Example: quiz answers

Human Inflammatory Cytokine Standards - pufei.com

BD cytometric Bead array (CBA)Technical Data SheetHuman Inflammatory Cytokine StandardsProduct InformationMaterial Number:552932 Size: ml lyophilizedLyophilized in an aqueous buffered solution containing BSA and ProClin Buffer:DescriptionThe Human Inflammatory Cytokine Standards contain a lyophilized mixture of recombinant Human Interleukin (IL)-8, IL-1 , IL-6, IL-10, Tumor Necrosis Factor (TNF), and IL-12p70. The reconstituted Human Inflammatory Cytokine Standards are useful as a standard control with the BD cytometric Bead array (CBA) Human Inflammatory Cytokine Kit (Cat.)

the BD Cytometric Bead Array (CBA) Human Inflammatory Cytokine Kit (Cat. No. 551811). Please refer to the manual included with the BD Please refer to the manual included with the BD CBA Human Inflammatory Cytokine Kit for further information.

Tags:

  Array, Standards, Human, Inflammatory, Beads, Bd cytometric bead array, Cytometric, Cytokine, Human inflammatory cytokine standards

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of Human Inflammatory Cytokine Standards - pufei.com

1 BD cytometric Bead array (CBA)Technical Data SheetHuman Inflammatory Cytokine StandardsProduct InformationMaterial Number:552932 Size: ml lyophilizedLyophilized in an aqueous buffered solution containing BSA and ProClin Buffer:DescriptionThe Human Inflammatory Cytokine Standards contain a lyophilized mixture of recombinant Human Interleukin (IL)-8, IL-1 , IL-6, IL-10, Tumor Necrosis Factor (TNF), and IL-12p70. The reconstituted Human Inflammatory Cytokine Standards are useful as a standard control with the BD cytometric Bead array (CBA) Human Inflammatory Cytokine Kit (Cat.)

2 No. 551811). Please refer to the manual included with the BD CBA Human Inflammatory Cytokine Kit for further information. Preparation and StorageStore undiluted at 4 Human Inflammatory Cytokine Standards were mixed at a concentration of 50 ng of each protein/ml and lyophilized under optimal conditions. Following reconstitution, store the freshly reconstituted standard at 4 C and use within 12 of Human Inflammatory Cytokine Standard DilutionsApplication NotesRecommended Assay Procedure: The Human Inflammatory Cytokine Standards have been tested with the BD CBA Human Inflammatory Cytokine Kit to assure protein amounts and function in the BD CBA assay.

3 The lyophilized Standards should be reconstituted using the Assay Diluent (Cat. No. 51-2432KC) supplied in the BD CBA Human Inflammatory Cytokine Kit. Refer to the Preparation of Human Inflammatory Cytokine Standards on this sheet or in Section 6 of the BD CBA Human Inflammatory Cytokine Kit (Cat. No. 551811) : Preparation of Human Inflammatory Cytokine Standards : The Human Inflammatory Cytokine Standards are lyophilized and should be reconstituted and serially diluted before mixing with the Capture beads and the PE Detection Reagent.

4 1. Reconstitute 1 vial of lypholized Human Inflammatory Cytokine Standards with ml of Assay Diluent to prepare a 10x bulk standard. Allow the reconstituted standard to equilibrate for at least 15 minutes before making dilutions. Agitate vial to mix thoroughly. Do not vortex, mix by pipet Label 12 x 75 mm tubes (BD Falcon, Cat. No. 352008) and arrange them in the following order: Top Standard, 1:2, 1:4, 1:8, 1:16, 1:32, 1:64, 1:128, and 1:256. 3. Add 900 l of Assay Diluent to the Top Standard tube.

5 4. Add 300 l of Assay Diluent to each of the remaining tubes. 5. Transfer 100 l of 10x bulk standard to the Top Standard tube and mix Rev. 1 Page 1 of 26. Perform a serial dilution by transferring 300 l from the Top Standard to the 1:2 dilution tube and mix thoroughly. Do not vortex, mix by pipet only. Continue making serial dilutions by transferring 300 l from the 1:2 tube to the 1:4 tube and so on to the 1:256 tube and mix thoroughly. The Assay Diluent serves as the negative approximate concentration (pg/ml) of recombinant protein in each dilution tube is shown in Figure Inflammatory Cytokine Standard Concentrations after DilutionProduct NoticesSince applications vary, each investigator should titrate the reagent to obtain optimal results.

6 1. Please refer to for technical protocols. 2. Source of all serum proteins is from USDA inspected abattoirs located in the United States. 3. ProClin is a trademark of Rohm and Haas Company. 4. Hazardous Ingredient: ProClin 150. Avoid exposure to skin and eyes and ingestion. Wash exposed skin with soap and water. Flush eyes with water. 5. 552932 Rev. 1 Page 2 of 2