1 Installation & Instruction ManualInstallation & Instruction ManualElectrical Control (BOARD 070E)Electrical Control (BOARD 070E)READ AND FOLLOW ALL instructions . SAVE THESE instructions . GIVE TO # Model # Wiring Diagram # Project #/Name Door #/Name For technical support, please call 1-800-361-2260 or visit for more informationMicroprocessor (Chip)2 TABLE OF CONTENTSI nstallation Electrical Power Supply Board Jumper Settings - JP2 Accessory Electrical Wiring with BOARD Electronic Control Board (ECB) BOARD LED Monitoring Control Board (ECB) On-Board Radio Receiver Components and Compatible Transmitting Control Functions 1 and 3-Button.
2 Technical support, please call 1-800-361-2260 or visit for more information3 Installation Instructions1 Electrical Wiring WARNINGTo reduce risk of SEVERE INJURY or DEATH to persons: All electrical wiring should be done by a qualified professional and in accordance to localelectrical codes. Always shut OFF the main power before performing any electrical intervention. Use proper wire gauge for incoming power line and for accessory connections. Install operator main circuit breaker next to operator for easy access for power shut-off. Use separate knockouts on operator control box for accessories and main power cables. Always separate low and high voltage wires. Operator should be properly grounded to the building ground and to the main power supply ground lug. Always use suitable and appropriate rating circuit breakers for operator protection.
3 Compare available power supply voltage to voltage on operator name plate prior to electrical connection. Failure to connect appropriate power supply voltage may cause serious damage to the technical support, please call 1-800-361-2260 or visit for more information4 NOTICE The installer MUST test for proper connection and functionality of the operator and its accessories before leaving the job site. The installer should also perform a demonstration for the Power Supply ConnectionSingle-Phase (115/230V)Three-Phase (208/230-460-575V)Correct motor rotation: Switch the BLUE and ORANGE motor wires on the power motor rotation: Switch ANY TWO incoming lines(phase) on the power terminal Board Jumper Settings - JP2 Set-UpFor medium-duty operators (OMH, OMJ and OMT ), JP2 must be set on 2 and other models, JP2 must be set on 1 and 2 for single phase operators, or set on 2 and 3 for 3 phase technical support, please call 1-800-361-2260 or visit for more informationLine 3 Line 2 Line 1 Ground LugPower Terminal BlockNEUTRALLIVEG round LugPower Terminal BlockFigure 1 - Electronic Control Board BOARD Connection WARNING Wall controls must be mounted in clear view of the door, far enough from the door, or positioned such that the user is prevented from coming in contact with the door while operating the controls and at least 5 feet (1,5 m) above the standing surface.
4 Keep low voltage wires separate from line voltage wires. Use copper conductors Station (PBS) ConnectionFigure 2 - STATION 020 / 0843-PBS Open / Close / StopFigure 3 - STATION 041 / 049 / 056 / 076 / 0783-PBS Open / Close / StopFigure 4 - STATION 0793-PBS Open / Close / Stop with Key Lock-outFigure 5 - STATION 0803-PBS Open / Close / Stop with Key Lock-out and LightFigure 6 - STATION 001 / 0811-PBS OpenFigure 7 - STATION 010 / 0822-PBS Open / CloseFor technical support, please call 1-800-361-2260 or visit for more Accessory ConnectionsNOTICE Photo cells must be installed facing each other across the door's path within 6 (15 cm) of the plane ofthe door and the beam no more than 5-3/4 (14,6 cm) above the floor. Keep low voltage wires separate from line voltage wires. Use copper conductors Photo Cells / Photo Eyes (Non-Monitored)Through Beam TypeFigure 8 - PHOTO 008A/BFigure 9 - PHOTO 015 / 016 / 045 / 050 / 051 / 059 Reflective TypeFigure 10 - PHOTO 018 Figure 12 - PHOTO 038 For technical support, please call 1-800-361-2260 or visit for more informationFigure 11 - PHOTO Edge Device (Non-Monitored)NOTICE If the door is controlled by any device other than a constant pressure push-button station on close, including a timer-to-close, a reversing edge must be Sensing Edge1.
5 Place the air switch in position, refer to Figure Place the air hose in Use a coil cord or take-up reel to connect the airswitch to the operator terminals. Install electricwires according to Figure 14 or Figure Connect one end of the air hose to the Place the air plug in the other end of the Sensing Edge1. Place the junction box in position, refer to Figure Place the sensing edge in Use a coil cord or take-up reel to connect thesensing edge wires to the operator electric wires according to Figure Connect the sensing edge to the junction N/AFigure 14 - AIRSWITCH 001 / 007 Figure 15 - AIRSWITCH 009 Figure 16 - Electric Reversing EdgeFor technical support, please call 1-800-361-2260 or visit for more informationFigure 13 - Reversing Cord & Key SwitchFigure 17 - PULLCORD 001 / 003 / 004 / 007 Figure 18 - KEYSWITCH 010 / 015 Figure 19 - KEYSWITCH Loop DetectorFigure 20 - Vehicle Loop AccessoriesAdditional accessories are available, such as.
6 Universal Auxiliary Output Module External Mid-Stop Switch External Timer Defeat SwitchPlease contact your dealer or our inside sales department at 1-800-361-2260 for further technical support, please call 1-800-361-2260 or visit for more information2-Position Key Switch2-Position Key Switch & Stop ButtonRecommendation: Put Control Board on C2 or E2 Mode (constant-pressure-to-close)Twist the two (2) leads (wires) a minimum of 6 twists/foot92 Electrical Wiring with BOARD 070 EFor JP2 on-board jumper settings for medium-duty models (OMH, OMJ and OMT), refer to section , p. 4 technical support, please call 1-800-361-2260 or visit for more informationFigure 21 - External Wiring10 User InstructionsIMPORTANT SAFETY instructions WARNINGTO REDUCE THE RISK OF SEVERE INJURY ORDEATH TO PERSONS:1. READ AND FOLLOW ALL Never let children operate or play with door controls.
7 Keep the remote control (whereprovided) away from Personnel should keep away from a door in motion and keep the moving door in sightuntil it is completely closed or opened. NO ONE SHOULD CROSS THE PATH OF AMOVING Test the door's safety features at least once a month. After adjusting either the force orthe limit of travel, retest the door operator's safety features. Failure to adjust theoperator properly may cause severe injury or For products having a Manual release, if possible, use the Manual release only whenthe door is closed. Use caution when using this release with the door open. Weak orbroken springs may cause the door to fall rapidly, causing severe injury or death. 6. KEEP DOORS PROPERLY OPERATING AND BALANCED. See Door Manufacturer sOwner Manual . An improperly operating or balanced door could cause severe injury ordeath.
8 Have trained door systems technician make repairs to cables, springassemblies and other SAVE THESE more information or for immediate assistance, please contact your local technical support, please call 1-800-361-2260 or visit for more information111 Electronic Control Board (ECB) BOARD LayoutFor technical support, please call 1-800-361-2260 or visit for more informationFigure 22 - Electronic Control Board BOARD 070 EJP4 for HoistPower SocketJP2 Output ModuleSocketControl SocketRadio ReceiverIndicator LEDD2 (Green) / D3 (Red)LED D1 (Green)LED D5 (Red) / D6 (Red)LEDD12 (Red) / D13 (Red) / D14 (Red)Rotary Selection SwitchLED D10 (Red) / D11 (Red)On-Board Push-Buttons2 Amp FuseMicroprocessor (Chip)External AccessoriesTerminal StripLEDD7 (Red) / D8 (Red) / D9 (Yellow) LED Monitoring StatusThe electronic control board's LEDs help with wiring and troubleshooting diagnostics.
9 Every LED indicates the statusof the door. BOARD 070E has a non-volatile memory and the LEDs return to their initial state after a powerinterruption. Refer to Figure 22, p. 11 as 1 - LED Monitoring StatusLEDLED ONFunctionsD1 GREENI ndicates presence of / D3 Refer to Table 2, as when single-button radio transmitter is activated (stays ON for +/- 1 sec).D6 REDWhen reversing or sensing edge is close command is open command is that the stop button is connected and hoist or disconnectswitch is not inductive loop (Terminal #12) is activated (when loop is activated, door could be closed only on constant pressure).D11 REDWhen external timer to close defeat switch is activated (if used).D12 REDWhen open limit switch is external mid-stop limit switch is activated (if used).D14 REDWhen close limit switch is technical support, please call 1-800-361-2260 or visit for more / D3 LED Monitoring Status Combination ScenariosTable 2 - D2/D3 LED Monitoring Status - Combination ScenariosScenarioD2 LEDGREEND3 LEDREDF unctions1 OFFOFFI ndicates a DC power door is operator is on wrong handling feature activation (if a limit switch is not released/deactivated within sec while door starts to close/open from the fully open/closed positions).
10 5 ONONI ndicates a faulty motor centrifugal switch (single-phase only).6 FlashOFFWhen door is timer to close is counting before closing the door is opening during programming of the run timer or the mid-stop features. Refer to section , as technical support, please call 1-800-361-2260 or visit for more Control Board (ECB) Programming WARNINGTo reduce risk of SEVERE INJURY or DEATH to persons: Manaras-Opera strongly recommends the use of external entrapment protection devices, especially inthe case of momentary contact to close (B2 wiring or Timer to Close). Mode SettingsNOTICE Always return the door to fully closed position before performing any program ModeSelector switchposition on 0 SET SELECT SWITCH ON C2 = 0 Function: Momentary contact to open and stop, constant-pressure-to-close with 3-button station. Activation of entrapment protection devices will reverse the door while closing.