Example: marketing

Installation Manual

Installation Manual Installation and appliance setup installer : Leave this Manual with party responsible for use and operation. OWNER: Retain this Manual for future reference. NOTICE: DO NOT discard this Manual ! DANGER: If you smell gas: 1. Shut off gas to the appliance. 2. Extinguish any open flame. 3. If odor continues, keep away from the Model: appliance and immediately call your ODCOUG-36T/ODCOUG-42T gas supplier or fire department. ODCOUG-36PH/ODCOUG-42PH. ODCOUG-36PT/ODCOUG-42PT. ODCOUG-36/ODCOUG-42. WARNING: For outdoor use only. WARNING: Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance An LP-cylinder not connected for use shall not be stored in the vicinity of this or any other appliance WARNING!

qualified installer, service agency, or the gas supplier. WARNING: Improper installation, adjust-ment, alteration, service or maintenance can cause injury or property damage. Read the installation, operating and maintenance instructions thoroughly before installing or servicing this equipment. WARNING: If the information in this manual

Tags:

  Instructions, Installer

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Advertisement

Transcription of Installation Manual

1 Installation Manual Installation and appliance setup installer : Leave this Manual with party responsible for use and operation. OWNER: Retain this Manual for future reference. NOTICE: DO NOT discard this Manual ! DANGER: If you smell gas: 1. Shut off gas to the appliance. 2. Extinguish any open flame. 3. If odor continues, keep away from the Model: appliance and immediately call your ODCOUG-36T/ODCOUG-42T gas supplier or fire department. ODCOUG-36PH/ODCOUG-42PH. ODCOUG-36PT/ODCOUG-42PT. ODCOUG-36/ODCOUG-42. WARNING: For outdoor use only. WARNING: Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance An LP-cylinder not connected for use shall not be stored in the vicinity of this or any other appliance WARNING!

2 Risk Of Fire! WARNING: Improper Installation , adjustment, alteration, service or Do not install glass doors on this fireplace. maintenance can cause injury or property damage. Read Glass doors could cause overheating the Installation , operating and maintenance instructions of adjacent structures. thoroughly before installing or servicing this equipment. DANGER. Carbon Monoxide Hazard This appliance can produce carbon monoxide which has no odor. Using it in an enclosed space can kill you. Never use this appliance in an enclosed space such as a camper, tent, car or home Outdoor Lifestyles by Hearth & Home Technologies Inc. Courtyard Installation Manual 4608-901 Rev.

3 C 09/18 1. Safety Alert Key: DANGER! Indicates a hazardous situation which, if not avoided will result in death or serious injury. WARNING! Indicates a hazardous situation which, if not avoided could result in death or serious injury. CAUTION! Indicates a hazardous situation which, if not avoided, could result in minor or moderate injury. NOTICE: Used to address practices not related to personal injury. Table of Contents Standard Work 4 Appliance Preparation 1 Product Specific Information A. Securing and Leveling A. Appliance B. B. BTU 5 Electrical Information C. High Altitude A. Wiring D. Non-combustible Materials B. IntelliFire Pilot Ignition System E.

4 Combustible Materials C. Installing the F. Electrical 6 Gas Information G. A. Valve 2 Getting Started B. Gas A. Design and Installation C. Gas B. Tools and Supplies D. Fuel C. Inspect Appliance and E. High Altitude 3 Framing and Clearances 7 Finishing A. Appliance Dimension A. Facing B. Clearances to 8 Appliance setup C. Minimum A. Remove the Shipping D. Hearth Extension/Floor B. Clean the E. Stand-Alone C. Optional B. Wall Switch Control D. Verify Pilot G. Built-In E. Lava Rock Media/Glass H. Moisture 9 Reference Materials A. 2 Outdoor Lifestyles by Hearth & Home Technologies Inc. Courtyard Installation Manual 4608-901 Rev.

5 C 09/18. ATTENTION installer : Follow this Standard Work Checklist This standard work checklist is to be used by the installer in conjuction with, not instead of, the instructions contained in this Installation Manual . Customer: Date Installed: Lot/Address Location of Fireplace: installer : Model (circle one): ODCOUG-36T/ODCOUG-42T Dealer/Distributor Phone #. ODCOUG-36PH/ODCOUG-42PH Serial #: ODCOUG-36PT/ODCOUG-42PT. ODCOUG-36/ODCOUG-42. WARNING! Risk of Fire or Explosion! Failure to install fireplace acording to these instructions can lead to a fire or explosion. Fireplace Install YES IF NO, WHY? Wiring has been installed if necessary.

6 Verified clearances to combustibles. (Pg. 8). Fireplace is leveled and secured. (Pg. 15). Hearth extension size/height decided. ( ). Finishing Combustible materials not installed in non-combustible areas. Verified all clearances meet Installation Manual requirements. Mantels and wall projections comply with Installation Manual requirements. Hearth extension installed per Manual requirements. Fireplace Setup All packaging and protective materials removed. Refractory installed correctly. Firescreen installed properly. Manual bag and all of its contents are removed from the fireplace and given to the party responsible for use and operation.

7 Screen kit installed properly. (Optional). Hearth & Home Technologies recommends the following: Photographing the Installation and copying this checklist for your file. That this checklist remain visible at all times on the fireplace until the Installation is complete. Comments: Further description of the issues, who is responsible ( installer /Builder/Other Trades, etc.) and corrective action needed: Comments communicated to party responsible _____ by _____on _____. (Builder/Gen. Contractor) ( installer ) (Date). 4608-902 Rev A 3/18. Outdoor Lifestyles by Hearth & Home Technologies Inc. Courtyard Installation Manual 4608-901 Rev.

8 C 09/18 3. 1 Product Specific Information A. Appliance Certification D. Non-combustible Materials Specification Model: ODCOUG-36/ODCOUG-42. Laboratory: Underwriters Laboratories, Inc. (UL) Material which will not ignite and burn. Such Type: Outdoor Decorative Gas Appliances materials are those consisting entirely of steel, Standard: ANSI , CSA iron, brick, tile, concrete, slate, glass, plasters or any combination thereof. This product is listed to ANSI standards for Materials that are reported as passing ASTM E. Outdoor decorative Gas appliances and Gas 136, Standard Test Method for Behavior of Fired Appliances for Use at High Altitudes.

9 Materials in a Vertical Tube Furnace at 750 C. shall be considered non-combustible materials. Notice: This Installation must conform with local codes. In the absence of local codes you must E. Combustible Materials Specification comply with the National Fuel Gas Code, ANSI. latest edition in the and the CAN/ Materials made of or surfaced with wood, CGA B149 Installation codes in Canada. compressed paper, plant fibers, plastics, or other material that can ignite and burn, whether flame NOTE: This appliance is designed to be installed proofed or not, or plastered or unplastered shall and operate without exhaust venting or pipe.

10 Be considered combustible materials. B. BTU Specifications F. Electrical Codes Max Input Natural Notice: This appliance must be electrically wired Model Gas Type BTU Orifice Size and grounded in accordance with local codes or, in the absence of local codes, with National Natural 55,000 #27. Electric Code ANSI/NFPA 70-latest edition or ODCOUG-36/42. the Canadian Electrical Code CSA Propane 53,000 #45. A 110-120 Vac. circuit for this product must be protected with ground-fault circuit-interrupter protection, in compliance with the applicable C. High Altitude Installations electrical codes. Notice: If the heating value of the gas has been reduced, these rules do not apply.


Related search queries