Transcription of I-210+c SmartMeter - Itron, Inc.
1 I-210+c . SmartMeter Itron's residential smart metering solution features a communications module that is integrated into the GE. I-210+c electricity meter. The I-210+c SmartMeter communicates over an existing cellular network with the Itron Transaction Management System (TMS) or other head-end systems and complies with ANSI. protocols for data storage and transmission. The I-210+c SmartMeter is a single-phase shed overall load at the premise without each interval are also transmitted to TMS, electronic watt-hour meter for use in regards to specific appliance. This 200- which interprets them and logs appropriate residential and light commercial service Amp switch may be used to throttle load messages ( time adjustments). locations. The I-210+c 's key features at the premise to a specific maximum Real-Time Interval Reads include Time of Use, Demand and Load threshold or to perform remote disconnects Profile, Remote Connect/Disconnect, and and reconnects. Real-time interval data acquisition enables compatibility.
2 The I-210+c meter utilities to implement Load Curtailment and Flexible Two-Way Data Retrieval and Real Time Pricing (RTP) programs. With may include an optional ZigBee wireless Scheduled Data Collection this functionality, the user can configure component for in-premise communications . and an optional Badger ORION wireless Users can execute all appropriate TMS the SmartMeter module to transmit load component for gas and water reads. functionality using user-configurable, profile data as often as every 15 minutes at SmartMeter -controlled schedules and interval completion. TMS-controlled schedules and as well as FUNCTIONS & FEATURES Automated Register, Self-Read and on an on-demand basis. TOU Retrieval Remote Disconnect/Reconnect Automated Interval Data/Energy The I-210+c SmartMeter module is Usage Retrieval configured by TMS to read and transmit all Remote connect and disconnect functionality is supported by the I-210+c The I-210+c SmartMeter module retrieves or a subset of enabled registers, including single-phase SmartMeter , which has a and transmits interval data for 1 energy totals, self-reads, maximum demand and load-limiting switch that can be used to value for intervals as small as 5 minutes.
3 Time-of-use values. Recorded events and exceptions with SPECIFICATIONS. Demand Resets is repeated a minimum number of times the SmartMeter module, utilizing a unique The I-210+c SmartMeter module within a specific duration. TMS can also meter-specific encryption key. executes Demand Resets using one of configure the SmartMeter to reset the Bi-Directional Metering three methods: SmartModule-initiated event counter when the alert message is transmitted. The I-210+c SmartMeter is a bi-directional schedules, TMS-initiated schedules or meter that supports Net Metering. Both TMS on-demand requests. Tilt Detection received and delivered data metrics are Real-Time Meter Event and Alarm The I-210+c SmartMeter can detect stored in the meter and can be delivered Retrieval and report tilt events that occur when to the utility as needed to support green- The I-210+c SmartMeter provides the SmartMeter is moved from its credit electricity programs for consumers automatic real-time alarm reporting of installation position.
4 Who own renewable energy facilities or all events defined in the ANSI participate in vehicle-to-grid systems. Meter Clock Synchronization standard, including history and event If enabled, the SmartModule automatically Over-The-Air SmartMeter Module codes, ANSI Standard status and Firmware Upgrade manufacturer status alarms. Additionally, adjusts the meter clock when the time deviation falls within user-defined lower TMS users with administrator privileges can alarms received by TMS can be and upper deviation boundaries based on remotely upgrade the I-210+c SmartMeter automatically routed via e-mail to a specific a reference clock provided by TMS. If the module firmware for one or multiple user or group of users using the TMS. deviation exceeds the upper boundary, the communication modules. Message Routing Interface. module reports the deviation via an alarm Transmission Efficiency Real-Time Power Outage and but does not correct the meter clock. If the Restoration Alarms deviation is less than the lower boundary, In addition to support for allowing users With built-in ultracapacitor energy the module ignores the deviation.
5 To filter the number of meter channels storage, the I-210+c SmartMeter module and types of diagnostics that are returned, SmartMeter Status Display all wireless messages are converted will transmit a real-time last gasp . notification when detecting an AC power The I-210+c SmartMeter supports to binary and optimally compressed outage without requiring the use of an optional LCD status sequence to before transmission to ensure the most less reliable batteries. The I-210+c display important SmartMeter indicators economical data processing rates. The SmartMeter also notifies TMS when the periodically. This status sequence compression ratio can be as high as AC power is restored and provides full includes the meter site coverage status, 50% and overall data usage can be as configuration of these alarms based on SmartModule firmware state and any little as 5% of the total usage of other user-defined durations. SmartModule firmware warnings/errors wireless systems. enabling technicians to ensure proper Service Diagnostic and Tamper Automated ID Tracking installation of the I-210+c SmartMeters Detection Alerts and allow field troubleshooting without any Barcode labels and important identifiers The I-210+c SmartMeter can report power other tools.
6 ( ICC-ID / MS-ISDN) are attached to service and wiring errors detected by the the integrated SmartMeter for tracking and meter, including reverse polarity, cross- Automated Meter Registration troubleshooting purposes. The SmartMeter phase and energy flow, phase voltage The SmartMeter module automatically module manufacturer and meter integrator deviation, inactive phase current, phase transmits a registration message to scan and track all device IDs accurately. angle displacement and current waveform TMS when the meter is installed without On-Demand Data Reads For distortion. In addition, the SmartMeter requiring user intervention. This message Virtual Disconnect can detect and report exceptions for permits TMS to create or update the meter record with validated information, ensuring Customers can perform virtual disconnects the following tamper events: number of accurate and automated record entries through TMS by retrieving a final read Demand Resets, Loss of AC power and without user intervention.
7 For one end-user and an initial read for reported power outages. a subsequent end-user. This function TMS configures a specific filter in Secure and Encrypted Data may also be used to perform meter the SmartMeter for each of these Transmissions switch-outs.. events, enabling the transmission of a 256-bit encryption is applied to all corresponding alert only after the event messages exchanged between TMS and SPECIFICATIONS HARDWARE. Radio Control Module Board (RCM) 32-bit ARM processor, 8MB RAM, 4MB flash Temperature Ranges Supplies peak power for data transmissions and all Capacitor Storage Bank (CSB). functions during power outages no batteries required Operating: [-40 C, +85 C]. Modem communicates with head-end using HSDPA or Modem Transmission (wireless): [-40 C, +85 C] EVDO and SMS services Wireless component configurable for two-way GHz Transceiver communications/WPAN Humidity Range Internal Antenna Flexible dual frequency antenna for the modem 0% to 95% non-condensing INPUT/OUTPUT SIGNAL.
8 Accuracy Module Power Input Voltage 120 - 240 VAC. Meets ANSI for accuracy Meter Serial Interface / TTL compatible asynchronous class VERSION AND COMPATIBILITY. Supported Meter Forms Supported meter forms, classes, and types, Without Disconnect I-210+c Meter Hardware: equipped with battery Class 20: 3S, 4S I-210+c Meter Firmware: Latest fully supported Class 100: 1S SmartModule: I-210+c GPRS SmartMeter Module Class 200: 2S, 12S, 25S Itron TMS: Version or higher for HSDPA, for EVDO. Class 320: 2S. Integration Supported Meter Forms The SmartMeter module is a fully integrated, under-the-cover option inside the With Disconnect I-210+c meter. The I-210+c SmartMeter is shipped as one complete unit, ready for Class 100: 1S field deployment. Class 200: 2S, 12S, 25S. Regulatory & Industry Certifications FCC Part 15 Class B. ANSI 1989: Surge Withstand Capability (SWC). ANSI (Class ) 1998. PTCRB Certified Measurement Canada Certified Network Carrier Certified Itron is a global technology company.
9 We build solutions that help utilities CORPORATE HEADQUARTERS. measure, monitor and manage energy and water. Our broad product portfolio 2111 N Molter Road includes electricity, gas, water and thermal energy measurement and control Liberty Lake, WA 99019. technology; communications systems; software; and professional services. USA. With thousands of employees supporting nearly 8,000 utilities in more than 100 countries, Itron empowers utilities to responsibly and efficiently manage Phone: energy and water resources. Fax: Join us in creating a more resourceful world; start here: While Itron strives to make the content of its marketing materials as timely and accurate as possible, Itron makes no claims, promises, or guarantees about the accuracy, completeness, or adequacy of, and expressly disclaims liability for errors and omissions in, such materials. No warranty of any kind, implied, expressed, or statutory, including but not limited to the warranties of non-infringement of third party rights, title, merchantability, and fitness for a particular purpose, is given with respect to the content of these marketing materials.
10 Copyright 2012, Itron. All rights reserved.