1 Hearth & home Technologies DV3732, DV3732L, DV4236 Installation Manual 2355-980 Rev. J 11/16 Installation ManualInstallation and Appliance SetupINSTALLER: Leave this Manual with party responsible for use and : Retain this Manual for future : DO NOT discard this Manual !In the Commonwealth of Massachusetts Installation must be performed by a licensed plumber or gas fi Table of Contents for location of additional Commonwealth of Massachusetts appliance may be installed as an OEM Installation in manufactured home (USA only) or mobile home and must be installed in accordance with the manufacturer s instructions and the Manufactured home Construction and Safety Standard, Title 24 CFR, Part 3280 in the United States, or the Standard for Installation in Mobile Homes, CAN/CSA Z240 MH Series, in appliance is only for use with the type(s) of gas indicated on the rating plate.

4 Hearth & Home Technologies • DV3732, DV3732L, DV4236 Installation Manual • 2355-980 Rev. J • 11/16 B. Glass Specifi cations Hearth & Home Technologies appliances manufactured with tempered glass may be installed in hazardous lo …

Tags:

  Manual, Home

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Advertisement

Transcription of Installation Manual

1 1 Hearth & home Technologies DV3732, DV3732L, DV4236 Installation Manual 2355-980 Rev. J 11/16 Installation ManualInstallation and Appliance SetupINSTALLER: Leave this Manual with party responsible for use and : Retain this Manual for future : DO NOT discard this Manual !In the Commonwealth of Massachusetts Installation must be performed by a licensed plumber or gas fi Table of Contents for location of additional Commonwealth of Massachusetts appliance may be installed as an OEM Installation in manufactured home (USA only) or mobile home and must be installed in accordance with the manufacturer s instructions and the Manufactured home Construction and Safety Standard, Title 24 CFR, Part 3280 in the United States, or the Standard for Installation in Mobile Homes, CAN/CSA Z240 MH Series, in appliance is only for use with the type(s) of gas indicated on the rating plate.

2 This appliance is not convertible for use with other gases, unless a certifi ed kit is :DV3732DV3732 LDV4236 DANGERHOT GLASS WILL CAUSE NOT TOUCH GLASS UNTIL ALLOW CHILDREN TO TOUCH barrier designed to reduce the risk of burns from the hot viewing glass is provided with this appliance and shall be installed for the protection of children and other at-risk individuals. DO NOT store or use gasoline or other fl am-mable vapors and liquids in the vicinity of this or any other appliance. What to do if you smell gas - DO NOT try to light any DO NOT touch any electrical switch. DO NOT use any phone in your Leave the building Immediately call your gas supplier from a neighbor s phone. Follow the gas sup-plier s If you cannot reach your gas supplier, call the fi re department. Installation and service must be performed by a qualifi ed installer, service agency, or the gas : FIRE OR EXPLOSION HAZARDF ailure to follow safety warnings exactly could result in serious injury, death, or property damage.

3 Hearth & home Technologies DV3732, DV3732L, DV4236 Installation Manual 2355-980 Rev. J 11/162 Safety Alert Key: DANGER! Indicates a hazardous situation which, if not avoided will result in death or serious injury. WARNING! Indicates a hazardous situation which, if not avoided could result in death or serious injury. CAUTION! Indicates a hazardous situation which, if not avoided, could result in minor or moderate injury. NOTICE: Used to address practices not related to personal of ContentsInstallation Standard Work Checklist .. 31 Product Specifi c and Important Safety Information A. Appliance Certifi cation .. 4B. Glass Specifi cations .. 4C. BTU Specifi cations .. 4D. High Altitude Installations .. 4E. Non-Combustible Materials Specifi cation.. 4F. Combustible Materials Specifi cation .. 4G. Electrical Codes .. 4H. Requirements for the Commonwealth of Massachusetts.

4 52 Getting Started A. Design and Installation Considerations .. 6B. Good Faith Wall Surface/TV Guidelines .. 6C. Tools and Supplies Needed .. 6D. Inspect Appliance and Components .. 63 Framing and Clearances A. Appliance/Decorative Front Dimension Diagrams .. 7B. Clearances to Combustibles .. 10C. Constructing the Appliance Chase .. 114 Termination Location and Vent Information A. Vent Termination Minimum Clearances .. 12B. Chimney Diagram.. 13C. Approved Pipe .. 14D. Use of Elbows .. 15E. Measuring Standards .. 16F. Use of Flex Vent .. 16G. Vent Diagrams .. 175 Vent Clearances and Framing A. Pipe Clearances to Combustibles .. 29B. Wall Penetration Framing/Firestops .. 30C. Ceiling Firestop/Floor Penetration Framing .. 31D. Install Attic Insulation Shield .. 316 Appliance Preparation A. Vent Collar Preparation .. 32B. Securing and Leveling the Appliance .. 347 Venting and Chimneys A.

5 Assemble Vent Sections .. 35B. Assemble Slip Sections .. 36C. Secure the Vent Sections .. 37D. Disassemble Vent Sections .. 37E. Vertical Termination Requirements .. 38F. Horizontal Termination Requirements .. 398 Electrical Information A. General Information .. 41B. Wiring Requirements .. 419 Gas Information A. Fuel Conversion .. 44B. Gas Pressure .. 44C. Gas Connection .. 44D. High Altitude Installations .. 44E. Air Shutter Setting .. 4510 Finishing A. Facing Material .. 46B. Mantel and Wall Projections .. 47C. Decorative Front Dimensions for Finishing .. 48D. Elevated Hearth Systems .. 4911 Appliance Setup A. Fixed Glass Assembly .. 50B. Remove the Shipping Materials .. 50C. Clean the Appliance .. 50D. Install the Log Assembly.. 51E. Ember and Lava Rock Placement .. 53F. Install Decorative Front/Hood .. 5412 Reference Materials A. Vent Components Diagrams.

6 55B. Accessories .. 64 = Contains updated information. 3 Hearth & home Technologies DV3732, DV3732L, DV4236 Installation Manual 2355-980 Rev. J 11/16 Installation Standard Work ChecklistCustomer: Lot/Address:Model (circle one): DV3732 DV3732L DV4236 Date Installed: Location of Fireplace:Installer:Dealer/Distributor Phone # Serial #:Comments: Further description of the issues, who is responsible (Installer/ Builder/ Other Trades, etc) and corrective action needed _____Comments Communicated to party responsible _____ by _____on _____ (Builder / Gen. Contractor/) (Installer) (Date) Appliance Install YES IF NO, WHY?Veri ed that the chase is insulated and sealed. (Pg. 11) _____Veri ed clearances to combustibles. (Section 3) _____Fireplace is leveled and secured.

7 (Pg. 34) _____Venting/Chimney Section 7 (Pg. 35-40)Venting con guration complies to vent diagrams. _____Venting installed, locked and secured in place with proper clearance. _____Firestops installed. _____Attic insulation shield installed. _____Exterior wall/Roof ashing installed and sealed. _____Terminations installed and sealed. _____Electrical Section 8 (Pg. 41-43)Unswitched power (110-120 VAC) provided to the appliance. _____Switch wires properly installed. _____Gas Section 9 (Pg. 44-45)Proper appliance for fuel type. _____Was a conversion performed? _____Leak check performed and inlet pressure veri ed. _____Veri ed proper air shutter setting for Installation type. _____Finishing Section 10 (Pg. 46-49)Combustible materials not installed in non-combustible areas. _____Veri ed all clearances meet Installation Manual requirements. _____Mantels and wall projections comply with Installation Manual requirements.

8 _____Appliance Setup Section 11 (Pg. 50-54)All packaging and protective materials removed (inside & outside of appliance). _____Refractories, logs, media and embers installed correctly. _____Glass assembly installed and secured. _____Accessories installed properly. _____Mesh, doors, or decorative front properly installed. _____Manual bag and all of its contents are removed from inside/under the appliance and given to party responsible for use and operation. _____Started appliance and veri ed no gas leaks exist. _____2355-982 Rev. D 2/16 = Contains updated & home Technologies recommends the following: Photographing the Installation and copying this checklist for your le. That this checklist remain visible at all times on the appliance until the Installation is complete. This standard work checklist is to be used by the installer in conjunction with, not instead of, the instructions contained in this Installation !

9 Risk of Fire or Explosion! Failure to install appliance according to these instructions could lead to a re or INSTALLER:Follow this Standard Work ChecklistHearth & home Technologies DV3732, DV3732L, DV4236 Installation Manual 2355-980 Rev. J 11/164B. Glass Specifi cationsHearth & home Technologies appliances manufactured with tempered glass may be installed in hazardous lo-cations such as bathtub enclosures as defi ned by the Consumer Product Safety Commission (CPSC). The tempered glass has been tested and certifi ed to the re-quirements of ANSI and CPSC 16 CFR 1202 (Safety Glazing Certifi cation Council SGCC# 1595 and 1597. Architectural Testing, Inc. Reports and ).This statement is in compliance with CPSC 16 CFR Sec-tion Certifi cation and labeling requirements which refers to 15 Code (USC) 2063 stating ..Such certifi cate shall accompany the product or shall otherwise be furnished to any distributor or retailer to whom the product is delivered.

10 Some local building codes require the use of tempered glass with permanent marking in such locations. Glass meeting this requirement is available from the factory. Please contact your dealer or distributor to Appliance Certifi cationNOT INTENDED FOR USE AS A PRIMARY HEAT SOURCE. This appliance is tested and approved as either supplemen-tal room heat or as a decorative appliance. It should not be factored as primary heat in residential heating : This Installation must conform with local codes. In the absence of local codes you must comply with the National Fuel Gas Code, ANSI edition in the and the CAN/CGA B149 Installation Codes in 1 Product Specifi c and Important Safety Information C. BTU Specifi cationsE. Non-Combustible Materials Specifi cationMaterial which will not ignite and burn. Such materials are those consisting entirely of steel, iron, brick, tile, con-crete, slate, glass or plasters, or any combination that are reported as passing ASTM E 136, Standard Test Method for Behavior of Materials in a Vertical Tube Furnace at 750 C shall be considered non-combustible Combustible Materials Specifi cationMaterials made of or surfaced with wood, compressed pa-per, plant fi bers, plastics, or other material that can ignite and burn, whether fl ame proofed or not, or plastered or unplastered shall be considered combustible Electrical CodesNOTICE.