Nominal lumen output. (5)Must be used in conjunction with a DALI control system. For complete DALI soluitions by Fifth Light, visit (6)Used to bypass local control during outage. Must be used in conjunction with UL 1008 device (provided by others). GTR2 and ETR2 options include 2 relays on fixtures with dimming drivers. ETRD option only requires one relay when used on a dimming fixture. Must specify voltage as 120V or 277V when ordering these devices.


Related search queries