INSTALLATIONINSTRUCTIONSforSLO-SYN MODELS ss2000md7 & ss2000md7 -128 translator /DRIVE2 TABLE OF CONTENTS PageTHINGS TO KNOW BEFORE USING 1: This 2: EXPRESS START 3: INSTALLATION Locations And 4: Mechanical Electrical Environmental Motor Current Indicator 5: TORQUE VERSUS Torque Vs. Speed 6: A: TROUBLESHOOTING ELECTRICALINTERFERENCE TO KNOW BEFORE USING THISEQUIPMENT Only qualified personnel should install or perform servicingprocedures on this equipment. Do not operate the unit without theenclosures in place as voltage present in this unit can causeserious or fatal injury. Before performing any work on the unit, allow at least five minutesfor the capacitors to discharge fully. Voltage is present on unprotected pins when unit is operational. The "PWR ON" LED must be off for approximately 30 secondsbefore making or breaking the motor connections. Motors powered by this drive may develop extremely high sure to disconnect power to this drive before doing anymechanical :This unit is designed for 24 to 75 Vdc input only (see , Electrical Specifications, Page 11).

installation instructions for slo-syn® models ss2000md7 & ss2000md7-128 translator/drive

Tags:

  Model, Installation, Instructions, Installation instructions for slo syn, Models ss2000md7 amp ss2000md7 128 translator, Ss2000md7, Translator

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of INSTALLATION INSTRUCTIONS for SLO-SYN …

1 INSTALLATIONINSTRUCTIONSforSLO-SYN MODELS ss2000md7 & ss2000md7 -128 translator /DRIVE2 TABLE OF CONTENTS PageTHINGS TO KNOW BEFORE USING 1: This 2: EXPRESS START 3: INSTALLATION Locations And 4: Mechanical Electrical Environmental Motor Current Indicator 5: TORQUE VERSUS Torque Vs. Speed 6: A: TROUBLESHOOTING ELECTRICALINTERFERENCE TO KNOW BEFORE USING THISEQUIPMENT Only qualified personnel should install or perform servicingprocedures on this equipment. Do not operate the unit without theenclosures in place as voltage present in this unit can causeserious or fatal injury. Before performing any work on the unit, allow at least five minutesfor the capacitors to discharge fully. Voltage is present on unprotected pins when unit is operational. The "PWR ON" LED must be off for approximately 30 secondsbefore making or breaking the motor connections. Motors powered by this drive may develop extremely high sure to disconnect power to this drive before doing anymechanical :This unit is designed for 24 to 75 Vdc input only (see , Electrical Specifications, Page 11).

2 WARRANTY RESTRICTIONSR econfiguration of the circuit in any fashion not shown in this manual willvoid the to follow the INSTALLATION guidelines as described in Section 3 willvoid the 1: USING THIS MANUALIt is important that you understand how this SLO-SYN ss2000md7 translator /Drive is installed and operated before you attempt to use strongly recommend that you read this manual completelybefore proceeding with the INSTALLATION of this manual is an INSTALLATION and operating guide to the SLO-SYNSS2000MD7 translator /Drive. Section 1 gives an overview of the Driveand its features. Section 2 describes the steps necessary to place thedrive into operation. General wiring guidelines as well as the physicalmounting of the unit and connections to the drive portion are covered inSection specifications, listed in Section 4, provide easily referencedinformation concerning electrical, mechanical and environmentalspecifications.

3 The procedure for setting the motor current level is alsocovered in this versus speed characteristics with all appropriate SLO-SYNS tepper Motors are given in Section 5. Section 6, Troubleshooting, givesprocedures to follow if the translator /Drive fails to operate A provides procedures for troubleshooting electrical inter-ference PRODUCT FEATURESThe SLO-SYN ss2000md7 (MD7-128) translator /Drive is a bipolar,speed adjustable, two-phase PWM drive which uses power MOSFET devices. The MD7 can be set to operate a stepper motor in 1/2, 1/10,1/25 or 1/100 microsteps. The MD7-128 can be set to operate astepper motor in Full, 1/16, 1/64, or 1/128 microsteps. The maximumrunning speed is 3,000 rpm. To reduce the chances of electrical noiseproblems, the control signals are optically isolated from the drivecircuit. UL recognized under Component Program, File #E146240 Switch selectable current levels of 1 through 7 amperes Full short circuit protection (phase-to-phase and phase-to-ground) Undervoltage and transient overvoltage protection Thermal protection Efficient thermal design Optically isolated inputs Reduce Current and Windings Off capabilities Switch selectable step resolution Compact size Sturdy all-aluminum case5 SECTION 2: EXPRESS START UP PROCE-DUREThe following INSTRUCTIONS define the minimum steps necessary tomake your Drive :Always disconnect the power to the unit and be certain that the"PWR ON" LED is OFF before connecting or disconnecting themotor leads.

4 FAILURE TO DO THIS WILL RESULT IN A SHOCKHAZARD AND MAY DAMAGE THE operate the unit with the Motor and the Drive enclosureGROUNDED. Be sure to twist together the wires for each motorphase as well as those for the dc input. Six twists per foot is agood to see that the motor used is compatible with the to Section for a list of compatible the correct current level for the motor being used per theinstructions in Section Heat sinking is required if a currentof 4 amperes or higher is the appropriate step resolution and set the switches asdescribed in Section the motor per the "Motor Connections" description in Sec-tion the power source to the DC input terminal strip. Be sureto follow the INSTRUCTIONS for connecting the filter capacitor asdescribed in Section , under Power :If the motor operates erratically, refer to Section 5, "Torque VersusSpeed Characteristics".Clockwise and counterclockwise directions are properly orientedwhen viewing the motor from the end opposite the mounting 3: INSTALLATION MOUNTINGThe SLO-SYN Drive is mounted by fastening its mounting brackets to aflat surface as shown in Figure If the Heat Sink Assembly, partnumber 221576-001, is mounted against a bulkhead, be sure to apply athin coating of thermal compound between the heat sink and themounting surface before fastening the unit in place.

5 Do not use too muchthermal compound. It is better to use too little than too , Mounting DiagramNOTE:Case temperature should not exceed +70 C (+158 F). Aheat sink, such as Superior Electric Heat Sink Assembly221576-001, must be used when the drive is operated at acurrent setting of 4 amperes or more. In this case the unitshould be mounted upright (with the cooling fins vertical), or proper cooling will not occur. Air flow should not beobstructed. Forced air cooling may be required to maintaintemperature within the stated selecting a mounting location, it is important to leave at least twoinches (51mm) of space around the top, bottom and sides of the unit toallow proper airflow for is also important to keep the drive away from obvious noise sources. Ifpossible, locate the drive in its own metal enclosure to shield it and itswiring from electrical noise sources. If this cannot be done, keep the driveat least three feet from any noise LOCATIONS AND PIN ASSIGN-MENTSF igure shows the connector locations for the SLO-SYN ss2000md7 , Connector Locations8 MOTOR CONNECTIONSAll motor connections are made via the 6-pin connector, part number218397-006.

6 Pin assignments for this connector are given below. Motorconnections are shown in Figure (Phase A)2M3 (Phase A)3M4 (Phase B)4M5 (Phase B)NOTE:Motor phase A is M1 and M3 and motor phase B is M4 and motor frame must be from the drive to the motor should be done with a shielded,twisted-pair cable. As a guideline, the wires for each motor phase shouldbe twisted about six times per Electric offers the following motor cable configurations. Thesecables have unterminated leads on both Number 10 ft (3 m)216022-03125 ft ( m)216022-03250 ft ( m)216022-03375 ft ( m)216022-034 Figure shows the possible motor wiring *These leads must be insulated and isolated from other leadsor letters identify terminals for connector motors, numbers identifythose for terminal box , Motor Wiring ConfigurationsDFBH5413 WHITE/BLACKBLACKWHITE/REDREDGREENMOTOR TERMINAL "M" NUMBERSMOTORCONNECTOR PINMOTORCONNECTOR PIN4-LEAD MOTORSDFBH5413 GREENWHITE/REDRED6-LEAD *E2G * MOTORS, SERIES CONNECTIONSGBLACKAWHITEORANGEEGREENCWHIT E/GREEN*6278*DRIVE PIN 1 DRIVE PIN 2 DRIVE PIN 1 DRIVE PIN 2 DRIVE PIN 1 DRIVE PIN 2 DRIVE PIN 4 DRIVE PIN 3 DRIVE PIN 4 DRIVE PIN 3 DRIVE PIN 4 DRIVE PIN 3 DFBH5413 WHITE/REDRED8-LEAD MOTORS, PARALLEL CONNECTIONSWHITE/BLACKGBLACKAWHITEORANGE EC6278 GREENWHITE/GREENDRIVE PIN 4 DRIVE PIN 3 DRIVE PIN 1 DRIVE PIN 2610 POWER INPUTThe dc input power is connected to pins 5 and 6 of the power 5 [Vm(+)] is the power supply plus (+) connection and pin 6 [Vom(-)]is the power supply minus (-)

7 Unregulated supply similar to that shown in Figure ispreferable. If a regulated supply is used, it must be a linearregulated supply and must be capable of operating with the addedfilter capacitor. A switching regulated supply is not recommendedfor use with this drive. It is important that capacitor (C1) beconnected within three feet ( meter) of the input terminals. Thecapacitor must be of the correct value and have the proper currentand voltage parameters (see list of components on page 11).It is recommended that the power supply leads be twisted together (6twists per foot).NOTE:If the power supply is grounded, it must only be groundedon the negative side or the short circuit protection will notoperate :The cable between the filter capacitor (C1) and the driveshould be twisted (six twists per foot). Maximum wirelength is three #16 AWG or larger Power Supply For A Single Drive Application11 Components for circuit shown in Figure :5 ampere or lower settingF13 amp.

8 , time delay, Bussman MDA-3 or equivalentF215 amp. very fast acting , Bussman GBB-15 orequivalentR15 ohm surge limiter, Phillips 2322-654-61508 ohm, 2 watts, 5%T1160 VA, Bicron Electronics BU216AS040D, SignalTransformer 80-2 or equivalentBR1 General Instrument GBPC3502 or equivalentC14700 f, amp. ripple current, 100 Vdc, UnitedChemiCon 36DA472F100AL2A or equivalent6 and 7 ampere settingsF16 amp. time delay, Bussman MDA-6 or equivalentF215 amp. very fast acting, Bussman GBB-15 orequivalentR14 ohm surge limiter,Phillips 2322-654-61408 ohm, 2 watts, 5%T1320 VA, Bicron Electronics BU233AS040D, SignalTransformer 80-4 or equivalentBR1 General Instrument GBPC3502 or equivalentC16800 f, amp. ripple current, 100 Vdc, UnitedChemi-Con 36DA682F100AD2A or equivalentSECTION 4: MECHANICAL SPECIFICATIONSSize(Inches).. H x W x D(mm)..111 H x 35 W x 146 pounds (680 grams) ELECTRICAL SPECIFICATIONSDC Input Vdc min.

9 , 75 Vdc Motor TableDrive Power Dissipation(Worst Case)..40 ENVIRONMENTAL +32 F to +122 F(0 C to +50 C) free air ambient, Natural Convec-tion. Maximum heat sink temperature of 158 F(70 C) must be maintained. Forced-air coolingmay be F to +167 F ..(-40 C to +75 C) max. ,000 feet (3048 m) MOTOR COMPATIBILITYM otor Electric M and KM SeriesFrame SizesM Series .. M061 (NEMA 23D) through M092 (NEMA 34)KM series .. KML060 (NEMA 23) through KML093 (NEMA 34)Number , 6, x Vdc Supply/I SettingExample:Vdc = 60 I Setting = 7R max. = x 60/7 = ohmsNOTE:Maximum resistance is total of motor plus : Do not use larger frame size motor than those listed, orthe drive may be damaged. If a larger frame size motor must beused, consult the factory for FOR USE WITH THESS2000MD7 translator /DRIVEP ower Supply CurrentMotorWindingConnectionCurrentSett ing(Am peres)Standstill(Amps. DC)Maximum(Amps. DC) supply currents shown are measured at the output of the rectifierbridge in Figure , M062 and M063 motors listed include LS, LE, CS, FC and FDversions.

10 M091, M092 and M093 motors include FC and FD versionswith 6 or 8 leads. Motors with windings other than those listed can beused as long as the current ratings listed on the motors are notexceeded. Consult the factory for recommendations concerning theuse of M111 and M112 frame size CURRENT SETTINGSThe proper current setting for each motor is shown on the individualtorque vs. speed curves. Use this current level to obtain the torqueshown. The access hole for the switches which set the motor currentlevel is located on the back of the unit (see Figure ). Switches 1through 6 are used to select the current level. Select the desiredoperating current by setting the appropriate switch to position 1 (ON).The OFF position is labeled "0". Only one switch should be ON. If two ormore switches are ON, the one which selects the highest current levelwill be the active switch. The switch settings are as follows:Position(amperes) * * * **Heat sinking is recommended at current settings of 4 amperes orhigher.