Example: quiz answers

HS35 Incremental Optical Encoder - BEI Sensors

hs35 Incremental Optical Encoder Mechanical Specifications The hs35 com- Shaft Bore: , , , , . All are supplied with insulating sleeves. bines the rug- Allowable Misalignment: on mating shaft from shaft end ged, heavy-duty Bore Runout: maximum features usually Starting Torque at 25 C: Through shaft version (SS) = 7 in-oz (max);. Blind shaft version (BS) = 4 in-oz (max). associated with Bearings: 52100 SAE High carbon steel shafted encod- Shaft Material: 416 stainless steel Bearing Housing: Die cast aluminum with protective finish ers into a hollow Cover: Die cast aluminum with protective finish shaft style.

Tel: 805-968-0782 /800-350-2727 | Fax: 805-968-3154 /800-960-2726 7230 Hollister Ave., Goleta, CA 93117-2807 | www.beisensors.com These commodities, technology or ...

Tags:

  Optical, Encoder, Incremental, Hs35 incremental optical encoder, Hs35

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of HS35 Incremental Optical Encoder - BEI Sensors

1 hs35 Incremental Optical Encoder Mechanical Specifications The hs35 com- Shaft Bore: , , , , . All are supplied with insulating sleeves. bines the rug- Allowable Misalignment: on mating shaft from shaft end ged, heavy-duty Bore Runout: maximum features usually Starting Torque at 25 C: Through shaft version (SS) = 7 in-oz (max);. Blind shaft version (BS) = 4 in-oz (max). associated with Bearings: 52100 SAE High carbon steel shafted encod- Shaft Material: 416 stainless steel Bearing Housing: Die cast aluminum with protective finish ers into a hollow Cover: Die cast aluminum with protective finish shaft style.

2 Its Bearing Life: X 109 revs (50,000 hrs at 2500 RPM). design includes Maximum RPM: 6,000 RPM (see Frequency Response below). Moment of Inertia: oz-in-sec2. dual bearings Weight: 18 oz typical and shaft seals Electrical Specifications for NEMA 4, 13 and Code: Incremental IP65 environmental Output Format: 2 channels in quadrature, 1/2 cycle index gated with negative B channel Cycles Per Shaft Turn: 1 to 80,000 (see table A). ratings, a rugged metal For resolutions above 5000 see interpolation options in Table A. housing, and a sealed connector or Supply Voltage: 5 to 28 VDC available (see note 5). cable gland.

3 The hs35 accommodates Current Requirements: 100 mA typical + output load, 250 mA (max). Voltage/Output: (see note 5). shafts up to 1 in diameter. With optional 28V/V: Line Driver, 5 28 VDC in, Vout = Vin insulating inserts, it can be mounted 28V/5: Line Driver, 5 28 VDC in, Vout = 5 VDC. 28V/OC: Open Collector, 5 28 VDC in, OCout on smaller diameter shafts. It can be The hs35 Dual Output Encoder Protection Level: Reverse, overvoltage and output short circuit (See note 5). mounted on a through shaft or a blind Frequency Response: 150 kHz (up to 5000 cpt resolution; 300 KHz above 5000. shaft with a closed cover to maintain its environmental rating.)

4 The hs35 is also cpt, also see note 7). Output Terminations: See table 1 page 65. available with a dual output option (inset) to provide redundant Encoder signals, Note: Consult factory for other electrical options dual resolutions, or to supply two separate controllers from a single Encoder . Environmental Specifications Applications include motor feedback and vector control, printing industries, Enclosure Rating: NEMA 4 & 13 (IP65) when ordered with shaft seal (on units robotic control, oil service industries, and web process control. with an MS connector) or a cable gland (on units with cable termination).

5 Special Models of the hs35 Incremental Encoder are available with one or more of the Temperature: Operating, 0 to 70 C; extended temperature testing up to 105 C. available (see note 8); Storage, -25 to following certifications. Consult factory for details. 90 C unless extended temperature option called out Standards Class I, CENELEC Shock: 50 g's for 11 msec duration EN 55011 and EN 61000-6-2 Group A,B,C II 1 G Ex ia IIB/IIC T4 Ga Vibration: 5 to 2000 Hz @ 20 g's Class II Group E, F & G II 3 G Ex nA IIB T3 Gc Humidity: 98% RH without condensation Class I, Div 2, Group A,B,C Canadian Standards UL NOTES & TABLES: All notes and tables referred to in the text can be found on the Class II, Div 2, Group F & G C Class I, Zone 0, Group IIC back of this page.

6 UL hs35 Incremental Ordering Options FOR ASSISTANCE CALL 800-350-2727. Use this diagram, working from left to right to construct your model number (example: HS35F-100- R1-SS-2048-ABZC-28V/V-SM18). All notes and tables referred to can be found on the back of this page. hs35 . TYPE: SHAFT BORE: CYCLES PER TURN: COMPLEMENTS: TETHER: (Enter Cycles) HAZARDOUS. HS = Hollow Shaft 100 = R1 = Tether Block and Pin C = Complementary AREA RATINGS: 35 = Encoder 87 = R2 = Tether Arm See table A on back page Outputs X= Blank = None Diameter 75 = Blank = None See note 4 EX = Intrinsically Safe Express NO. OF CHANNELS: Encoder 62 = NI = Non-Incendive HOUSING 50 = etc.

7 ABZ See note 3. Contact factory for SPECIAL FEATURES: CONFIG: Metric bores available SHAFT SEAL voltage options S = Special F = Standard CONFIGURATION: VOLTAGE/OUTPUT: features specified SS =Through Shaft Rubber Seals 28V/V = 5 28 Vin/out on purchase order BS = Blind Shaft Rubber Seal 28V/5 = 5 28 Vin/5 Vout OUTPUT TERMINATION: EXPRESS ENCODERS FS = Through Shaft Felt Seals 28V/OC = 5 28 Vin/OCout SM12 = MS3112E12-10P, M16 = MS3102R16S-1P (consult factory). Items highlighted with are standard Express BFS = Blind Shaft Felt Seal SM18 = MS3102R18-1P See note 6. See note 5. Encoders and ship in one to three days.

8 See Note 2 (Indicate S for single or D for Dual ( DM18 = Dual). SCS = Shielded, Jacketed Cable with cable gland seal and T2 option is available as a standard hs35 Express Encoder . cable length in inches. ( SCS18 = 18 inches). TB = Terminal Block (See table 1 & note 9). Tel: 805-968-0782 /800-350-2727 | Fax: 805-968-3154 / 800-960-2726. 7230 Hollister Ave., Goleta, CA 93117-2807 | Specification No. 02063-001 Rev. 7-14. These commodities, technology or software if exported from the United States must be in accordance with the Bureau of Industry, and Security, Export Administration regulations. Diversion contrary to law is prohibited.)

9 hs35 Incremental Optical Encoder Dimensions MS Connector Termination R1 Tether Block and Pin R2 Tether Arm Dual Output Cable Termination Table 1 Figure 1 Notes Incremental Output 1. The typical hollow shaft product is supported by, and 28V/OC: NPN Open Collector (3904*, 7273*). Current M18 CONNECTOR M12 CONNECTOR. Output Waveform clamped to, the driving shaft. A flexible tether is used to sink of 80 mA max. Current sourced by external pull- up Terminations PIN CHANNEL PIN CHANNEL. 1 CYCLE. keep the housing from rotating. resistor. Output can be pulled up to voltage other than A A A A supply voltage (30 V max).

10 Input voltage 5 to 28 VDC. The connector style rubber shaft seal is recommended in virtually all B B B B 90 Deg. +/- 5% standard. Supply current is 120 mA typical. This installations. The most common exceptions are applica- will determine pinouts. C Z C Z HI tions requiring a very low starting torque or those requiring replaces prior IC's with designations of 3904, 7406, D +V D +V operation at both high temperature and high speed. For 3302, 681 and 689. 5V/OCR, 15V/OCR, 24V/OCR: For example, an encod- E E . A LO. Open Collector (3904R*, 7406R*, 7273R*): Current these exceptions, a felt shaft seal is recommended.