1 Heat & Glo TRUE-36-IFT, TRUE-42-IFT, TRUE-50-IFT Installation Manual 2461-980 Rev. T 11/21 Installation ManualInstallation and Appliance SetupINSTALLER: Leave this Manual with party responsible for use and : Retain this Manual for future : DO NOT discard this Manual !In the Commonwealth of Massachusetts Installation must be performed by a licensed plumber or gas Table of Contents for location of additional Commonwealth of Massachusetts :This appliance may be installed as an OEM Installation in manufactured home (USA only) or mobile home and must be installed in accordance with the manufacturer s instructions and the Manufactured home Construction and Safety Standard, Title 24 CFR, Part 3280 in the United States, or the Standard for Installation in mobile Homes, CAN/CSA Z240 MH Series, in appliance is only for use with the type(s) of gas indicated on the rati

installation in manufactured home (USA only) or mobile home and must be installed in accordance with the manufacturer’s instructions and the Manufactured Home Construction and Safety Standard,Title 24 CFR, Part 3280 in the United States, or the Standard for Installation in Mobile Homes, CAN/CSA Z240 MH Series, in Canada.

Tags:

  Manual, Installation, Mobile, Home, Installation manual, Mobile home

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of Installation Manual - downloads.hearthnhome.com

1 1 Heat & Glo TRUE-36-IFT, TRUE-42-IFT, TRUE-50-IFT Installation Manual 2461-980 Rev. T 11/21 Installation ManualInstallation and Appliance SetupINSTALLER: Leave this Manual with party responsible for use and : Retain this Manual for future : DO NOT discard this Manual !In the Commonwealth of Massachusetts Installation must be performed by a licensed plumber or gas Table of Contents for location of additional Commonwealth of Massachusetts :This appliance may be installed as an OEM Installation in manufactured home (USA only) or mobile home and must be installed in accordance with the manufacturer s instructions and the Manufactured home Construction and Safety Standard, Title 24 CFR, Part 3280 in the United States, or the Standard for Installation in mobile Homes, CAN/CSA Z240 MH Series, in appliance is only for use with the type(s) of gas indicated on the rating plate.

2 This appliance is not convertible for use with other gases, unless a certified kit is TRUE-36TG-IFTTRUE-36S-IFT TRUE-42G-IFTTRUE-42TG-IFTTRUE-42S-IFTTRU E-50TG-IFTTRUE-50S-IFT DO NOT store or use gasoline or other flam-mable vapors and liquids in the vicinity of this or any other appliance. What to do if you smell gas - DO NOT try to light any DO NOT touch any electrical switch. DO NOT use any phone in your Leave the building Immediately call your gas supplier from a neighbor s phone. Follow the gas sup-plier s If you cannot reach your gas supplier, call the fire department. Installation and service must be performed by a qualified installer, service agency, or the gas : FIRE OR EXPLOSION HAZARDF ailure to follow safety warnings exactly could result in serious injury, death, or property damage.

3 DANGERHOT GLASS WILL CAUSE NOT TOUCH GLASS UNTIL ALLOW CHILDREN TO TOUCH barrier designed to reduce the risk of burns from the hot viewing glass is provided with this appliance and must be installed for the protection of children and other at-risk demander un exemplaire en fran ais de ce manuel d Installation , visitez Heat & Glo TRUE-36-IFT, TRUE-42-IFT, TRUE-50-IFT Installation Manual 2461-980 Rev. T 11/212 Safety Alert Key: DANGER! Indicates a hazardous situation which, if not avoided will result in death or serious injury. WARNING! Indicates a hazardous situation which, if not avoided could result in death or serious injury.

4 CAUTION! Indicates a hazardous situation which, if not avoided, could result in minor or moderate injury. NOTICE: Used to address practices not related to personal : The term recommend or recommended does not indicate a requirement. It is a best practice suggested by Hearth & home Technologies . Table of ContentsInstallation Standard Work Checklist ..31 Product Specific and Important Safety Information A. Appliance Certification ..4B. Glass Specifications ..4C. BTU Specifications ..4D. High Altitude Installations ..4E. Non-Combustible Materials Specification.. 4F. Combustible Materials Specification.

5 4G. Electrical Codes ..4H. California ..4I. Requirements for the Commonwealth of Massachusetts ..52 Getting Started A. Design and Installation Considerations ..6B. Good Faith Wall Surface ..6C. Tools and Supplies Needed ..6D. Inspect Appliance and Components ..73 Framing and Clearances A. Appliance/Decorative Front Dimension Diagrams ..8B. Clearances to Combustibles ..13C. Constructing the Appliance Chase ..17D. Hearth Extension ..17E. Floor Protection ..184 Termination Location and Vent Information A. Vent Termination Minimum Clearances ..19B. Chimney Diagram.. 20C. Approved Pipe ..21D.

6 Use of Elbows ..21E. Measuring Standards ..22F. Vent Diagrams ..23G. PVLP-SLP and PVI-SLP-B Information ..305 Vent Clearances and Framing A. Pipe Clearances to Combustibles ..31B. Wall Penetration Framing/Firestops ..31C. Ceiling Firestop/Floor Penetration Framing ..32D. Install Attic Insulation Shield ..32E. Prepare for Heat Management ..336 Appliance Preparation A. Vent Collar Preparation ..34B. Securing and Leveling the Appliance ..35C. Installing Non-Combustible Facing Material ..367 Venting and Chimneys A. Assemble Vent Sections ..37B. Secure the Vent Sections ..38C. Disassemble Vent Sections.

7 38D. Vertical Termination Requirements ..39E. Horizontal Termination Requirements ..408 Electrical Information A. General Information ..41B. Wiring Requirements ..439 Gas Information A. Fuel Conversion ..44B. Gas Pressure ..44C. Gas Connection ..44D. High Altitude Installations ..44E. Air Shutter Setting ..4510 Finishing A. Facing Material ..46B. Finishing Templates ..47C. Mantel and Wall Projections ..49D. Decorative Front Dimensions for Finishing ..5111 Appliance Setup A. Fixed Glass Assembly ..52B. Remove the Shipping Materials ..54C. Clean the Appliance ..54D. Install Glass Refractory (TRUE-36G-IFT/TRUE-42G-IFT Only).

8 55E. Install Teco-Sil and Mystic Embers ..58F. Glowing Ember Placement ..59G. LED s ..59H. Install the Log Assembly ..60I. IntelliFire Touch Control System Setup ..66J. Install Decorative Front ..6612 Reference Materials A. Vent Components Diagrams ..67B. Accessories ..74 = Contains updated information. 3 Heat & Glo TRUE-36-IFT, TRUE-42-IFT, TRUE-50-IFT Installation Manual 2461-980 Rev. T 11/21 Installation Standard Work ChecklistCustomer: Lot/Address:Model (circle one): TRUE-36-IFT TRUE-50-IFT TRUE-42-IFT Date Installed: Location of Fireplace:Installer:Dealer/Distributor Phone # Serial #:Comments Communicated to party responsible _____ by _____on _____ (Builder / Gen.)

9 Contractor/) (Installer) (Date) = Contains updated & home Technologies recommends the following: Photographing the Installation and copying this checklist for your file. That this checklist remain visible at all times on the appliance until the Installation is complete. This standard work checklist is to be used by the installer in conjunction with, not instead of, the instructions contained in this Installation ! Risk of Fire or Explosion! Failure to install appliance according to these instructions could lead to a fire or INSTALLER:Follow this Standard Work ChecklistAppliance Install Information YES IF NO, WHY?

10 Verified clearances to combustibles requirements are maintained. (Pg. 13-16) _____ Verified that the chase is insulated and sealed. (Pg. 17) _____Verified mantel and wall clearance requirements are maintained. (Pg. 49-50) _____Verified hearth extension requirements are maintained. (Pg. 17) _____Verified appliance is leveled and secured. (Pg. 35) _____Verified required factory-supplied non-combustible board installed.