Installation and User's Manual for Modular Cuber Models C0322, C0522, C0722, C0330, C0530, C0630, C0830 and C1030. C0322 through C1030. Air and Water Cooled User Manual Introduction The design of this Modular Cuber is the result of years This Installation and user Manual is divided into of experience and testing. Standard features include three main sections: Installation , which provides front accessible indicator lights and on-off switches the trade person with the information needed to that provide the user with fast access to critical set up and install this product; Use and Operation, information and easy operational control. which provides the user with the information to use the product; and Maintenance, which provides the Keep this Manual for future reference. user with the information needed keep it operating efficiently.

Installation and User’s Manual for Modular Cuber Models C0322, C0522, C0722, C0330, C0530, C0630, C0830 and C1030

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Advertisement

Transcription of Installation and User’s Manual for Modular Cuber Models ...

1 Installation and User's Manual for Modular Cuber Models C0322, C0522, C0722, C0330, C0530, C0630, C0830 and C1030. C0322 through C1030. Air and Water Cooled User Manual Introduction The design of this Modular Cuber is the result of years This Installation and user Manual is divided into of experience and testing. Standard features include three main sections: Installation , which provides front accessible indicator lights and on-off switches the trade person with the information needed to that provide the user with fast access to critical set up and install this product; Use and Operation, information and easy operational control. which provides the user with the information to use the product; and Maintenance, which provides the Keep this Manual for future reference. user with the information needed keep it operating efficiently.

2 Contents Introduction.. Page 1. Installation : Product Specifications .. Page 2. Model Number Description .. Page 3. Product Description & Electrical Requirements.. Page 4. C0322 and C0522 Cabinet Layout .. Page 5. C0330, C0530, C0630 and C1030 Cabinet Layout .. Page 6. C0722 Cabinet Layout.. Page 7. Water .. Page 8. Panel Removal .. Page 9. Plumbing Requirements.. Page 10. Electrical.. Page 11. Final Check List .. Page 12. Initial Start Up .. Page 13. Adjustments.. Page 14. Use and Operation .. Page 15. Control Switches.. Page 16. Options .. Page 17. Cleaning, Sanitation and Maintenance .. Page 18. Air cooled condenser filter.. Page 20. What to do before calling for service .. Page 21. Note any Caution or Warning symbols when they appear on the product or in this Manual . They indicate potential hazards.

3 November 2012. Page 1. C0322 through C1030. Air and Water Cooled User Manual Installation : Product Specifications Location Limitations: Environmental Limitations The product is designed to be installed indoors, in a Minimum Maximum controlled environment. Air cooled Models discharge Air temperature 50oF. 100oF. very warm air into the room out the back. Space must Water temperature 40oF. 100oF. be allowed at the left side and back for air intake and discharge. Water cooled Models discharge warm Water pressure 20 psi 80 psi water into the building's drain. Power supply acceptable voltage ranges Space needs to be provided on both sides and above for service access. Minimum Maximum 115 volt model 104 volts 126 volts Space Limitations 230 volt model 198 volts 253 volts Note: Although the machine will function, ice capacity of air cooled machines will be significantly reduced Warranty Information with minimal clearance at the sides, back and top.

4 Some space is recommended for service and The warranty statement for this product is provided maintenance purposes on all Models . 6" of space separately from this Manual . Refer to it for applicable at the sides and back are required for adequate coverage. In general warranty covers defects operation. To get the most capacity, locate the in material or workmanship. It does not cover machine away from heat producing appliances and maintenance, corrections to installations, or situations heating ducts, and keep the left side away from any when the machine is operated in circumstances that wall, allow 12-18 inches of space at the left for exceed the limitations printed above. good air flow. Product Information Airflow is in the left side, out the back (as viewed from the front). The product is a Modular Cuber .

5 That type of machine is designed to be placed on an ice storage bin or an ice dispenser. Many installations only require the matching bin, but some also require an adapter to be placed between the bin and the Cuber or between the dispenser and the Cuber . This product cannot be stacked. See the chart for application information. Air Flow November 2012. Page 2. C0322 through C1030. Air and Water Cooled User Manual Model Number Description Example: C0530, Does not Direct fit KBT28 KBT22. C0630, fit C0322SA-1B. C0830, C= Cuber C1030. 03= nominal ice capacity in 100s of pounds Hotel Dispensers 22= nominal width of cabinet The HD22 and HD30 are compatible with this ice S= Cube size. S=small or half dice cube. machine, no adapters are needed. Some typical M=medium or full dice cube combinations include: A=Condenser type.

6 A=air cooled. W=water cooled HD22 use with C0322 or C0522. -1=115 60 Hz, -32=208-230 60 Hz, -3= 208-230 3. phase 60 Hz HD30 use with C0330 or C0530. B=Series revision code. B=second series Note: All Models ship with the On and Off switches front accessible. If desired, the On and Off switches Note: Listed model numbers typically include only the can be covered but by changing the bezel in the front first five characters of the model number. panel's trim strip, available from a local distributor. Options: Ice and Beverage Dispensers Adapter There are several field-installed options that can be information installed at initial start up or later. They include: Model ID150 ID200 or ID250. KVS, Vari-Smart Adjustable ice level system. C0322, C0522, KBT42 KBT43. KSB, SmartBoard Advanced feature board. C0722.

7 KPMFA223-B, front air flow panel. Fits C0322 and C0530, C0630, Does not fit KBT44. C0522. B series. C0830, C1030. KPMFA303-B, front air flow panel. Fits C0330, Other Bins & Applications: C0530, C0630. B or C series. KPFMA309-B, front air flow panel. Fits C0830 and Note the drop zone and ultrasonic sensor locations in C1030. B series. the illustrations on the next pages. A39514-021 air baffle for corner locations. Fits Scotsman ice systems are designed and C0322, C0330, C0522, C0722, C0530, C0630. manufactured with the highest regard for safety and A39515-021, air baffle for corner locations. Fits performance. C0830 and C1030. Scotsman assumes no liability of responsibility of Some installations require bin or dispenser adapters. any kind for products manufactured by Scotsman Standard Bin Applications - Adapter information.

8 That have been altered in any way, including the use of any part and/or other components not specifically Model B222 B530P, BH800, BH900, approved by Scotsman. B322 B330P, BH801, B948S. Scotsman reserves the right to make design changes B530S, B842S. and/or improvements at any time. Specifications and HTB555. design are subject to change without notice. C0322, Direct fit KBT27 Not Not C0522, available available C0722. November 2012. Page 3. C0322 through C1030. Air and Water Cooled User Manual Product Description & Electrical Requirements Dimensions w" x d" x h" Model Series Electrical Condenser Minimum Maximum volts/Hz/ Circuit Fuse Size*. phase Ampacity ** x 24 x 23 C0322SA-1 A or B 115/60/1 Air 15. C0322SW-1 A or B 115/60/1 Water 15. C0322SA-32 A or B 208-230/60/1 Air 15. C0322SW-32 A or B 208-320/60/1 Water 15.

9 C0522SA-1 A or B 115/60/1 Air 15. C0522SW-1 A or B 115/60/1 Water 15. C0522SA-32 A or B 208-230/60/1 Air 15. C0522SW-32 A or B 208-230/60/1 Water 15. ** x 24 x 23 C0330SA-1 A or B or C 115/60/1 Air 15. C0330SW-1 A or B or C 115/60/1 Water 15. C0330MA-32 A or B or C 208-230/60/1 Air 15. C0330SW-32 A or B 208-230/60/1 Water 15. C0530SA-1 A or B 115/60/1 Air 15. C0530SW-1 A or B 115/60/1 Water 15. C0530SA-32 A or B 208-230/60/1 Air 15. C0530SW-32 A or B 208-230/60/1 Water 15. C0530SA-1 C 115/60/1 Air 20. C0530SW-1 C 115/60/1 Water 15. C0530SA-32 C 208-230/60/1 Air 15. C0530SW-32 C 208-230/60/1 Water 15. C0630SA-32 A or B 208-230/60/1 Air 20. C0630SW-32 A or B 208-230/60/1 Water 17 20. ** x 24 x 29 C0722SA-32 B 208-230/60/1 Air 10 15. ** x 24 x 29 C0830SA-32 A or B 208-230/60/1 Air 15. C0830SW-32 A or B 208-230/60/1 Water 9 15.

10 C0830SA-3 A or B 208-230/60/3 Air 15. C0830SW-3 A or B 208-230/60/3 Water 15. C1030SA-32 A or B 208-230/60/1 Air 16 20. C1030SW-32 A or B 208-230/60/1 Water 15. C1030SA-3 A or B 208-230/60/3 Air 11 15. C1030SW-3 A or B 208-230/60/1 Water 15. Table notes: Medium cube Models have the same electrical characteristics as Small. Series revision code omitted. * Or HACR type circuit breakers. ** Maximum width at top panel. Air cooled Models add .75" for left side louvers. November 2012. Page 4. C0322 through C1030. Air and Water Cooled User Manual C0322 and C0522 Cabinet Layout .88" DIA. ELECTRICAL. ACCESS. 37. 3/8" FPT. 61 WATER INLET 3/4" FPT. DRAIN. LOUVER AND. AIR COOLED LEFT SIDE VIEW REMOVABLE FILTER. BACK VIEW AC UNITS ONLY. C0322, C0522 Air Cooled Side View C0322, C0522 Air Cooled Back View 26. ULTRASONIC BIN LEVEL SENSOR.