Example: dental hygienist

IEC 61850 通訊協定GOOSE功能性研究探討

37 IEC 61850 GOOSE 33 IEC 61850 GOOSE IED IEC 61850 (Communication Networks and Systems in Substations) GOOSE (Generic Object Oriented Substation Event) SCHNEIDER SepamT87 VA M P V52 AREVA P143 IEC 61850 GOOSE I.

iec 61850 通訊協定goose功能性研究探討 電驛協會會刊37期 34 圖1 iec 61850 變電站之分層架構 iec 61850對網路上可訪問的資訊進行

Tags:

  61508

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of IEC 61850 通訊協定GOOSE功能性研究探討

1 37 IEC 61850 GOOSE 33 IEC 61850 GOOSE IED IEC 61850 (Communication Networks and Systems in Substations) GOOSE (Generic Object Oriented Substation Event) SCHNEIDER SepamT87 VA M P V52 AREVA P143 IEC 61850 GOOSE I.

2 IEC 61850 (Communication networks and systems in substations) [1] IEC 61850 IEC 61850 IED IED IEC 61850 GOOSE IED IEC 61850 GOOSE II. (1) IEC 61850 IEC 61850 3 [2] (Station Level) (Bay Level) (Process Level) 1 IEC 61850 GOOSE 37 34 1 IEC 61850 IEC 61850 IEC 61850 ACSI ACSI SCSM [3] ASCI (request) (response) (event) ACSI (1) / (Client/Server-C/S) (2) (peer-to-peer)

3 GOOSE IEC 61850 SCSM ACSI MMS SCSM (MMS) (International Organization for Standardization) MMS (IED) (RTU-Remote Terminal Unit) MMS IEC 61850 MMS MMS MMS IEC 61850 MMS MMS (abstract syntax notation one) MMS (Abstract Communication Service Interface-ACSI) (Manufacturing Message Specification-MMS) TCP/IP IEC 61850 (XML - Extensible Mark Language) (SCL) IEC 61850 IEC 61850 (SCL)

4 IEC 61850 -6 37 IEC 61850 GOOSE 35 IEC 61850 IEC 61850 IEC 61850 KEMA UCA IEC 61850 [4] 3 (Station Level) (Bay Level) (Process Level): 1. Station Level 2. Bay Level 3. (Process Level) IED [1] [2] [3] (2) IED IEC 61850 PLC RTU IEC 61850 IEC 61850 (registers) 100 Mbps IEC 61850 (Logical Node LN) (Physical Device PD)

5 LN LN (Logical Connection LC) LN (Physical Connection PC) (Data Object DO) 1 (Data Attribute DA) (Logical Device LD) (Server) 1 1 IEC 61850 2 IEDs IEC 61850 GOOSE 37 36 2 IEC 61850 IEC 61850 IED IEC 61850 (Logic Node) PTOC(Phase Time Over Current) A A51_PTOC B OC_PTOC (XCBR) 3 3 IEC 61850 Relay IED IEC 61850 (mapping) IEC 61850 (3)GOOSE GOOSE Peer-to-Peer [5-6] GOOSE 100 Mbs GOOSE : 61850 3.

6 IED IED IED (buffer/unbuffer) IED GOOSE 61850 GOOSE GOOSE (4) GOOSE IED GOOSE IED IEC 61850 37 IEC 61850 GOOSE 37 IEC 61850 GOOSE IEC 61850 IEC 61850 SCHNEIDER SepamT87 x2 VA M P V52 Micom (AREVA) P143 [7-9] MOXA IEC 61850 Switch GPS IEC 61850 GOOSE (SCADA) 4 IEC 61850 GOOSE 4 GOOSE GOOSE GOOSE DATASET GOOSE DATASET DATASET GOOSE DATASET GOOSE Id GOOSE Id GOOSE Id GOOSE Id DATASET GOOSE Id GOOSE Id 5 GOOSE (STAR)

7 5 GOOSE IED IEC 61850 GOOSE IED IEC 61850 DATASET IEC 61850 GOOSE 37 38 GOOSE GOOSE GOOSE IEC61580 IEC 61850 GOOSE SCL GOOSE GOOSE GOOSE GOOSE 6 7 8 9 10 6 P143 (B Relay) GOOSE Sepam T87 (A Relay) 5ms GOOSE 6 A Relay B Relay GOOSE 7 P143 (B Relay) GOOSE VAMP52 (C Relay) 12ms 7 C Relay B Relay GOOSE 8 Sepam T87 (A Relay) GOOSE VAMP52 (C Relay) 18ms 8 C Relay A Relay GOOSE 9 Sepam T87 (A Relay) GOOSE P143 (B Relay) 18ms 37 IEC 61850 GOOSE 39 9 B Relay A Relay GOOSE 10 VAMP52 (C Relay) GOOSE P143 (B Relay)

8 11ms 10 B Relay C Relay GOOSE GOOSE 11 GOOSE GOOSE 11 GOOSE IEC 61850 IEC 61850 CID 12 13 100/5 2A SISCO (Simulator for Integrated Supply Chain Operations) [10] 12 40A SISCO 13 SISCO IEC 61850 IEC 61850 IEC 61850 GOOSE 37 40 12 13 IEC 61850 CID 14 14 XCBR LN XCBR LN/DO (Data Object) LN LN III.

9 IEC 61850 TCP/IP IEC 61850 IEC 61850 DI/DO IEC 61850 GOOSE 37 IEC 61850 GOOSE 41 [1] [2] S. J. Zhang, M. Sun, and G. F. Ge, The Research Based on IEC 61850 Intelligent Terminal of Substation, in Proc. of the 2011 IEEE 3rd International Conference on Communication Software and Networks, pp. 304-307, 2011. [3] H. Wang, Z.

10 Cai, Z. Su, and Z. Zhu, Analysis of realtime performances of process-level networks based on IEC 61850 SCSM Model, in Proc. of the 2011 4th International Conference on


Related search queries