Example: dental hygienist

IEC Contactor Specifications - ideadigitalcontent.com

Technical DataIEC Contactor SpecificationsBulletin Numbers 100/104-K, 100/104-C, 100/ 104s -C, 100/104-D, 100s -D, 100-G, 100Q-C To picPageProduct Line Overview3100-K/104-K Miniature Contactors5 Coil Voltage Codes5 Assignment of Contacts6 Specifications8 Life-Load Curves12 Approximate Dimensions14100-C/104-C, 100s -C/ 104s -C, 100Q-C Contactors15 Coil Voltage Codes15 Assignment of Contacts18 Specifications25 Life-Load Curves36 Maximum Operating Rates42 Approximate Dimensions46100-D/104-D, 100s -D Contactors51 Coil Voltage Codes51 Specifications53 Life-Load Curves63 Approximate Dimensions65100-G Contactors67 Coil Voltage Codes67 Specifications67 Life-Load Curves73 Permissible Switching Rate75 Approximate Dimensions772 Rockwell Automation Publication 100-TD013E-EN-P - June 2015 IEC Contactor Specificatio

4 Rockwell Automation Publicatio n 100-TD013E-EN-P - June 2015 Safety Contactors Bulletin No. 100S-C/104S-C 100S-D Screw Terminals Thru-hole, threaded (630…860 A) Max.Current Ie 97 A 860 A

Tags:

  Specification, Safety, Bulletin, Contactors, 100s, Iec contactor specifications, Safety contactors bulletin, 104s, C 100s

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Advertisement

Transcription of IEC Contactor Specifications - ideadigitalcontent.com

1 Technical DataIEC Contactor SpecificationsBulletin Numbers 100/104-K, 100/104-C, 100/ 104s -C, 100/104-D, 100s -D, 100-G, 100Q-C To picPageProduct Line Overview3100-K/104-K Miniature Contactors5 Coil Voltage Codes5 Assignment of Contacts6 Specifications8 Life-Load Curves12 Approximate Dimensions14100-C/104-C, 100s -C/ 104s -C, 100Q-C Contactors15 Coil Voltage Codes15 Assignment of Contacts18 Specifications25 Life-Load Curves36 Maximum Operating Rates42 Approximate Dimensions46100-D/104-D, 100s -D Contactors51 Coil Voltage Codes51 Specifications53 Life-Load Curves63 Approximate Dimensions65100-G Contactors67 Coil Voltage Codes67 Specifications67 Life-Load Curves73 Permissible Switching Rate75 Approximate Dimensions772 Rockwell Automation Publication 100-TD013E-EN-P - June 2015 IEC Contactor SpecificationsAdditional ResourcesThese documents contain additional information concerning related products from Rockwell can view or download publications at To order paper copies of technical documentation.

2 Contact your local Allen-Bradley distributor or Rockwell Automation sales Automation Wiring and Grounding Guidelines, publication general guidelines for installing a Rockwell Automation industrial Certifications website, declarations of conformity, certificates, and other certification Automation Publication 100-TD013E-EN-P - June 20153 Product Line OverviewIEC ContactorsBulletin Terminals Thru-hole, threaded ( A)Thru-holeSpring Terminals ( A) ( A) Ie12 A97 A37 A860 A1200 ACurrent A16, 32 AFeatures Mini- contactors Uniform panel mounting dimensions Panel mounting or mounting on 35 mm DIN Rail AC or DC coil control Made of environmentally friendly materials Panel mounting or mounting on 35 mm DIN Rail AC or DC coil control Reversible coil terminals (line or load side) Common accessories Made of environmentally friendly materials Panel mounting or mounting on 35 mm DIN Rail AC or DC coil control Reversible coil terminals (line or load side)

3 Common accessories Made of environmentally friendly materials Panel mounting only Made of environmentally friendly materials AC or DC coil control (conventional or electronic) Integrated PLC interface (electronic coil) Panel mounting AC or DC coil control Horizontal or vertical interlock Latching 4th poleContacts3 power poles with internal or auxiliary contact, or 4 power front-mounted 2- or 4-pole external auxiliary contact power poles with internal or auxiliary contact or 4 power poles. Optional front- or side-mounted 1-, 2- or 4-pole external auxiliary contact main poles with front-mount resistor elements.

4 Optional side-mounted 1-, 2- or 4-pole external auxiliary contact power poles with external and side-mounted auxiliary contact. Optional side-mounted 2-pole external auxiliary contact blocks3 power poles with and front-mounted auxiliary contact. Optional 4th pole and auxiliary contactsCoil VoltagesAC = , 50/60 HzDC = = , 50/60 HzDC = = , 50/60 HzDC = CoilsCat. Nos. : 50 Hz, 60Hz, 50/60 HzDC: DCElectronic CoilsCat. Nos. : 50/60 HzDC: DCCat. Nos. 100-D420AC: 50/60 HzDC: DCCat. Nos. : 50/60 HzDC.

5 DCAC = , 50/60 HzDC = Overload RelaysElectronic or bimetallicElectronic or bimetallic ElectronicElectronicOptional Accessories Front-mount auxiliary contacts Surge suppressors Electronic timers Mechanical interlocks Front or side-mount auxiliary contacts Surge suppressors Electronic or pneumatic timers Mechanical interlocks Mechanical latches Side-mount auxiliary contacts Surge suppressors Electronic timers Side-mount auxiliary contacts Surge suppressors IP20 terminal blocks Te r m i n a l s h i e l d s Terminal covers Connecting

6 Components Te r m i n a l l u g s Mechanical/electrical interlocks Auxiliary contact 4th pole Vertical interlock Horizontal interlock Mechanical latchStandards/Certifications UL CSA IEC CE Marked CCC UL CSA IEC CE Marked CCC UL CSA IEC CE Marked UL CSA IEC CE Marked CCC( A - conventional coil; A - electronic coil) UL CSA IEC CE Marked4 Rockwell Automation Publication 100-TD013E-EN-P - June 2015 safety ContactorsBulletin Terminals Thru-hole, threaded ( A) Ie97 A860 ACurrent AFeatures Positively guided/mechanically linked auxiliary contacts Front-mounted auxiliary contacts.

7 Permanently fixed Protective cover to prevent manual operation Red contact housing for easy identification Incorporates IEC 947-5-1 Mechanically Linked symbol Optional gold-plated bifurcated versions AC and DC operating coils SUVA third-party certification Mirror contact performance on auxiliary contacts, which are required in feedback circuit for modern safety applications. The auxiliary contacts will not change state when a power contact welds. SUVA third-party certification AC and DC operating coils "Mirror Contact" symbolContacts3 main poles with mechanically linked feedback contacts3 main poles with mechanically linked feedback contactsCoil VoltagesAC = , 50/60 HzDC = CoilsCat.

8 Nos. : , 50 Hz; , 60Hz; , 50/60 HzDC: CoilsCat. Nos. : , 50/60 HzDC: Nos. 100s -D420AC: 50/60 HzDC: Nos. : , 50/60 HzDC: Accessories Side-mount auxiliary contacts Surge suppressors Electronic timers Mechanical interlocks Side-mount auxiliary contacts Surge suppressors IP20 terminal blocks Terminal shields Terminal covers Connecting components Te r m i n a l l u g s Mechanical/electrical interlocksStandards Compliance EN/IEC 60947-4 IEC 60947-5-1 Annex L Mechanically Linked Contacts IEC 60947-4-1 Annex H Mirror Contacts UL 508 CSA No.

9 14 EN50205 EN/IEC 60947-4 IEC 60947-4-1, Annex H Mirror Contacts IEC 60947-4-1/A1: 2002-09, Annex F UL 508 CSA , No. 14 Certifications cULus Listed (File No. E3125; Guide NLDX, NLDX7) SUVA Third-Party Certified CE Marked cULus Listed (File No. E3125; Guide No. NLDX, NLDX7) SUVA Third-Party Certified CE Marked CCC ( A - conventional coil; A - electronic coil)Rockwell Automation Publication 100-TD013E-EN-P - June 20155100-K/104-K Miniature ContactorsCoil Voltage Codes Coil Voltage Code for screw type terminal versionsThe Cat. No.

10 As listed is incomplete. Select a coil voltage code from the table below to complete the Cat. No. Example: 120V, 60 Hz: Cat. No. 100-K09 10 becomes Cat. Coil Voltage Code for spring clamp type terminal versionsThe Cat. No. as listed is incomplete. Select a coil voltage code from the table below to complete the Cat. No. Example: 120V, 60 Hz: Cat. No. 100-KR09 10 becomes Cat. Voltages [V]2411012023024040048060050 Hz D 60 Hz D B VC50/60 Hz KJ KFKAKN DC Voltages [V]1224110125220250 StandardZQZJZDZSZAZT with Integrated Diode DJ AC Voltages [V]2411012023050 Hz D 60 Hz D 50/60 Hz KJ KFDC Voltages [V]24110 StandardZJZD with Integrated Diode DJ 6 Rockwell Automation Publication 100-TD013E-EN-P - June 2015 Assignment of ContactsDevice Combinations in Accordance with IEC 60947-1 / -4-1 Table valid for : AC / DC = x Us, Tamb.