Example: quiz answers

Installation Manual - altEStore.com

SWWEBCONDM-IA-en-11 | 98-0051211 | Version : xxxxxSER: : xxxxxSER: Interface for SMA InvertersSMA SPEEDWIRE/WEBCONNECT DATA MODULEI nstallation ManualSMA Solar Technology AGTable of ContentsInstallation ManualSWWEBCONDM-IA-en-113 Table of Contents1 Information on this Document.. 52 Safety .. Intended Use .. Qualifications of Skilled Persons .. Safety Precautions .. operating Information.. 103 Scope of Delivery.. Order Option: Speedwire/Webconnect Data Module Pre-Installed in the Inverter.. Order Option: Speedwire/Webconnect Data Module as Retrofit Kit .. 114 Product Description .. Speedwire/Webconnect Data Module .. Type Label .. Cable Gland .. 175 Connection .. Device Overview .. Cable Requirements and Information on Routing .. Installing the Speedwire/Webconnect Data Module in the Inverter. Connecting the Speedwire/Webconnect Data Module .. 216 Commissioning.

Sunny Boy Sunny Tripower Windy Boy: SMA Solar Technology AG 2 Safety ... 10 SWWEBCONDM-IA-en-11 Installation Manual 2.4 Operating Information Selecting a Suitable Internet Tariff for Small Plants When using the Webconnect function, a constant Internet connection is required.

Tags:

  Manual, Operating, Installation, Installation manual, Sunny, Sunny boy sunny

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Advertisement

Transcription of Installation Manual - altEStore.com

1 SWWEBCONDM-IA-en-11 | 98-0051211 | Version : xxxxxSER: : xxxxxSER: Interface for SMA InvertersSMA SPEEDWIRE/WEBCONNECT DATA MODULEI nstallation ManualSMA Solar Technology AGTable of ContentsInstallation ManualSWWEBCONDM-IA-en-113 Table of Contents1 Information on this Document.. 52 Safety .. Intended Use .. Qualifications of Skilled Persons .. Safety Precautions .. operating Information.. 103 Scope of Delivery.. Order Option: Speedwire/Webconnect Data Module Pre-Installed in the Inverter.. Order Option: Speedwire/Webconnect Data Module as Retrofit Kit .. 114 Product Description .. Speedwire/Webconnect Data Module .. Type Label .. Cable Gland .. 175 Connection .. Device Overview .. Cable Requirements and Information on Routing .. Installing the Speedwire/Webconnect Data Module in the Inverter. Connecting the Speedwire/Webconnect Data Module .. 216 Commissioning.

2 Commissioning a Large Plant with Cluster Controller .. Commissioning a Small Plant.. Managing a Small Plant with sunny Explorer .. Functions and Parameter Settings in sunny Explorer .. Connection to sunny Explorer .. 24 Table of ContentsSMA Solar Technology AG4 SWWEBCONDM-IA-en-11 Installation Plant Registration in sunny Portal.. Registering a Small Plant in sunny Portal.. Registering a Large Plant with Cluster Controller in sunny Portal.. 267 Decommissioning.. Disassembling the Speedwire/Webconnect Data Module.. Disposing of the Speedwire/Webconnect Data Module .. 278 Troubleshooting .. 289 Technical Data .. 2910 Contact .. 30 SMA Solar Technology AG1 Information on this DocumentInstallation ManualSWWEBCONDM-IA-en-1151 Information on this DocumentValidityThis document is valid for device type " " with firmware version or GroupThis document is for skilled persons. Only skilled persons with appropriate qualification are allowed to perform the tasks set forth in this document (see Section "Qualifications of Skilled Persons", page 9).

3 Additional InformationLinks to additional information can be found at :Firmware Update with SD CardTechnical descriptionIndicates a hazardous situation which, if not avoided, will result in death or serious injuryIndicates a hazardous situation which, if not avoided, could result in death or serious injuryIndicates a hazardous situation which, if not avoided, could result in minor or moderate injuryIndicates a situation which, if not avoided, could result in property damageInformation that is important for a specific topic or goal, but is not safety-relevantIndicates an essential requirement for achieving a specific goalDesired resultA problem that might occurSymbolsDocument titleDocument typeSymbolExplanation bold>[But ton/Key]PV plantPlantSmall-scale PV plantSmall plantLarge-scale PV plantLarge plantSMA Cluster ControllerCluster ControllerSMA SpeedwireSpeedwireSMA Speedwire/Webconnect data moduleSpeedwire/Webconnect data moduleSMA Webconnect functionWebconnect functionSMA inverterInverter1 Information on this DocumentSMA Solar Technology AG6 SWWEBCONDM-IA-en-11 Installation ManualTypographyNomenclatureTypographyEx planationExample Display messages Elements of a user interface Connections Elements to be selected Elements to be entered The value can be read from the Energy field.

4 Select Settings. Enter the value 10 in the Minutes field. Connects several elements that are to be selected Select Settings > Date. Button or key to be selected or pressed Select [Next].Full designationDesignation in this documentACAlternating Current-DCDirect Current-DHCPD ynamic Host Configuration ProtocolProtocol for the dynamic assignment of IP configurationsESDE lectrostatic Discharge-ESSE lectronic Solar SwitchThe Electronic Solar Switch and the DC connectors form a DC load disconnect unitIPInternet Protocol-PICP roduct Identification CodeIdentification key for registration in sunny PortalRIDR egistration IdentifierRegistration key for registration in sunny PortalSMA Solar Technology AG1 Information on this DocumentInstallation ManualSWWEBCONDM-IA-en-117 AbbreviationsFiguresThe figures in this document may deviate slightly for inverter types sunny Tripower and Windy DesignationExplanation2 SafetySMA Solar Technology AG8 SWWEBCONDM-IA-en-11 Installation Manual2 Intended UseThe Speedwire/Webconnect data module is a Speedwire communication interface with Webconnect function for is

5 A cable-based type of communication based on the Ethernet standard and the communication protocol SMA Data2+. This enables inverter-optimised 10/100 Mbit data transmission between Speedwire devices in PV Webconnect function enables data transmission between the inverters of a small plant and the Internet portal sunny Portal. In sunny Portal, a maximum of four inverters can be combined in a sunny Portal Speedwire/Webconnect data module performs the following tasks: Set-up of a Speedwire network in small and large plants Direct data exchange with sunny Portal: In small plants via a router with Internet connection In large plants via the Cluster Controller Data exchange with sunny Explorer from version Speedwire/Webconnect data module is available as a retrofit kit or is pre-installed in the Speedwire/Webconnect data module may only be installed in the following inverters with at least firmware version.

6 SB 2500 TLST-21SB 3000 TLST-21SB 3000TL-21SB 3600TL-21SB 4000TL-21SB 5000TL-21 STP 8000TL-10 STP 10000TL-10 STP 12000TL-10 STP 15000TL-10 STP 15000 TLEE-10 STP 15000 TLHE-10 STP 17000TL-10 STP 20000 TLEE-10 STP 20000 TLHE-10WB 3000TL-21WB 3600TL-21WB 4000TL-21WB 5000TL-21 For information on the firmware update, refer to the Technical Description "Firmware Update with SD Card" at For safety reasons, it is not permitted to modify the product or install components that are not explicitly recommended or distributed by SMA Solar Technology AG for this BoySunny TripowerWindy BoySMA Solar Technology AG2 SafetyInstallation ManualSWWEBCONDM-IA-en-119 The enclosed documentation is an integral part of this product. Read and observe the documentation. Keep the documentation in a convenient place for future use the Speedwire/Webconnect data module in accordance with the specifications provided in the enclosed documentation.

7 Any other use may result in personal injury or property Qualifications of Skilled PersonsThe work described in this document must be performed by skilled persons only. Skilled persons must have the following qualifications: Training in the Installation and commissioning of electrical devices and plants Knowledge of how to deal with the dangers and risks associated with installing and using electrical devices and plants Knowledge of all applicable standards and directives Knowledge of how an inverter works and is operated Knowledge of and adherence to this document and all safety Safety PrecautionsElectric ShockLethal voltages are present in the conductive parts of the inverter. Prior to performing any work on the inverter, disconnect the inverter from any voltage sources on the AC and DC sides (see inverter Installation Manual ). Observe the waiting time to allow the capacitors to HazardsSome parts of the inverter enclosure can get hot during operation.

8 During operation, touch the inverter on the enclosure lid InfluencesWhen closed and with the ESS plugged in, the inverter has the degree of protection IP65. The inverter is thus protected against dust intrusion and water penetration. Dust intrusion and water penetration can damage the inverter. When the ESS is not plugged in, the inverter must be protected against dust and water. Firmly plug the ESS in again after performing any work on the DischargeBy touching electronic components, you can damage or even destroy the inverter through electrostatic discharge (ESD). Earth yourself before touching any inverter SafetySMA Solar Technology AG10 SWWEBCONDM-IA-en-11 Installation operating InformationSelecting a Suitable Internet Tariff for Small PlantsWhen using the Webconnect function, a constant Internet connection is required. Depending on the quality of the Internet connection, the transmission volume for an inverter is between 150 MB and 550 MB per month.

9 When using the plant overview in sunny Portal with live data display, there is an additional data volume of 600 kB per hour. SMA Solar Technology AG recommends using an Internet flat rate. Since there is a constant Internet connection to sunny Portal, time-based billing systems should be avoided. High costs could be Solar Technology AG3 Scope of DeliveryInstallation ManualSWWEBCONDM-IA-en-11113 Scope of Order Option: Speedwire/Webconnect Data Module Pre-Installed in the InverterCheck the scope of delivery for completeness and any visible external damage. Contact your specialist dealer if the delivery is incomplete or manualB1 Cable glandC1 Label with PIC and RID for registration of a small plant in sunny PortalFigure 1: Components included in delivery: Speedwire/Webconnect data module pre-installed in the Order Option: Speedwire/Webconnect Data Module as Retrofit KitCheck the scope of delivery for completeness and any visible external damage.

10 Contact your specialist dealer if the delivery is incomplete or Portal RegistrationPIC: xxxxxxxxxxxxxxxRID: XXxXXXABCDXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXABA1 Speedwire/Webconnect data moduleB1 Installation manualC1 Cable glandD2 Label with PIC and RID for registration of a small plant in sunny PortalFigure 2: Components included in delivery: Speedwire/Webconnect data module as retrofit kitItem Quantity DescriptionItem Quantity Description4 Product DescriptionSMA Solar Technology AG12 SWWEBCONDM-IA-en-11 Installation Manual4 Product Speedwire/Webconnect Data ModuleThe Speedwire/Webconnect data module is a Speedwire communication interface with Webconnect function for is a cable-based type of communication based on the Ethernet standard and the communication protocol SMA Data2+. This enables inverter-optimised 10/100 Mbit data transmission between Speedwire devices in PV Webconnect function enables data transmission between the inverters of a small plant and the Internet portal sunny Portal.